8.2 Installation of electronics box (E-box)
DANGER
Risk of life from incorrectly-installed safety equipment
For this reason:
S In an emergency it must be possible to shut down the engine rapidly and reliably in the engine room.
S It must be possible to reach the red emergency stop button on the E-box rapidly and securely.
S Keep access to the safety equipment/devices clear.
NOTICE
False alarms due to missing or inadequate grounding of the E-box
For this reason:
S Connect ground connection of the E-box with the ship potential and the engine block.
Recommendation: Mount the E-box close to the access (door/hatch) of the engine room.
S Attach the E-box vertically on a side wall of the engine room
S Ensure free space to open the hatch
S Maintain distance of H = 200 mm so that the plug can be connected to the E-box
Drilling pattern for bracket:
bore
. . . . . . . .
Diameter 8.5 mm (4x)
Dimension X
.
392.5 mm
Dimension Y
.
419 mm
To guarantee strain relief of the connecting
cables, the cables must be attached at
approximately H = 400 mm!
Read this manual carefully before starting any work!
This is particularly applicable to the chapter "General Safety Instructions"
and the respective safety instructions in the chapters.
Installation
57