Samsung MWR-WW10N Service Manual page 17

Wired remote controller
Hide thumbs Also See for MWR-WW10N:
Table of Contents

Advertisement

Feature expansion specification
■ Installation/Service mode
• Unavailable functions are marked inactive and they cannot be set.
• If communication initialization is needed after the setting, the system will reset automatically and communication
NOTE
will be initialized.
Step 1
Service Timer
Last Inspection
Installation Data
Quiet Mode
Automatic Time
Master/Slave
Wired Remote
Zone Selection
Temperature Unit
Temperature Sensor
Room Temperature
Indoor Zone
Option
Status Information
Step 2
Step 3
Service Call
Number
Cool/Heat
Selection
Standard
Temperature
Selection
Reference
Temperature
Calibration
Calibration Value
Central :
Normal Power :
Mode :
DHW Power :
DHW Mode :
Water Pump :
Indoor Zone
BSH :
BSH :
Flow sensor :
Inverter Pump :
EEV Step :
Thermostat 1 :
Thermostat 2 :
DHW Thermostat :
Description
16-digit phone number Input:
Blank, -, 0-9
Year, Month, Day
Year, Month, Day
Enable/Disable
Entry time to Exit time
Cool & Heat/Heat only
Master/Slave
Zone 1/Zone2
Water Outlet/Indoor
Celsius(°C) : 1℃/0.5℃/0.1℃
Fahrenheit(℉) : 1℉
Wired Remote Controller/External
Temperature Sensor
-9 to 40°C
-9 to 40°C
ON/OFF
ON/OFF
Heat/Cool/Auto
ON/OFF
Economic/Standard/
Power/Forced
ON/OFF
ON/OFF
ON/OFF
lpm
0%~100%
0~2000Step
ON/OFF
ON/OFF
ON/OFF
2-13
Features and Specifications
Default
-
-
-
Disable
PM 10:00 ~
AM 06:00
Cool & Heat
Master
Zone 1
Water Outlet
0.5℃
Fahrenheit(℉) : 1℉
Wired Remote
Controller
-
0℃
-
-
-
-
-
-
-
-
-
-
-
-
-
-