Do you have a question about the OL12D-D023B and is the answer not in the manual?
Questions and answers
Keith D And Cheryl A. D Shaffer
February 2, 2025
new owner and manual is not very detail
1 comments:
Mr. Anderson
February 10, 2025
The instruction manual for the ROWAN ELECTRIC APPLIANCE OL12D-D023B is available in the provided context. It includes sections on cautions, parameters, features, product description, digital display, operations, maintenance, and troubleshooting. You should refer to this manual for detailed information. If you need further assistance, you can contact customer service at 213-4467172 or 661-4358826.
This answer is automatically generated
ed zborovancik
March 17, 2025
how do you set the humidity level?
3 comments:
Mr. Anderson
March 17, 2025
To set the humidity level on the ROWAN ELECTRIC APPLIANCE OL12D-D023B, touch the humidity button to check the current environmental humidity. Touch the button again to set the humidity level. The available target humidity levels are 30%, 35%, 40%, 45%, 50%, 55%, 60%, 65%, 70%, 75%, and 80%. After 3 seconds, the system confirms the input value, exits the setting state, and returns to displaying the current humidity. Note that in drying mode, the target humidity cannot be changed.
This answer is automatically generated
ed zborovancik
March 17, 2025
@Mr. Anderson
ed zborovancik
March 17, 2025
when we touch humidity button it comes up 14 then back to 62
ed zborovancik
March 17, 2025
does machine cylce off or does it keep on running
1 comments:
Mr. Anderson
March 17, 2025
The ROWAN ELECTRIC APPLIANCE model OL12D-D023B operates in different modes:
- In Auto mode, the dehumidifier cycles on and off. When the environmental humidity is ≥ setting humidity +3%, the fan and compressor start working. When the humidity is ≤ setting humidity -3%, the compressor stops immediately, and the fan stops after a 30-second delay. - In Continuously drying mode, the dehumidifier keeps running without cycling off, and the humidity cannot be adjusted. - In Sleeping mode, the wind speed switches from high to low, and the indicators turn dark after 10 seconds of inactivity.
So, depending on the selected mode, the unit either cycles off (Auto mode) or keeps running (Continuously drying mode).
This answer is automatically generated
Melissa Hightower
April 1, 2025
We have had this product for about a year. We hadn't used it in a couple of months (was stored in cool/dry and cleaned/dried before storage). We plugged it in and the fan comes on and it runs, no errors, but it's not taking any water out of the room. It ran for 12 hrs with NO water in tank after that. When we realized that, we unplugged and the unit was warm to the touch. We can't find anything that addresses this in troubleshooting. (Note - we tried again today and after an hour still no water in tank.) What is wrong?
Summary of Contents for ROWAN ELECTRIC APPLIANCE OL12D-D023B
Page 1
INSTRUCTION MANUAL DEHUMIDIFIER Item NO:D4212B Applicable Model:OL12D-D023B Please keep this manual carefully for further reference! Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact the professional service for help.
CAUTIONS Please read the operating instructions carefully before using your dehumidifier for the first time. 1Install the unit on the flat and hard floor to diminish vibration or noise. 2.Never immerse the unit in water or other liquids. 3.Never operate the unit if the cable or other connector is damaged, or something abnormal may happen, please call customer service for help.
PARAMETERS OL12D-D023B Model No. AC115V/60Hz Power Supply 165W/1.8A@80℉,60%RH Power Consumption/Current 195W/2.0A@86℉,80%RH Power Consumption/Current 9Pints/Day@65℉,60%RH Dehumidify Capacity 13Pints/Day@80℉,60%RH Dehumidify Capacity Dehumidify Capacity 24Pints/Day @86℉,80%RH Noise ≤36dB(A) 2.0L Full Water Quantity R134a/3.70oz(105g) Refrigerant /Charge 10 x 8.5x 19.5 in Body Size Net Weight 10.4kg/23 lbs...
DIGITAL DISPLAY OPERATRIONS Power In the standby state, press the power button to turn on, the operation indicator light is on and the default fan speed is high, and the default humidity is 50%. In the power-on state, press the power button to turn off, the running indicator light goes off and the compressor stops immediately, and then the fan shuts down after 30 seconds’...
Page 8
● Continuously drying mode: The machine continues to run, but the humidity can not be adjusted. ● Sleeping mode: Touch the sleep button, the button lights up and the sleep function starts. After no operation in 10 seconds, all indicators turn dark gradually and the wind speed is automatically switched from high to low.
Page 9
Speed High wind - Low wind cycle, press button once to switch and then the corresponding indicator lights up. In continuously drying mode, sleeping mode and defrosting period, the wind speed can not be changed. Child-lock Press and hold the button for 3 seconds to turn on/off the child-lock function. Accessories 1.
●Empty the water tank. ●Put the water tank back in position. The dehumidifier automatically starts working again. MAINTENANCE PRECAUTIONS Do not remove the float from Ensure the water tank is in right the tank, otherwise the position when putting it back, dehumidifier can not start up.
Page 11
●Use a water hose to connect the water outlet. ●Pass the water hose through the cutting hole in the tank and put the tank back. For continuous drainage, the end of the hose should not be submerged in water to prevent it from being blocked or damaged. Spacing When the dehumidifier is in operation, make sure that the rear of the dehumidifier maintains a minimum spacing of 30cm as shown below.
Page 12
CLEANING ●Body Cleaning Use a soft and slightly moist cloth to clean the dehumidifier body. ●Filter Cleaning 2.Use a vacuum cleaner to gently 1.Remove the filter. absorb the dust on the surface. If the filter is very dirty, wash it with water and a soft detergent and dry it thoroughly afterwards.
TROUBLE SHOOTING FUNCTIONING TEMP. 41℉≤ Ambient Temp. ≤ 95℉ When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops. When 41℉≤ Ambient temp. ≤ 60.8℉, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running. 2.
Page 14
213-4467172 661-4358826 (8:30am - 5:30pm P.S.T.) SE REQUIERE PRUEBA DE COMPRA CON FECHA PARA SERVICIO BAJO GARANTÍA. Address : ROWAN ELECTRIC APPLIANCE LLC 28407 Ascent Way, Santa Clarita, CA 91350 Phone: 213-4467172 or 661-4358826...
Need help?
Do you have a question about the OL12D-D023B and is the answer not in the manual?
Questions and answers
new owner and manual is not very detail
The instruction manual for the ROWAN ELECTRIC APPLIANCE OL12D-D023B is available in the provided context. It includes sections on cautions, parameters, features, product description, digital display, operations, maintenance, and troubleshooting. You should refer to this manual for detailed information. If you need further assistance, you can contact customer service at 213-4467172 or 661-4358826.
This answer is automatically generated
how do you set the humidity level?
To set the humidity level on the ROWAN ELECTRIC APPLIANCE OL12D-D023B, touch the humidity button to check the current environmental humidity. Touch the button again to set the humidity level. The available target humidity levels are 30%, 35%, 40%, 45%, 50%, 55%, 60%, 65%, 70%, 75%, and 80%. After 3 seconds, the system confirms the input value, exits the setting state, and returns to displaying the current humidity. Note that in drying mode, the target humidity cannot be changed.
This answer is automatically generated
@Mr. Anderson
when we touch humidity button it comes up 14 then back to 62
does machine cylce off or does it keep on running
The ROWAN ELECTRIC APPLIANCE model OL12D-D023B operates in different modes:
- In Auto mode, the dehumidifier cycles on and off. When the environmental humidity is ≥ setting humidity +3%, the fan and compressor start working. When the humidity is ≤ setting humidity -3%, the compressor stops immediately, and the fan stops after a 30-second delay.
- In Continuously drying mode, the dehumidifier keeps running without cycling off, and the humidity cannot be adjusted.
- In Sleeping mode, the wind speed switches from high to low, and the indicators turn dark after 10 seconds of inactivity.
So, depending on the selected mode, the unit either cycles off (Auto mode) or keeps running (Continuously drying mode).
This answer is automatically generated
We have had this product for about a year. We hadn't used it in a couple of months (was stored in cool/dry and cleaned/dried before storage). We plugged it in and the fan comes on and it runs, no errors, but it's not taking any water out of the room. It ran for 12 hrs with NO water in tank after that. When we realized that, we unplugged and the unit was warm to the touch. We can't find anything that addresses this in troubleshooting. (Note - we tried again today and after an hour still no water in tank.) What is wrong?