Binding the Wireless thermostat and RF Receiver

3 BINDING THE WIRELESS THERMOSTAT AND RF RECEIVER
By default the thermostat is already linked to the RF receiver. For
these reason there is no need to perform binding procedure in
case it is only required one wireless thermostat at the installation.
The binding operation described below is required if:
Any of the system components (Room Thermostat or
RF Receiver) are replaced. Go to step 1.
The RF Receiver has incorrect or no binding data stored
(e.g. when pre-bound system pack components have been
mismatched). Go to step 1.
When adding a second wireless thermostat. Go to step 2.
?
N O T E
During the binding procedure keep approximately 1m distance between
the Room Thermostat and the RF Receiver.
1 Hold button on RF Receiver for 15 seconds in order to
remove all the configurations. At the end of the procedure,
LED will flash 0.5 seconds ON and 4 seconds OFF.
2 Hold button on RF Receiver for 5 seconds. Led will flash for
1 seconds ON and 1 second OFF.

4 COMMUNICATION LOSS

In case of alarm the LED on the RF Receiver flashes 150 ms
ON and 150 ms OFF. The following list shows which types of
communication fails makes the RF receiver to enter into alarm
state.
If there is a communications fault between the RF Receiver
and the Room Thermostat.
If there is a fault in communications between the YUTAKI
and RF Receiver.
If there is one Room Unit installed and communications is
lost with that zone.
If there is more than one Room Unit installed, as in multi-
zone systems for example, and communications is lost with
one zone.
If there is more than one Room Unit installed, as in multi-
zone systems for example, and communications is lost with
both zones.
7
PMML0582 rev.1 - 12/2021
Press here
LED
3 Reset stored data in room thermostat as explained in
"2.2.7 Reset to default".
4 From the reset stored data screen "CLr" put the thermostat
into Binding mode by pressing once ▲ button. Display will
show the word "COnt".
5 With both units in binding mode, pressing the off/standby
button on the room thermostat will bind them together.
6 If binding has been successful, after about 5 seconds the
room thermostat will come out of binding mode and go back
to off mode.
7 The LED on the RF receiver should be constantly ON
to indicate that the RF receiver is correctly linked with a
thermostat.
8 If binding is unsuccessful, LED will flash. In this case,
change the location of the room thermostat and repeat the
procedure.
9 In case that there are 2 room thermostats and thermostat
1 is already linked, LED will be stay ON even if binding is
unsuccessful for thermostat 2.
10 Perform this step in case started from step 1. Repeat
the procedure from step 2 to 7 to bind the second room
thermostat.
?
N O T E
Note that the RF receiver closes the binding window after 2 minutes
of inactivity.
The first binding is saved as Thermostat 1, and the second binding (if
necessary) is saved as Thermostat 2.
The selection of the zone in which Room thermostat will be used is
done at the Room thermostat menu in the YUTAKI LCD Controller
(PC-ARFH2E).
In case of alarm, check wireless thermostats and check also
YUTAKI LCD Controller (PC-ARFH2E) to determine reason of
alarm.
?
N O T E
LED also shows alarm in case of faulty RF receiver.