Summary of Contents for NU Skin RenuSpa iO

  • Page 1 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual File Name: Device Master Record (DMR) Formula: 0.0” length 6.0” width 4.0” height Dimensions and Colors PMS Black PMS CG9 PMS Color PMS Color CMYK PMS Color PMS Color PMS Color ™ USER’S MANUAL 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 1 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 1 9/5/23 15:56 9/5/23 15:56...
  • Page 2: Table Of Contents

    Description Replacement and Warranty Contraindications, Warnings, Precautions, and Adverse Reactions Patents Before You Begin Technical Description and Specifications Charging Your Nu Skin ® RenuSpa iO™ Symbols Using Your Nu Skin RenuSpa iO 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 2 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 2 9/5/23 15:56 9/5/23 15:56...
  • Page 3: System Contents

    SYSTEM CONTENTS Nu Skin ® RenuSpa iO™ device Quick Start Guide User Manual Nu Skin Conductive Gel Wireless Charger 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 1 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 1 9/5/23 15:56 9/5/23 15:56...
  • Page 4: Device Components

    DEVICE COMPONENTS Indicator Lights Power Button Metallic Nodes Battery Indicator 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 2 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 2 9/5/23 15:56 9/5/23 15:56...
  • Page 5: Intended Use

    Nu Skin RenuSpa iO emits an electrical current conducted to the skin through Nu Skin Conductive Gel. The patient is the intended operator of the Nu Skin RenuSpa iO device. All of Nu Skin RenuSpa iO functions are safe for patient use. Nu Skin RenuSpa iO device does not prevent, diagnose, or treat any medical condition.
  • Page 6: Contraindications, Warnings, Precautions, And Adverse Reactions

    CONTRAINDICATIONS, WARNINGS, PRECAUTIONS, AND ADVERSE REACTIONS Please read the following before using your Nu Skin ® RenuSpa iO. ™ CONTRAINDICATIONS FOR USE It is also not intended for: • Children The Nu Ski RenuSpa iO with Nu Skin ® Conductive Gel is •...
  • Page 7 Nu Skin ® Conductive Gel as it may irritate your skin. • Wear body piercings • Apply an ample amount of Nu Skin Conductive Gel to the skin. • Are chronically ill As needed, apply more Conductive Gel to all contact points.
  • Page 8 • Suspected or diagnosed heart disease • protective earth conductors • Tendencies to bleed internally • Using Nu Skin RenuSpa iO close (e.g., 1 m) to a shortwave or • Undergone a recent surgical procedure microwave therapy medical equipment may produce instability •...
  • Page 9 TEMPERATURE • Nu Skin ® RenuSpa iO™ is an electrical device. It may be subject to interference from other devices. Avoid using near strong Only charge the device in conditions between 41°F to 113°F sources of electric and magnetic fields (EMFs). This includes (5°C to 30°C).
  • Page 10: Charging Your Nu Skin® Renuspa Io

    CHARGING YOUR NU SKIN® RENUSPA iO™ • Fully charge your Nu Skin RenuSpa iO before your first use. • When the battery level is low the battery light will turn amber. • Connect the USB plug of the Nu Skin RenuSpa iO Wireless If the battery of the device is critically low, the battery light will Charger to a USB adapter.
  • Page 11 CONNECTING NU SKIN® WARNING RENUSPA iO™ TO THE • Only use the Nu Skin ® RenuSpa iO™ Wireless Charger for charging. NU SKIN VERA® APP • Check cabling and connection before each use. • Only use the Nu Skin RenuSpa iO Wireless Charger and a...
  • Page 12 2. Ensure your phone ’ s Bluetooth ®* is enabled. 3. Sign in to Nu Skin Vera. • Already have a Nu Skin account? Use it to sign in. • New to Nu Skin? Sign up—it ’ s easy! 4. Tap “Devices ” in the navigation bar.
  • Page 13: Using Your Nu Skin Renuspa Io

    YOUR NU SKIN RENUSPA iO DEVICE SESSION gel to your skin. Ensure the device is in contact with both your skin and Use Nu Skin RenuSpa iO with Nu Skin ® Conductive Gel on the gel for optimal use. clean skin. for the best results. Use the device 3 to 5 times a week per area.
  • Page 14 UPPER ARM USE THIGHS AND BUTTOCKS USE Lightly glide the device over the skin up toward your armpit and Lightly glide the device over the skin on the thighs up back down in slow circular movements, following the contours of and in toward the body’s center.
  • Page 15: Cleaning And Caring For Your Nu Skin Renuspa Io

    If the metallic nodes lose contact with your skin, the current will be interrupted, causing Nu Skin RenuSpa iO to pause, emit a tone, and the indicator lights to breathe. : A lack of serum or gel may cause a loss of conductivity.
  • Page 16 FACTORY RESET RESET BLUETOOTH® CONNECTION If you have problems pairing with Nu Skin Vera ® or if you need to To factory reset your Nu Skin ® RenuSpa iO: ™ unpair your device from your phone, conduct a Bluetooth 1. Disconnect from Nu Skin Vera ® within the app by navigating reset.
  • Page 17: Maintenance And Disposal

    MAINTENANCE AND DISPOSAL DEVICE DISPOSAL For routine maintenance of your Nu Skin ® RenuSpa iO, ™ please refer to the section titled “Cleaning and Caring for Your Nu Skin Dispose of your device properly according to local laws and RenuSpa iO Device. ”...
  • Page 18: Replacement And Warranty

    Nu Skin Support Services. Please do not ship damaged devices by air. PATENTS Nu Skin ® RenuSpa iO™ has US patents pending. 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 16 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 16 9/5/23 15:56 9/5/23 15:56...
  • Page 19: Technical Description And Specifications

    TECHNICAL DESCRIPTION AND SPECIFICATIONS NU SKIN® RENUSPA IO™ SPECIFICATIONS • Model: BS2RM • Device Dimensions: 130 X 35.6 X 74.7 X 74.0mm (5.1" × 2.9" × 2.9") • Device Weight: 190 grams (approx. 6.7 oz.) • Liquid Ingress Protection: • IP25—Protected against solid foreign objects > 12.5 mm Ø. Water protected from low-powered water jets •...
  • Page 20 (ohm—Ω) (micro-Amperes—µA, Avg.) 5 minutes Rated Supply Voltage: 3.6 VDC NU SKIN® RENUSPA iO™ WIRELESS CHARGER SPECIFICATIONS • Model: BS2RCA • Dimensions (unpackaged): 1159.0 × 22.6 × 74.0MM (45.6" × 0.9" × 2.9") • Weight: 74 grams (approx. 2.6 oz.) •...
  • Page 21 *Assuming (non-condensing) SAFETY FEATURES The Nu Skin RenuSpa iO was tested with the Nu Skin RenuSpa iO Wireless Charger. The Nu Skin RenuSpa iO system conforms to the listed standards. Conforms to EN IEC/UL: 60601-1, 60601-1-2, 60601-1-11, 60601-2-10, 62133-2, 62366-1 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 19...
  • Page 22 encouraged to try to correct the interference by one or more of the following measures: This device complies with part 15 of the FCC Rules. Operation • Reorient or relocate the receiving antenna. is subject to the following two conditions: (1) This device may •...
  • Page 23 ELECTROMAGNETIC COMPATIBILITY (EMC) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the in- Avoid using near strong sources of EMF like hair dryers and structions, may cause harmful interference to radio communi- electric shavers in-use.
  • Page 24 EMISSIONS AND IMMUNITY TEST LEVELS TEST STANDARD TEST LEVEL Clause 8.10 Test Frequency: 2 450 Band: 2 400 – 2 570 Conducted Disturbances (con- Class B Group 1 Bluetooth, WLAN, 802.11 b/g/n, ducted EMISSIONS) Minimum and Maximum Rated Voltage RFID 2450, LTE Band 7 CISPR 11 Pulse modulation: 217Hz Max Power: 2W...
  • Page 25 REPORTING ADVERSE EVENTS MedWatch is the Food and Drug Administration ’ s (FDA) Submitting Adverse Event Reports to FDA program for reporting serious reactions,product quality problems, Use one of the methods below to submit voluntary adverse therapeutic inequivalence/failure, and product use errors with event reports to the FDA: humanmedical products, including drugs, biologic products, Report Online at www.accessdata.fda.gov/scripts/medwatch/...
  • Page 26: Symbols

    Symbol Symbol Symbol Definition Direct Current Warning Interference may occur in the vicinity of equipment marked with this symbol for non-ionizing radiation Relative Humidity Limits Manufacturing Information Temperature Limits Class III Protection Against Electric Shock Follow instructions for use Serial Number Type BF Applied Parts—Stimulator is a Type BF Applied Part Batch Code...
  • Page 27 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 25 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 25 9/5/23 15:56 9/5/23 15:56...
  • Page 28 MEDICAL—GENERAL MEDICAL EQUIPMENT AS ©2023 NSE PRODUCTS, INC. TO ELECTRICAL SHOCK, FIRE AND MECHANICAL 75 WEST CENTER STREET, PROVO, UT 84601 HAZARDS ONLY IN ACCORDANCE WITH AAMI xxxxx NUSKIN .COM 1-800-487-1000 ES60601 - 1:2005/(R)2012 and AI:2012/(R)2012 01 002589 94515584/3 and A2:2021) 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 26 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 26 9/5/23 15:56...