4.1
Test Equipment Required for Alignment
Test Equipment
1. Standard Signal
Generator (SSG)
2. Power Meter
3. Deviation Meter
4. Digital Volt Meter
(DVM)
5. Oscilloscope
6. High Sensitivity Frequency
Counter
7. Ammeter
8. AF Volt Meter (AF VM)
9. Audio Generator (AG)
10. Distortion Meter
11. 8ohm Dummy Load
12. Regulated Power Supply
ANT cable (E30-3418-25)
Modify the ANT cable as shown below.
Solder the ANT cable to the ANT terminal on the TX-RX unit.
TX-RX unit
ANT cable
1-26 (No.RA066<Rev.001>)
SECTION 4

ADJUSTMENT

Frequency Range
Modulation
Output
Input Impedance
Operation Frequency
Measuring Range
Frequency Range
Measuring Range
Input Impedance
Frequency Range
Frequency Stability
Frequency Range
Voltage Range
Frequency Range
Output
Capability
Input Level
Cut
GND
ANT terminal
Major Specifications
100 to 900MHz
Frequency modulation and external modulation
-127dBm/0.1V to greater than -47dBm/1mV
50ohm
100 to 900MHz
Vicinity of 10W
100 to 900MHz
10mV to 10V DC
High input impedance for minimum circuit loading
DC through 30MHz
10Hz to 1000MHz
0.2ppm or less
5A
50Hz to 10kHz
1mV to 10V
50Hz to 5kHz or more
0 to 1V
3% or less at 1kHz
50mV to 10Vrms
Approx. 8ohm, 3W
0V to 10V, approx. 3A
Useful if ammeter equipped
Battery Jig (W3F-0385-00)
Connect the power cable properly between the battery jig
installed in the transceiver and the power supply, and be sure
output voltage and the power supply polarity prior to switching
the power supply ON, otherwise over voltage and reverse
connection may damage the transceiver, or the power supply or
both.
Red: +Terminal
Black: - Terminal