Table 1-1. Specifications (Continued)
LANIC at AUI Connector:
AUI signalling conforms to IEEE 802.3
CO not driven
VP +12V +/-6%
@
0.5A; overcurrent protected
@
1.2A maximum
Interframe spacing
=
9.6 usec minimum
Thin MAU at AUI Connector:
AUI signalling conforms to IEEE 802.3
CO terminated but unused
Operating voltage:
8.0V to 13.50V at 360mA maximum
ThinMAU at Coaxial Cable:
Coax signalling compatible with IEEE 802.3 recommended
signalling levels
Receiver based collision detection
Compatible with any coaxial cable meeting IEEE 802.3
type 10, base 2 physical specifications