Compressed Air; Air Purity Classes (Iso 8573-1); Setting The Sealing Air - Jäger ZS62-H650.02 S19W2/2 Manual

High frequency spindle
Table of Contents

Advertisement

For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
[
 25]" section.
}
Item no. 13404080, Revision 01
8.4

Compressed air

8.4.1

Air purity classes (ISO 8573-1)

Solid impurities
Water content
Total oil content
8.4.2

Setting the sealing air

The adjustment value for the sealing air depends on the hose diameter and
length.
Ü
Hose diameter: DN 4
Ü
The setting value can be found in the following diagram.
Ü
To ensure effective control, turn on the sealing air and cooling when turn-
ing on the machine. This protects the HF spindle even when it is stationary.
Lowest sealing air supply
Medium sealing air supply
Highest sealing air supply
Installation
Class 3
Filter grade at least 5 µm for solids
Class 4
Max. pressure dew point +3 °C
Class 3
Max. oil content 1 mg/m
Dry machining
Machining with spray water
Machining with hose water
3
25 ( 40 )

Advertisement

Table of Contents
loading

Table of Contents