GENERATOR
*Stand-by single-phase power
*PRP single-phase power
*Stand-by single-phase power
*PRP single-phase power
Frequency
Cos ϕ
Output powers according to ISO 8528-1
*
ALTERNATOR
Type
Insulation class
ENGINE
Make / Model
Type / Cooling system
Cylinder / Displacement
*Stand by net power
*PRP net power
Speed
Fuel consumption (75% of PRP)
Engine oil capacity (max)
Starter
Powers according to
*
ISO 3046-1
GENERAL SPECIFICATIONS
Battery charge
Tank capacity
Running time (75% of PRP)
Protection
*Dimensions max. on base Lxlxh (mm)
*Weight (dry)
Acoustic power LwA (pressure LpA)
* Dimensions and weight without trolley/trailer.
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It's admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ATTENTION:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (L
A) - Measure Unit dB(A):
w
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A):
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(L
A) of 95 dB(A)
w
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
PLEASE NOTE:
the symbol
according to 2000/14/CE directive.
GE S-5000 BBM
self-excited, self-regulated, brushless
recoil (AA)
ACOUSTIC POWER LEVEL
it stands for acoustic noise released in a certain delay of time. This is not
it measures the pressure originated by sound waves emission. Its value changes
when with acoustic noise values, indicates that the device respects noise emission limits
2000 / 14 / CE
5 kVA (4.4 kW)/ 230 V / 21.7 A
4 kVA (3.6 kW)/ 230 V / 17.4 A
5 kVA (4.5 kW) / 115V / 43.4 A
4 kVA (3.6 kW)/ 115 V / 34.8 A
50 Hz
0.9
single-phase, synchronous
B&S XR1450
Gasoline 4-Stroke / air
1 / 306 cm³
6.5 kW (8.8 HP)
5.9 kW (8 HP)
3000 rpm
1.9 l/h
1.1 l
12V - 10A
20 l
10.5 h
IP 23
770x520x650
76 kg (AA) / 86 kg (AE)
98 dB(A) (73 dB(A) @ 7 m)
OUTPUT
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
TECHNICAL DATE
GE S-5000 BBM AVR
self-excited, self-regulated
H
M
1.5.1
electric (AE)
Need help?
Do you have a question about the GE S-5000 HBM and is the answer not in the manual?