Do you have a question about the HPM-SRSDE and is the answer not in the manual?
Questions and answers
Summary of Contents for BCM Advanced Research HPM-SRSDE
Page 1
HPM-SRSDE Intel® dual 4th Gen. Xeon® Scalable Processor Proprietary Server Board with Intel® C741 Chipset and IPMI2.0 User’s Manual Ed –07 September 2023 Part No: E2047P4S000R...
Page 2
We assume no responsibility or liability for the use of the described product(s), conveys no license or title under any patent, copyright, or masks work rights to these products, and makes no representations or warranties that 2 HPM-SRSDE User’s Manual...
Page 3
For the most frequently asked questions, you can easily find answers in your product documentation. These answers are normally a lot more detailed than the ones we can give over the phone. So please consult the user’s manual first. HPM-SRSDE User’s Manual...
Page 4
A product returned without proof of the purchase date is not eligible for warranty service. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer. 4 HPM-SRSDE User’s Manual...
électrostatique. Placez tous les composants électroniques sur une surface antistatique ou dans un sac antistatique quand ils ne sont pas dans le châssis. Risque d'explosion si la batterie est remplacée par un type incorrect. Jetez les piles usagées selon les instructions HPM-SRSDE User’s Manual...
Dispose of the battery in accordance with local regulations and instructions from your service provider. 1.2 Packing List 1 x HPM-SRSDE motherboard ⚫ 1 x I/O Shield ⚫...
We strongly recommend that you study this manual carefully before attempting to set up HPM-SRSDE or change the standard configurations. Whilst all the necessary information is available in this manual we would recommend that unless you are confident, you contact your supplier for guidance.
Slot 2, PCIe Gen5 x16 from 1st CPU PCIe Slot 3, PCIe Gen5 x16 from 2nd CPU Slot 4, PCIe Gen5 x16 from 1st CPU Slot 5, PCIe Gen5 x16 from 2nd CPU Slot 6, PCIe Gen5 x16 from 1st CPU HPM-SRSDE User’s Manual 13...
Page 14
2x USB 2.0 type A receptacle 2 x USB 2.0 ports (1 x USB 2.0 2.54mm pitch Box Header) Pin definition: USB 2.0 Pin 1 Pin 2 USB0- Pin 3 Pin 4 USB1- USB0+ Pin 5 Pin 6 USB1+ 14 HPM-SRSDE User’s Manual...
Page 15
Notes: LAN2-X ACT LED, “X” means the max number of Ethernet ports. RTC Battery 1 x Horizontal Socket Type CMOS Battery Holder with CR2450 Clear CMOS 1 x Clear CMOS header (1 x 2.0 mm pitch Header) HPM-SRSDE User’s Manual 15...
Page 16
H/W: ATX power well design only Power Mode BMC: AT (Default) 0 °C to 50 °C to support up to 250W TDP CPU Operating Temp. 0 °C to 40 °C to support up to 270W TDP CPU 16 HPM-SRSDE User’s Manual...
Page 17
Reference ISTA 2A, Method : IEC-60068-2-32 Test:Ed Test Ea : Drop Test Drop Test 1 Test phase : One corner, three edges, six faces 2 Test high : 96.5cm 3 Package weight : 5Kg 4 Test drawing HPM-SRSDE User’s Manual 17...
Page 18
Windows Server IoT 2019 with VT-d disabled. OS Information Windows Server IoT 2022. Linux : Ubuntu 20.04 LTS or later Red Hat Enterprise Linux (RHEL) 8.2 and later Note: Specifications are subject to change without notice. 18 HPM-SRSDE User’s Manual...
HPM-SRSDE User’s Manual 1.6 Architecture Overview—Block Diagram The following block diagram shows the architecture and main components of HPM-SRSDE. 20 HPM-SRSDE User’s Manual...
SATA or PCIE select 3 x 1 header, pitch 2.00mm Connectors Label Function Note SYS_FAN1-6 System fan connector 1-6 4 x 1 wafer, pitch 2.54mm CPU_FAN1-2 CPU fan connector 1-2 4 x 1 wafer, pitch 2.54mm HPM-SRSDE User’s Manual 23...
Page 24
1 x4 NVMe interface) 3 x SlimSAS 8i connector for 6 x4 SLIMSAS1-3 NVMe JRAID_KEY1 VROC Header 4 x 1 header, pitch 2.00mm DIMM1-12 12 x DDR5 RDIMM socket JVR_PRG1 SMBUS VR connector 3 x 1 header, pitch 2.54mm 24 HPM-SRSDE User’s Manual...
Page 25
CPU PCIE HP SMB connector 5 x 1 header, pitch 2.00mm JAUDIO1 AZALIA connector 6 x 2 header, pitch 2.00mm M2(NGFF)1 M.2 M-Key PCIe 5.0 x4 NVMe SSD JCPLD_JTAG1 CPLD JTAG header 5 x 2 header, pitch 2.54mm HPM-SRSDE User’s Manual 25...
HPM-SRSDE User’s Manual 2.3.9 System fan connector 2 (SYS_FAN2) Signal SYS_PWM2 FAN_TACH2 +12V 2.3.10 System fan connector 3 (SYS_FAN3) Signal SYS_PWM3 FAN_TACH3 +12V 30 HPM-SRSDE User’s Manual...
User’s Manual 2.3.11 System fan connector 4 (SYS_FAN4) Signal SYS_PWM4 FAN_TACH4 +12V 2.3.12 System fan connector 5 (SYS_FAN5) Signal +12V FAN_TACH5 SYS_PWM5 HPM-SRSDE User’s Manual 31...
HPM-SRSDE User’s Manual 2.3.13 System fan connector 6 (SYS_FAN6) Signal +12V FAN_TACH6 SYS_PWM6 2.3.14 CPU fan connector 1 (CPU_FAN1) Signal +12V FAN_TACH0 CPU0_PWM 32 HPM-SRSDE User’s Manual...
User’s Manual 2.3.19 Serial General Purpose I/O connector (JSGPIO1) Signal PIN PIN Signal SGPIO_DATAOUT SGPIO_LOAD SGPIO_CLOCK 2.3.20 ATX 12V power connector 1 (ATX12V1) Signal Signal +12V +12V +12V +12V HPM-SRSDE User’s Manual 35...
The processor assembly contains the Intel Xeon SP with carrier and CPU cooler. -1x Intel 4 Xeon SP (MCC SKU) -1x E1B CPU Carrier (In the HPM-SRSDE package) -1x Cooler module (P/N:BCC-FAN-467-01R) Please ensure the carrier model on the CPU is consistent with the carrier silkscreen.
Page 46
CPU1: Make sure the lever on the carrier is on the same side as the fan. CPU2: Make sure the lever on the carrier is on a different side than the fan. (Only applicable to HPM-SRSDE and Cooler BCC-FAN-467-01R.) Note: The Thermal grease must be pre-applied on the heatsink before installation.
Page 47
User’s Manual Press down to fix. Press down to fix. Here is the lever CPU1 HPM-SRSDE User’s Manual 47...
Page 48
★ The cooler module with CPU pin1 must be aligned with the CPU socket pin1 mark, and the direction cannot be changed at will, or it may cause the CPU to damage after pressing. CPU Socket Cooler Module with CPU Upside down Pin1 48 HPM-SRSDE User’s Manual...
Page 49
User’s Manual Pin 1 ▲Figure A ▲Figure B ▲Figure C HPM-SRSDE User’s Manual 49...
Page 50
Install the cooling fan and holder on the cooler module and tighten two locking screws (T30) on the top of the fan holder. Note: The 4U cooler’s fan for Xeon SP dual sockets is facing the opposite side of Edge I/O. 50 HPM-SRSDE User’s Manual...
Page 51
User’s Manual Connect the cooling fan connector to the fan header labeled for the CPU on the motherboard. HPM-SRSDE User’s Manual 51...
If the message disappears before you respond and you still wish to enter Setup, restart the system to try again by turning it OFF then ON or pressing the "RESET" button on the system case. You may also restart by simultaneously pressing <Ctrl>, <Alt>, and <Delete> keys. HPM-SRSDE User’s Manual 53...
Note: Some of the navigation keys differ from one screen to another. • To Display a Sub Menu Use the arrow keys to move the cursor to the sub menu you want. Then press <Enter>. A “➢” pointer marks all sub menus. 54 HPM-SRSDE User’s Manual...
BIOS Vendor and your systems manufacturer to provide the absolute maximum performance and reliability. Even a seemingly small change to the chipset setup has the potential for causing you to use the override. HPM-SRSDE User’s Manual 55...
Use the system time option to set the system time. Manually enter the hours, minutes and seconds. Note: The BIOS setup screens shown in this chapter are for reference purposes only, and may not exactly match what you see on your screen. 56 HPM-SRSDE User’s Manual...
3.6.2.1 Trusted Computing Item Options Description Enables or Disables BIOS support for security device. Disable, Security Device Support O.S. will not show Security Device. TCG EFI protocol Enable[Default] and INT1A interface will not be available. HPM-SRSDE User’s Manual 57...
Enable ACPI Auto Disabled[Default] Enables or Disables BIOS ACPI Auto Configuration. Configuration Enabled Enables or Disables System ability to Hibernate Disabled Enable Hibernation (OS/S4 Sleep State). This option may not be effective Enabled[Default] with some operating systems. 58 HPM-SRSDE User’s Manual...
User’s Manual 3.6.2.3 AST2600 Super IO Configuration Item Description Serial Port 1 Configuration Set Parameters of Serial Port 1 (COMA). Serial Port 2 Configuration Set Parameters of Serial Port 2 (COMB). 3.6.2.3.1 Serial Port 1 Configuration HPM-SRSDE User’s Manual 59...
Item Option Description Enabled[Default], Serial Port Enable or Disable Serial Port (COM). Disabled 3.6.2.3.2 Serial Port 2 Configuration Item Option Description Enabled[Default], Serial Port Enable or Disable Serial Port (COM). Disabled 3.6.2.4 Serial Port Console Redirection 60 HPM-SRSDE User’s Manual...
Page 62
Enable or Disable Option ROM execution for Slot#5 Empty Disabled selected Slot. Enabled[Default], Enable or Disable Option ROM execution for Slot#6 Empty Disabled selected Slot. Enabled[Default], Enable or Disable Option ROM execution for Slot#7 Empty Disabled selected Slot. 62 HPM-SRSDE User’s Manual...
Maximum time the device will take before it properly reports itself to the Host Controller. Auto[Default] ‘Auto’ uses default value: for a Root port it is Device power-up delay Manual 100 ms, for a Hub port the delay is taken from Hub descriptor. HPM-SRSDE User’s Manual 63...
Optical drives are emulated as ‘CDROM’, drives with no media will be Hard Disk CD-ROM emulated according to a drive type. 3.6.2.7 Network Stack Configuration Item Options Description Enabled Network Stack Enable/Disable UEFI Network Stack. Disabled[Default] 3.6.2.8 NVMe Configuration 64 HPM-SRSDE User’s Manual...
User’s Manual 3.6.3.1.2 SATA And RST Configuration 3.6.3.1.2.1 Controller 2 SATA And RST Configuration HPM-SRSDE User’s Manual 71...
Page 72
SATA Port 2(Mini SAS SATA 3) Enable or Disable SATA Port. Enabled[Default] If enabled for any of ports Staggerred Disabled[Default] Spin Up Device Spin Up will be performed and only the Enabled drives which have this option enabled will 72 HPM-SRSDE User’s Manual...
Page 73
Otherwise all drives spin up at boot. Hard Disk Drive[Default] Identify the SATA port is connected to SATA Device Type Solid State Drive Solid State Drive or Hard Disk Drive. 3.6.3.1.2.2 Software Feature Mask Configuration for Controller 2 HPM-SRSDE User’s Manual 73...
USB overcurrent is not Enabled[Default] disabled, USB DbC does not work. Selectively Enable/Disable the corresponding USB Disable[Default] USB Port Disable Override port from reporting a Device Connection to the Select Per-Pin controller. 74 HPM-SRSDE User’s Manual...
Server ME Configuration Item Option Description The altitude of the platform location above the sea level, expressed in meters. The hex number is decoded as 2’s Altitude 8000 complement signed integer. Provide the 8000h value if the HPM-SRSDE User’s Manual 75...
3.6.4.1.1 Per-Socket Configuration 3.6.4.1.1.1 CPU Socket 0 Configuration Item Option Description 0: Enable all cores. FFFFFFFFFFFFFFFF: Disable all cores. NOTE: AT least one core per CPU must be Disable Bitmap: enabled. Disabling all cores is an invalid configuration. HPM-SRSDE User’s Manual 77...
NOTE: AT least one core per CPU must be Disable Bitmap: enabled. Disabling all cores is an invalid configuration. 3.6.4.2 Memory Configuration Item Option Description Auto[Default] Maximum Memory Frequency Selections in Memory Frequency 3200 MT/s. If Enforce POR is disabled, user will 78 HPM-SRSDE User’s Manual...
User’s Manual 3600 be able to run at higher frequencies than 4000 the memory suppot (limited by processor 4400 support). Do not select Reserved. 4800 5200 5600 3.6.4.2.1 Memory Topology 3.6.4.3 IIO Configuration HPM-SRSDE User’s Manual 79...
Selects PCIe port Bifurcation for selected x2x2x2x2x_x8 IOU0 PCIe Slot6 x16 x2x2x2x2x4x4 slot(s) Port Format: xDxCxBxA The port x2x2x4x2x2x4 can further be x2x2. x4x2x2x2x2x4 x2x2x2x2x2x2x4 x_x8x4x2x2 x4x4x4x2x2 x_x8x2x2x2x2 x2x2x4x4x2x2 x4x2x2x4x2x2 x4x4x2x2x2x2 x2x2x2x2x4x2x2 x2x2x4x2x2x2x2 x4x2x2x2x2x2x2 x2x2x2x2x2x2x2x2 80 HPM-SRSDE User’s Manual...
Page 81
Auto x4x4x4x4[Default] Selects PCIe port Bifurcation for selected IOU3 PCIe x4x4x_x8 slot(s) Port Format: xDxCxBxA The port x550/M.2/SAS1 x_x8x4x4 x_x8x_x8 can further be x2x2. x_x_x_x16 HPM-SRSDE User’s Manual 81...
Page 82
Auto: Auto select Force CXL: There is no training discovery, the attached device must also supports this mode. Select PCIe Subsystem Mode for Gen5 Port 2 Subsystem Mode Protocol Auto Negotiation[Default] selected slot(s) Gen4: Gen4 controller 82 HPM-SRSDE User’s Manual...
Page 83
Applies to root ports only. Enabled Sck0 RP NonFatal No[Default] Uncorrectable Err interrupt on a non-fatal error. Applies to root ports only. Enabled Sck0 RP Fatal No[Default] Uncorrectable Err MSI/INTx interrupt on fatal errors. HPM-SRSDE User’s Manual 83...
Gen 5 (32 GT/s) -6.0 dB[Default] De-Emphais control (LNKCON2[6]) for this PCIe PCI-E Port DeEmphasis -3.5 dB port. Disabled[Default] This option can disable ASPM support in a PCIe PCI-E ASPM Support root port. ‘Auto’ keeps hardware default. Auto 84 HPM-SRSDE User’s Manual...
-6.0 dB[Default] De-Emphais control (LNKCON2[6]) for this PCIe PCI-E Port DeEmphasis -3.5 dB port. 128B Configure Max Payload Size Supported in PCIe 256B Device Capabilities register. ‘Auto’ keeps hardware PCI-E Port MPSS 512B default. Auto[Default] HPM-SRSDE User’s Manual 85...
Description Auto x4x4x4x4 x4x4x_x8 x_x8x4x4 x_x8x_x8 x_x_x_x16[Default] Selects PCIe port Bifurcation for selected x2x2x4x_x8 IOU0 PCIe Slot7 x16 x4x2x2x_x8 slot(s) Port Format: xDxCxBxA The port x_x8x2x2x4 can further be x2x2. x2x2x4x4x4 x4x2x2x4x4 x4x4x2x2x4 x2x2x2x2x_x8 x2x2x2x2x4x4 x2x2x4x2x2x4 86 HPM-SRSDE User’s Manual...
Page 87
Selects PCIe port Bifurcation for selected x2x2x4x4x4 IOU2 PCIe Slot3 x16 x4x2x2x4x4 slot(s) Port Format: xDxCxBxA The port x4x4x2x2x4 can further be x2x2. x2x2x2x2x_x8 x2x2x2x2x4x4 x2x2x4x2x2x4 x4x2x2x2x2x4 x2x2x2x2x2x2x4 x_x8x4x2x2 x4x4x4x2x2 x_x8x2x2x2x2 x2x2x4x4x2x2 HPM-SRSDE User’s Manual 87...
Page 88
Gen4: Gen4 controller only Gen5: Gen5 with or without mix Gen5 Port 3 Subsystem Mode Protocol Auto Negotiation[Default] mode Auto: Auto select Force CXL: There is no training discovery, the attached device must also supports this mode. 88 HPM-SRSDE User’s Manual...
Option Description Auto[Default] In auto mode the BIOS will remove the EXP port if PCI-E Port there is no device or errors on that device and the device is not HP capable. Enable/Disable is used to HPM-SRSDE User’s Manual 89...
Page 90
Compliance Mode port. MCTP Enable/Disable MCTP. Yes[Default] Equalization Bypass To Disable Equalization Bypass To Highest Rate Support Highest Rate Enable[Default] Enable/Disable. Disable[Default] Enable/Disable CXL Drift Buffer if there is a CXL Drift Buffer Enable common reference clock. 90 HPM-SRSDE User’s Manual...
Eneble/Disable Intel Virtualization Technology for Directed I/O (VT-d) by reporting the I/O device Enable[Default] Intel VT for Directed I/O Disable assignment to VMM through DMAR ACPI Tables. To disable VT-d, X2APIC must also be disabled. 3.6.4.3.4 Intel VMD technology HPM-SRSDE User’s Manual 91...
Programming. 3.6.4.4.2 CPU C State Control Item Option Description Disable Allows Monitor and MWAIT instructions, Enable Monitor MWAIT Enable Auto maps to Enable. Auto[Default] CPU C1 auto demotion Disable Allows CPU to automatically demote to C1. 94 HPM-SRSDE User’s Manual...
Will be enforced to Enhanced Halt State (C1E) Enable[Default] enable when Optimized Power Mode is enabled. ACPI C2[Default] Report CC3/CC6 to OS ACPI C2 or ACPI OS ACPI Cx ACPI C3 3.6.5 Server Mgmt HPM-SRSDE User’s Manual 95...
Page 96
Configure how the system should respond if AC Power Last Power State Power Control Policy is lost, Reset not required as selected Power policy will Power Restore Unspecified[Default] be set in BMC when policy is saved. 96 HPM-SRSDE User’s Manual...
Choose options for reactions to a full SEL. Delete Oldest Record Disabled Both Disable the logging of EFI Status Codes or log Log EFI Status Codes Error code[Default] only error code or only progress code or both. Progress code HPM-SRSDE User’s Manual 97...
HPM-SRSDE User’s Manual 3.6.5.4.2 BMC Delete User Details Item Description User Name Enter BMC User Name. 3.6.5.4.3 BMC Change User Settings Item Description User Name Enter BMC User Name. 100 HPM-SRSDE User’s Manual...
65535 will disable the timeout completely. On[Default] Bootup NumLock State Select the keyboard NumLock state Disabled[Default] Quiet Boot Enables or disables Quiet Boot option Enabled Hard Disk[Default] Boot Option #1 NVME Set the system boot order. CD/DVD 102 HPM-SRSDE User’s Manual...
Page 103
Optimized Boot will disable Csm support and Disabled[Default] disable connecting Network devices to decrease Optimized Boot Enabled boot time. While disabling Optimized Boot, make sure to restore Csm Support option to previous value before enabling Optimized Boot. HPM-SRSDE User’s Manual 103...
Use the save changes and reset option to save the changes made to the BIOS options and to exit the BIOS configuration setup program. 3.6.8.2 Discard Changes and Exit Use the Discard changes and Exit option to exit the system without saving the changes made to the BIOS configuration setup program. 104 HPM-SRSDE User’s Manual...
This option saves a copy of the current BIOS settings as the User Defaults. This option is useful for preserving custom BIOS setup configurations. 3.6.8.9 Restore User Defaults This option restores all BIOS settings to the user defaults. This option is useful for restoring previously preserved custom BIOS setup configurations. HPM-SRSDE User’s Manual 105...
HPM-SRSDE User’s Manual 4. Drivers Installation Note: Installation procedures and screen shots in this section are for your reference and may not be exactly the same as shown on your screen. 106 HPM-SRSDE User’s Manual...
Windows 10 operation system. If the warning message appears while the installation process, click Continue to go on. Step 3. Click Install. Step1. Click Next. Step 4. Setup completed. Step 2. Click Accept. HPM-SRSDE User’s Manual 107...
Note: The installation procedures and screen shots in this section are based on Windows 10 operation system. Step 3. Click Next. Step 1. Click Next to continue installation. Step 4. Click Next. Step 2. Click Next. Step 5. Click Install. 108 HPM-SRSDE User’s Manual...
All drivers can be found on the Website. Note: The installation procedures and screen shots in this section are based on Windows 10 operation system. Step 1. Click Yes to continue installation. Step 2. Setup completed. 110 HPM-SRSDE User’s Manual...
All drivers can be found on the Website. Note: The installation procedures and screen shots in this section are based on Windows 10 operation system. Step 1. Click OK to continue installation. Step 2. Setup completed. HPM-SRSDE User’s Manual 111...
Note: The installation procedures and screen shots in this section are based on Windows 10 operation system. Step 3. Click Accept. Step 1. Click Install to continue installation. Step 4. Click Next. Step 2. Click Next. Step 5. Click Install. HPM-SRSDE User’s Manual 113...
Need help?
Do you have a question about the HPM-SRSDE and is the answer not in the manual?
Questions and answers