Page 54
COMPRESSOR MOTOR Com p ressor Motor S p ecifications RAC-SH09WHLAE MODEL RAC-SH12WHLAE COMPRESSOR MODEL ASD102SKQA6JK6 PHASE SINGLE RATED VOLTAGE AC 220 - 240V RATED FREQUENCY 60 Hz POLE NUMBER CONNECTION YELLOW ° 2M = 2.167 ° (6 8 RESISTANCE VALUE ( 1 6 7 °...
Page 55
MODEL RAS-SH09RHLAE MODEL RAC-SH09WHLAE RAS-SH12RHLAE RAC-SH12WHLAE RAS-SH07QHLAE (2A) F3(2A) (BLK) (25A) F6(3.15A) F5(3.15A)
Page 57
CIRCUIT DIAGRAM MODEL RAS-SH07QHLAE RAS-SH09RHLAE RAS-SH12RHLAE BOARD TYPE DRAWING FORM #INSERT-AS DD0010111A A,R,C,S MAIN PWB #BOARD-AS DD0010318A RESISTOR RESISTOR XH-7P(Top)WHT CAPACITOR DIODE 2、3pin(none) VALUE ASSY. VALUE ASSY SYMBOL TOLERANCE WATT FORM GROUP REMARK SYMBOL TOLERANCE WATT FORM GROUP REMARK (Ω) (Ω)
Page 58
MAIN-PCBA HIC-PCBA HEATER-PCBA Capacitor Resistor Capacitor Transistor Resistor Resistor Rate Rate Rate Rate Rate Symbol Symbol Symbol Symbol Resistance Tolerance Electric power Symbol Capacity Voltage Type Symbol Model type Resistance Tolerance Electric power Capacity Voltage Type Resistance Tolerance Electric power R001 1.43M C001...
Page 87
Q904, Q905, Q906 Q901, Q902, Q903 LD301 5P-TERMINAL DB602 Q602 HIC PWB Q601 Smoothing Capacitor (C021, C022) Because high voltage flows, be careful about electric shock. Also,be careful about short-circuit accidents by improper connection of measuring instruments, which can damage the board. 3.
Page 93
8. Base Heater Circuit Relay PCB FU5(3A Fuse) 3 Base Heater AC230V 1 Temp. Fuse protector Heater relay VH3P Fig 8-1 When the outdoor temperature is lower than a certain temperature, the base heater begins to work and the defrosting ability is enhanced. When the outdoor temperature is higher than a certain temperature (7±3°C), the protector will work arel.
Page 96
(4) Remove the two lock screws from the fan motor holder and one screw from the evaporator support plate. (5) Pull up the evaporator by holding it at the lower side. Insert a screwdriver through the space between the evaporator and fan motor holder and loosen the fan lock screws to remove the air flow fan and fan motor.
Procedure for Disassembly and Reassembly OUTDOOR UNIT MODEL RAC-SH09WHLAE,RAC-SH12WHLAE 2. Dismantle procedure of MAIN PWB. (1) Remove terminal cover. 1. Electrical Parts (1) Remove the top cover fixing screws Terminal Cover and lift the cover to remove it. (2) Remove the handle cover fixing screws and push it down to take it out.
Page 99
(4) Remove each connector and earth cable from the lead wire.Then,remove the electrical box. Fig.13 3. The PWB. (1) Remove the electrical cover. detents Fig.14 (2) Remove the PWB from the support. detents detents Fig.15...
Page 108
While pressing and holding (ON/OFF) button and button, press [RESET] button on the same. Release [RESET] button only and make sure that all marks on the remote controller display are indicated then release the (ON/OFF) button and button. Remote controller now enters "Shift Value Change Mode". Press the (MODE) selector button so that the display indicates (FAN) mode.
Page 109
SETTING THE PREVENTION OF MUTUAL INTERFERENCE FOR REMOTE CONTROLLER a.) Other indoor circuit breakers should be disconnected. b.) Remove the back cover of the remote control. c.) Cut the jumper as shown below. d.) Press “Reset” button after installing the battery. e.) Corresponding to the room electrical box dial code 6 to dial on.
Page 110
HOW TO CHANGE THE FAN SPEED IN COOLING MODE DURING THERMO OFF The fan speed in Cooling Mode during thermo off can be changed by the remote controller. (This procedure shall be implemented strictly by service personnel only.) It is possible to return it to the default setting. PROCEDURE Press [POWERFUL] button and...
Page 111
HOW TO CHANGE THE INTERMITTENT FAN HEATING SETTING The intermittent fan control during thermo o in Heating mode can be changed by the remote controller. (The procedure should be done only by service personnel.) It is possible to select from 3 patterns. PROCEDURE Press (POWERFUL) button,...
Page 112
DISPLAY OPERATION MODE SETTING For operating indoor unit independently (without outdoor unit connection), remote controller must be set according to below procedures before send the signal to the indoor unit. New communication format between indoor and outdoor is required to communicate with outdoor unit.
Page 131
How to run the product with the outdoor unit test switch If the indoor electrical parts is out of order and if you wish to run the outdoor unit. 1. Turn OFF main power supply. 2. Unplug the CN18 and CN3 connector. 3.
Page 134
MODEL : RAS-SH07QHLAE RAS-SH09RHLAE RAS-SH12RHLAE...
Page 135
MODEL RAS-SH07QHLAE, RAS-SH09RHLAE, RAS-SH12RHLAE PART NO. Q'TY / UNIT PARTS NAME PMRAS-S18CPA AUTO SWEEP MOTOR PMRAK-50PPD TANGENTIAL FLOW FAN PMRAK-50PPD FILTER PMRAK-50PPD TERMINAL BOARD (3P) PMRAS-25YH4 SPRING PMRAS-25YH4 P-BEARING ASSY PMS-SH09RHLAE PWB RECEIVER PMS-SH09RHLAE FAN MOTOR PMS-SH09RHLAE FRONT COVER ASSY...
Page 137
MODEL RAC-SH09WHLAE, RAC-SH12WHLAE PART NO. Q'TY / UNIT PARTS NAME C ABINET S 04 PMRAM-33NP2E FAN MOTOR PMRA C -XH18 C KT S 02 C OMPRE SS OR S 01 PMC-EH09WHLAB C ONDEN S ER PMC-SH09WHLAE S 02 D- G RILL PMRA C -VX10 C J S 04 OVERLOAD RELAY C OVER...