MUSASHI ENGINEERING ShotMaster 300SX Instruction Manual page 252

Table of Contents

Advertisement

2-1. Dispensers that can be Connected to this Robot and Corresponding
Input Signals
Dispenser
Dispenser Models
Connection Cable
MS-1/1D-CTR
SM-CB-1604P
ML-5000XⅡ-CTR
ME-5000P-CTR-T1/T2/T3/T4
*1
S-SIGMA-CM3-V2/V5
*1
S-SIGMA-X3-V2/V5
*1
ME-5000VT(-LP)-CTR
*1
ME-5000SP-CTR
*1
ML-808GX-CTR
ML-6000X-CTR-N-VHR/GP
ML-6000XP-CTR-V2/V5-N-VHR/GP
SM-CB-DSUB25P
ML-8000X-CTR-V2/V7-N/P
*1
SMP2-C
*1
SMP3-C
*1
MPP-1-C-2(-CE)
*1
MPP-3-C-1
*1
MSD3-CTR
*1
VSD-1-CTR1
*1
MJET-3-CTR
*1
MJET-4-CTR
SMDS-CB-JET3
*1
MJET-S-CTR
*1
MJET-S-CTR-RM(-2)
*1*2
S-SIGMA-CM3-V2/V5
*1*3
S-SIGMA-X3-V2/V5
*1*2*5
ME-5000VT(-LP)-CTR
*1*2*5
ME-5000SP-CTR
*1*2
ML-808GX-CTR
ML-6000X-CTR-N-VHR/GP
ML-6000XP-CTR-V2/V5-N-VHR/GP
CB-DSUB25-□M
ML-8000X-CTR-V2/V7-N/P
*1*2
SMP2-C
*1*2
SMP3-C
*1*3*5
MJET-3-CTR
*1*3
MJET-S-CTR
*3
MJET-S-CTR-RM(-2)
*1*2
MSD3-CTR
MSD-3-CTR
CB-DSUB15-
MJET-S-CTR
1204P-□M
MJET-S-CTR-RM(-2)
VSD-1-CTR1
Remarks
Please see the corresponding dispenser instruction manual for details regarding input/output signals.
*1: Dispensing operation is possible using SM-CB-1604P but other signals are restricted.
*2: Dispensing operation is possible using SM-CB-DSUB25P but other signals are restricted.
*3: Dispensing operation is possible using SMDS-CB-JET3 but other signals are restricted.
*4: The dispenser I/O terminal and the desktop robot I/O2 connector are connected together with the same pin
number.
The dispenser dispensing signal is "OUT23". Note that "OUT13" can be output by using the desktop robot
operation [SHOT] button if "13" is specified for dispenser button setting of USER PRM2 (p. 129).
For more detail about the input and output signal number, please see P.218.
*5: The "Dispensing Conditions Channel Switch" (DIS. COND.) command (p. 113) cannot be used.
*6: In the "ML-8000X" series, the pin assignment of the I / O connector can be changed on the controller.
The initial values are listed in the table.
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
Connecting
Connector
OUT 27
MT-410 Series
MK-201-C
I/O 1
Dispense
DIS
DIS
DIS
DIS
I/O 1
*6
DIS
DIS
DIS
DIS
DIS
I/O 1
DIS
*2
*2
I/O 2
*2*6
*1*2
MPP-1-C-2(-CE)
*1*2
MPP-3-C-1
*1*3
MJET-4-CTR
*1*2
VSD-1-CTR1
MJET-4-CTR
Synchro-
Speed
SM-ΩX/SX Desktop Robot - Part 5 Specifications
Input/Output Signals
OUT 14
OUT 15
OUT 16
OUT 18
-
-
-
-
TMS
TMD
-
-
TMS
TMD
-
-
PRESET
STEP
-
-
TMS
TMD
-
-
PRESET
STEP
-
-
TMS
TMD
-
-
FILL
RESET
-
-
TMS
TMD
-
-
TMS
TMD
-
-
MAIN
MODE
-
SUB
CHS
All input/output signals of the dispenser I/O terminal (Dsub-25 pin) can be used.
Dedicated connection terminal for the Synchro-Speed function
251
IN 10
IN 11
IN 12
IN 14
End
-
-
-
dispense
-
DVO
RSM
-
-
V-DOWN
-
-
VOP
T-DOWN
-
Dis_Now
PCS
-
-
ALARM
-
-
AI END
ALARM
-
DSO
PCS
-
-
-
RSM
-
-
DSO
LIMIT
-
-
DSO
-
-
-
DSO
-
-
DOWN
LINE
MAN
-
ALARM
ERROR
T.READY
*4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ShotMaster 300SX and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF