Wiring Example: Ws700 Series Wind Sensor - B&G HERCULES Basic Operation Manual

Hide thumbs Also See for HERCULES:
Table of Contents

Advertisement

Wiring example: WS700 series wind sensor

Note: The wind sensor's screen wire must be connected to the screen pin on the power connector, or a
¼
screen pin on one of the analog connectors, on the circuit board.
Pin function
Rx_A (+)
Rx_B (-)
Tx_A (+)
Tx_B (-)
12 V out
0 V
Baud rate: 38,400
Data bits: 8
Parity: None
Stop bits: 1
Wire from sensor (typical color)
Signal out, + (white)
Signal out, - (blue)
Not connected
Not connected
12 V DC + (red)
DC - (black)