ATS CONTROL MODULE
The ATS control module contains the TEST/AUTO/OFF switch and
LEDs that indicate type of power delivery.
UTILITY
UTILITÉ
UTILIDAD
TEST / ESSAI / PRUEBA
AUTO / AUTO / AUTOMÁTICO
OFF / ARRÊT / APAGADO
TEST/AUTO/OFF Switch
– TEST – This position allows verification that the generator
power delivery circuit is functional. With the switch in
the TEST position, the engine will start and the ATS will
transfer. The GENSET LED, ATS LED (middle LED) and
LOAD LED should be lit, indicating the generator power
delivery circuit is functional.
– AUTO – This position allows automatic delivery of power
from the generator if there is a utility outage. With the
switch in the AUTO position and the engine not running,
the UTILITY LED, ATS LED (middle LED) and LOAD LED
should be lit, indicating the household is using utility
provided power.
– OFF – This position will not allow any power to be
delivered to the ATS when the engine is running.
LOAD
GENSET
CHARGER
GENSET
CARGA
GENSET
fCC Statement
* Applicable in USA only.
1. This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
1a. This device may not cause harmful interference.
1b. This device must accept any interference received,
including interference that may cause undesired
operation.
2. Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications.
CAN ICES-002/NMB-002
* Applicable in Canada only.
This device complies with Industry Canada license - exempt RSS
standard(s).
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including
interference that may cause undesired operation of the
device.