SEELEY INTERNATIONAL BRAEMAR ECOSTAR TH3 Series Installation Manual

Gas ducted heaters
Hide thumbs Also See for BRAEMAR ECOSTAR TH3 Series:

Advertisement

BRAEMAR ECOSTAR GAS DUCTED HEATERS
INSTALLATION MANUAL
MODELS COVERED BY THIS MANUAL:
TH3 series - 3.7 stars
z
TH4 series - 4.7 stars
z
TH5 series - 5.6 stars
z
Heaters
supplied in this
configuration
ex-factory.
TH3/TH4/TH5 SERIES - Configured for
EXTERNAL, INTERNAL or UNDER
FLOOR INSTALLATION
(with correct flue system)
THIS HEATER IS TO BE INSTALLED BY AN AUTHORISED PERSON ONLY
DO NOT
Operate this appliance before reading the instruction booklet.
DO NOT
Place articles on or against this appliance.
Use or store flammable materials near this appliance.
DO NOT
DO NOT
Operate this appliance with panels, covers or guards removed.
This Braemar gas ducted heater must be installed in accordance with these instructions, local
gas fitting regulations, municipal building codes, electrical wiring regulations, Australian
Standard AS/NZS 5601 Gas Installations and any other relevant statutory requirements.
This heater must not be installed downstream from an evaporative cooler, air washer or
indoor unit of a refrigerated system. This heater is not suitable for installation in a marine
environment.
For external installations, ensure that the heater is located to maintain the minimum flue
clearances as specified below and in AS/NZS 5601. Measurement is taken from the edges of
the flue terminal.
GAS TYPE:
GAS CONSUMPTION:
UNPACKING THE HEATER
Remove the plastic wrap and cardboard transport cover. Check that the heater model and
gas type is as required - model details are provided on the specification label on the end
panel of the heater, gas type is given on the label next to the gas inlet. Report any transit
damage within 7 days - Do not install the heater if it is damaged.
Refer label alongside gas inlet.
Refer data label on underside of appliance lid.
SEPTEMBER 2011
Manual Part No: 623467r
TH3-TH4-TH5
Heaters can be
converted to this
configuration
on-site.
TH3/TH4/TH5 SERIES - Configured for
INTERNAL or UNDER FLOOR
INSTALLATION
(with correct flue system)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRAEMAR ECOSTAR TH3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SEELEY INTERNATIONAL BRAEMAR ECOSTAR TH3 Series

  • Page 1 BRAEMAR ECOSTAR GAS DUCTED HEATERS INSTALLATION MANUAL TH3-TH4-TH5 MODELS COVERED BY THIS MANUAL: TH3 series - 3.7 stars TH4 series - 4.7 stars TH5 series - 5.6 stars Heaters Heaters can be supplied in this converted to this configuration configuration ex-factory.
  • Page 2: Heater Configuration

    HEATER CONFIGURATION SWAPPING INLET & OUTLET PANELS The heater side panels can be moved to suit a range of installations. To do this: z Remove heater top panel. z Remove the screws securing the side/end panels that are to be changed. z Remove the side panels.
  • Page 3 SPLITTING AND RE-CONNECTING THE "TH" HEATER All TH series heaters can be split in two (remove fan box) to assist in lifting heaters into ceilings and moving the heater into position: SPLITTING THE TH HEATER: Remove the heater top panel. Disconnect the wiring loom at the plug near the top of the centre panels.
  • Page 4 The owner should be advised to clean the filter every 2 weeks and replace annually. an additional SCC & loom is required for each additional zone - SCC/loom kit P/No 076010. z Zone dampers and suitable wiring (not supplied by Seeley International).
  • Page 5 ADD-ON REFRIGERATED COOLING TH Extra Air heaters are designed for use with an add-on refrigerated cooling system - these models include an “X” in their model numbers, eg, TH3X20, TH4X30 and TH5X32. The following points must be taken into account to ensure correct operation of both the refrigerated cooler and the heater.
  • Page 6 Seeley International Pty Ltd has a policy of continuous improvement and may therefore make changes to these specifications without notice. Whilst every care has been taken to assure the accuracy of the data in this manual, Seeley International does not assume any liability for errors and/or omissions.
  • Page 7: Gas Connection

    Electrical wiring & fittings must be installed by a licensed Electrician. Active Neutral Seeley International recommends that all Braemar gas ducted heaters are wired with a dedicated circuit from the distribution board with a separate circuit breaker. Wiring must be installed in accordance with the relevant electrical standards &...
  • Page 8: Thermostat Installation

    THERMOSTAT INSTALLATION THERMOSTAT LOCATION The wall control should be located central to the main living area approximately 1.5 m above floor level. The main living area should be confirmed with the occupants. Wall control placement is critical to ensure correct functioning of the heating system. The following points must be taken into account: Avoid direct sunlight.
  • Page 9 HEATER DIMENSIONS Dimension (mm) Heater Model TH3 and TH4 models TH315, TH415 TH320, TH420 TH325, TH425 TH330, TH430 TH435 TH3X20, TH4X20 TH3X25, TH4X25 TH3X30, TH4X30 TH5 models TH516 1150 1065 1000 TH523 1150 1065 1000 TH532 1165 1055 TH5X23 1150 1115 1000 TH5X32...
  • Page 10: Installation Checklist

    INSTALLATION CHECKLIST PLEASE TICK THE BOXES TO CONFIRM THAT ALL RELEVANT TASKS ARE COMPLETE AND RETURN THIS FORM TO THE DEALER Customer name: _____________________________________________________________ Customer address: ___________________________________________________________ Model number: ____________________ Serial number: __________________ ‡ Outside ‡ In ceiling ‡Under floor Heater installed: ‡...
  • Page 11 EXTERNAL INSTALLATION HEATER BASE FLUE CONNECTION - TH3 & TH4 Construct the heater base and prepare wall opening to the dimensions shown in the table Push vent cowl onto heater flue outlet spigot. below. Align hole in flue cowl spigot with hole in heater flue outlet, and secure in place with screws ENSURE THAT THE BASE IS LEVEL IN BOTH DIRECTIONS.
  • Page 12 CEILING INSTALLATION HEATER PLATFORM AND CLEARANCES FLUE CONNECTION - TH3 & TH4 This heater must be flued using AGA approved 100 mm metal flue pipe. The heater must be mounted on a platform to enable access for servicing and maintenance. External joins - socket must face downwards.
  • Page 13 UNDER-FLOOR INSTALLATION There is to be a minimum clearance of 200mm between the lowest part of the floor structure and any part of the heater. The heater is to be located within 2m of the access opening, or there is to be a minimum clearance of 1.2m between the lowest part of the floor structure.
  • Page 14 5 STAR FLUE SYSTEM & CONDENSATE DRAIN FLUE SYSTEM: - Braemar TH5 heaters must be flued using 100mm DWV plastic pipe and components complying with AS1260. - The flue terminal on the side of the heater is designed to accept either the male end of a 100mm DWV M-F elbow, or 100mm DWV pipe.
  • Page 15 COMMISSIONING - INSTALLER OR COMMISSIONING AGENT INSTALLATION CHECKS SET THE MAXIMUM FAN SPEED Check for gas leaks - rectify any leaks found. 3 STAR HEATERS 4 & 5 STAR HEATERS Check that the flue system is connected, sealed and installed with appropriate clearances. Check that thermostat is wired correctly and installed in a suitable location.
  • Page 16 TROUBLE SHOOTING & DIAGNOSTICS IF THE HEATER FAILS TO START CHECK THE FOLLOWING: DIAGNOSTIC CODES (SCC thermostat required - refer service manual for full instructions) POTENTIAL PROBLEM CHECK/REMEDY 3 STAR HEATERS No power. Is green LED on BSC circuit board on ? Code Shut down SCC display...
  • Page 17: Kit Description

    240 Vac zone kit 077208 Spectrolink comfort control thermostat (SCC) 076010 Note: - Zone dampers are not supplied by Seeley International and are not included in the above zone kits. MISCELLANEOUS KITS KIT DESCRIPTION KIT PART No Spectrolink comfort control (SCC)
  • Page 18 NOTES...

Table of Contents