LED2: Net Status
LED Status
OFF
ON
Flashing (green) no connection
ON
Flashing (red)
LED3: PORT1 - Link / Data Activity
LED4: PORT2 - Link / Data Activity
LED Status
OFF
ON = Link
Flashing =
Data Activity
LED color
green
yellow
For appropriate measures in case of error see chapter "Causes of faults and remedies"
on page 195.
6.3 MAC-Address
Already by TR-Electronic each EtherNet/IP™ device a worldwide explicit device
identification is assigned und serves for the identification of the Ethernet node. This 6
byte long device identification is the MAC-Address and is not changeable.
The MAC-Address is divided in:
●
3 Byte Manufacturer-ID and
●
3 Byte Device-ID, current number
Normally the MAC-Address is printed on the connection hood of the device.
E.g.: "00-03-12-04-00-60"
Printed in the Federal Republic of Germany
06/29/2023
Description
Not powered, no IP address
(green) connection established
(red)
The device has detected that its IP address is already in use
One or more of the connections in which this device is the target
has timed out. This state is left only if all timed out connections
are re-established or if the device is reset.
Description
- Voltage supply absent or too low
- No Ethernet connection
- Hardware error, measuring system defective
Ethernet connection established
Data transfer TxD/RxD
Description
Normal operation
Transmission error detected on port. The data transmission
remaining unchanged. After 60 sec. the status changes to
"green" again.
TR-ECE-BA-DGB-0135 v07
TR-Electronic GmbH 2017, All Rights Reserved
Page 121 of 200
Need help?
Do you have a question about the CEV582M-32768/4096 EIP 36ZB10FL and is the answer not in the manual?
Questions and answers