klover BELVEDERE 20 Installation - Use - Maintenance

Wood boiler stove

Advertisement

Quick Links

BELVEDERE 20
ENGLISH
wood boiler
stove
INSTALLATION, USE, MAINTENANCE
AND TIPS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BELVEDERE 20 and is the answer not in the manual?

Questions and answers

Summary of Contents for klover BELVEDERE 20

  • Page 1 BELVEDERE 20 ENGLISH wood boiler stove INSTALLATION, USE, MAINTENANCE AND TIPS...
  • Page 3 DoP/KLOVER-028 Identification number : BV20 Model and/or lot no. and/or serial no. (Art.11-4) : BELVEDERE 20 Intended use of the product according to the relevant Home heating appliance fed with wood logs harmonised technical specification which can also produce domestic hot water KLOVER s.r.l.
  • Page 4: Table Of Contents

    CONTENTS CONTENTS .......................................... 1 INTRODUCTION ......................................... 3 .................................. 3 MPORTANT SAFETY INSTRUCTIONS THE APPLIANCE AND WOOD ..................................4 ..................................4 OMPONENTS OF THE APPLIANCE ...................................... 8 VERALL DIMENSIONS ....................................9 ONNECTIONS DATA SHEET ..................................10 ECHNICAL PECIFICATIONS ......................................10 YPES OF WOOD REQUIREMENTS OF THE PLACE OF INSTALLATION ..........................
  • Page 5 EN - Rev. 2.3 Dear client, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Read the warranty guarantee carefully, which is found on the last page of this User guide; fill out the attached warranty card in full and return it within 10 days from the date of purchase.
  • Page 6: Introduction

    - This user guide constitutes an integral part of the appliance. If the appliance is sold to another user, this manual must be passed on to the new owner. KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL.
  • Page 7: The Appliance And Wood

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 KLOVER S.R.L. SHALL NOT BE HELD LIABLE FOR THE INSTALLATION OF THE APPLIANCE. THE INSTALLER IS THE SOLE PARTY RESPONSIBLE FOR THIS OPERATION AND IS ALSO ENTRUSTED WITH CHECKING THE FLUE, EXTERNAL AIR VENT AND THE CORRECTNESS OF THE PROPOSED INSTALLATION SOLUTIONS. ALL THE SAFETY REGULATIONS SET OUT IN THE SPECIFIC LAWS IN FORCE IN THE COUNTRY OF THE STOVE'S INSTALLATION MUST BE OBSERVED.
  • Page 8 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Draught regulation handle. Upper smoker damper. Turn the handle to the vertical position to open. Cover Turn the handle to the SICURO TOP. horizontal position to close. Electronic control unit. Primary manual Combustion chamber.
  • Page 9 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Safety valve Ash collection drawer. calibrated to 2.5 bar FRONT VIEW TECHNICAL COMPARTMENT Heating system loading High-efficiency circulating Boiler unit drain cock. cock. pump for heating system. Secondary automatic combustion air damper.
  • Page 10 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 UPPER VIEW TECHNICAL COMPARTMENT Domestic hot water outlet pipe connection (on prepared models only). DCW inlet pipe connection. + System load. + Boiler unit load. Delivery pipe connection of the heating system with check valve.
  • Page 11: Overall Dimensions

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Overall dimensions...
  • Page 12: Connections Data Sheet

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Connections data sheet REAR VIEW Description of connections M = System Delivery 3/4" F R = System Return 3/4" F F = Domestic cold water inlet (on prepared models only) and boiler unit and system load 1/2"...
  • Page 13: Technical Specifications

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Technical Specifications Nominal heat input kW (Kcal/h) 28.1 (24,200) Nominal thermal output kW (Kcal/h) 22.6 (19,500) Nominal power released to heating water kW (Kcal/h) 13.1 (11,300) Nominal power delivered to room due to radiation kW (Kcal/h) 9.5 (8,200)
  • Page 14 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 is directly affected by the type of wood used, on average a well-seasoned wood has a calorific value of 3200 kcal/kg. Calorific value of wood in relation to humidity: % humidity...
  • Page 15: Requirements Of The Place Of Installation

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 REQUIREMENTS OF THE PLACE OF INSTALLATION Positioning The initial phase for best installation of the appliance is to determine its optimum location; the following elements need to be considered: - The possibility of creating an external air vent;...
  • Page 16: The Flue Pipe And Connection To The Same

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 The flue pipe and connection to the same The flue pipe is an essential element for the efficient operation of the appliance. The boiler stove smoke outlet is 150mm in diameter. The flue must have a minimum cross section of 180 mm with a minimum height of 4 metres. Each product must be equipped with its own flue, without other adjoining elements (boilers, chimneys, stoves etc.).
  • Page 17: Electrical Connection

    Connection to the mains power supply should only be carried out after the wires have been connected to the terminal board. KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
  • Page 18 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Two cables exit the control unit, one of which has no plug. The cable with the plug should be connected to a mains socket with the specifications detailed above. The insulated cable with 4 wires should be connected to the three-way motorised valve installed in the domestic water system (see section “Control of a possible three-way motorised valve for...
  • Page 19 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 - L4 LEVEL SWITCH LED The LED turns on when the tank is empty or the water level is too low. - L5 OFF LED This LED is lit when the control unit is off.
  • Page 20 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 - NO ICE function: If the temperature detected by the H2O PROBE goes below the value of the ANTIFREEZE Thermostat, this activates the timed PUMP outlet. The relative L1 LED turns on and ICE starts flashing on the display.
  • Page 21: Control Of Any Coupled Boiler

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 FAULT SIGNALLING AND ALARMS The control unit signals faults associated with the H2O PROBE via a flashing message: - Lo: indicates a value below the set scale (temperature below 0°C) Occurs when the H2O PROBE is off.
  • Page 22: Control Of A Possible Three-Way Motorised Valve For The Dhw System (On Prepared Models Only)

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 at the same time on the same system, thus maximising performance and management of the system itself. The coupled boiler may however be used for the production of domestic hot water.
  • Page 23: Example Of Electrical Connection

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Example of electrical connection - LINE: Connect terminals 1 and 2 to the electrical power supply (terminals already connected to power supply cable in the factory). - AUX: This is used to control a boiler coupled with the heating system where present. Connect terminals 4 and 5 (or 3 and 4 depending on the type of connection to the coupled boiler) to the RT (Room Thermostat) contact on the boiler.
  • Page 24: Hydraulic Connection

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 - PROBE: Connect the water temperature probe to terminals 18 and 19. This is used to detect the water temperature inside the appliance. If the probe is not connected, the control unit's display shows “Lo”; if the probe is short- circuited, the display shows “Hi”.
  • Page 25 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Now open the fire door to access and make the plumbing connections inside the combustion chamber (figure 6). Once the connections have been made, reverse the above procedure, carefully replacing all the parts previously removed,...
  • Page 26: Initial Start-Up

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 INITIAL START-UP Filling the boiler unit and the system for the first time After connecting the appliance to the water system, fill the boiler unit as follows: - Dilute the Long Life product to 2% by pouring the contents of the bottle directly into the boiler unit (See section “Maintenance of the boiler...
  • Page 27 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 - open the smoke damper on the flue port by setting the handle to the vertical position; - Open the “primary manual air combustion damper” by turning the knob left. - Open the “secondary automatic air combustion damper” by turning the knob fully anti-clockwise.
  • Page 28: Operation

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Operation To avoid possible damage and/or deformation to the appliance, it is essential not to load excessive amounts of fuel. It is also recommended to burn only good quality, dry and well-seasoned wood (cut at least 2 years).
  • Page 29: What Happens If

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 - Any perceived noise during operation may be caused by the expansion settling of the plates that make up the boiler unit. These noises are accentuated especially during ignition and switching off phases of the appliance and are not to be considered a manufacturing fault.
  • Page 30: Cleaning And Maintenance

    BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 - Insufficient emission cross section. - CONDENSATE ESCAPING THROUGH THE MASONRY. ELEMENTS TO CHECK ORIGIN Flue gas channel - Use of inadequate material; Flue - Absence of or incorrect installation of the dedicated condensate Condensate tray collector with drain connected to the disposal system.
  • Page 31 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3 Remove the five cast iron partitions inside the combustion chamber (figure 1). Next, remove the cast iron grate (figures 2 3). Remove any deposits from the walls of the combustion chamber.
  • Page 32: Cleaning The Ash Drawer

    You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
  • Page 33: Maintenance Of The Boiler Unit

    ATTENTION!!! NON-USE AND OR AN INCORRECT DOSAGE OF LONG LIFE WILL INVALIDATE THE WARRANTY ON THE BOILER UNIT. LONG LIFE gas been designed and tested on SICURO TOP products; KLOVER declines all liability arising from the use of LONG LIFE in products or applications other than those indicated.
  • Page 34: Warranty Conditions

    The warranty period starts from the date of purchase of the appliance, which must be demonstrated by a delivery document and the warranty coupon duly completed and sent in a sealed envelope to the address of KLOVER SRL. These documents must be shown to the Technical Assistance Centre, if required.
  • Page 35 BELVEDERE 20 WOOD BOILER STOVE EN - Rev. 2.3...
  • Page 36 Cod. CS.IST.BV20-EN.FP KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) VAT No. 02324280235 www.klover.it...

This manual is also suitable for:

Bv20

Table of Contents