KegLand RAPT Pill KL20596 Instruction Manual

KegLand RAPT Pill KL20596 Instruction Manual

Hydrometer & thermometer
Hide thumbs Also See for RAPT Pill KL20596:
Table of Contents

Advertisement

RAPT Pill Hydrometer Instruction Manual
RAPT PILL
Hydrometer & Thermometer
KL20596
Instruction Manual
KegLand Distribution PTY LTD
www.kegland.com.au
www.KegLand.com.au
Last Updated 6/12/2023 3:24 PM
Page 1 of 21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAPT Pill KL20596 and is the answer not in the manual?

Questions and answers

Summary of Contents for KegLand RAPT Pill KL20596

  • Page 1 RAPT Pill Hydrometer Instruction Manual RAPT PILL Hydrometer & Thermometer KL20596 Instruction Manual KegLand Distribution PTY LTD www.kegland.com.au www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 1 of 21...
  • Page 2: Table Of Contents

    (https://www.youtube.com/KegLand). You can find the link on our website www.KegLand.com.au If there is any part of these videos above that you do not understand or you cannot access please call or email www.KegLand.com.au or your nearest KegLand Distributor for more assistance. Contents ................................
  • Page 3 Validation code is not appearing on the Pill Captive Portal ............20 Error message displayed on phone or tablet when connecting to the Pill Captive Portal ....20 Warranty (Australia) & Support ......................21 www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 3 of 21...
  • Page 4: Warning

    Incorrect battery orientation can damage the circuit board. • Always leak test your RAPT Pill by submerging in water prior to sanitising and dropping in your fermenter • Only use KegLand approved cleaners such as StellarOxy StellarClean and sanitisers such StellarSan Phosphoric Acid.
  • Page 5: Led Indicators

    RAPT Pill Hydrometer Instruction Manual Only use KegLand approved 18650 rechargeable Lithium-ion batteries (KL26734). If non-approved batteries are used the device will require calibration. Once installed ensure your battery has good contact with the terminals. After installing the battery rotate it slightly within the battery holder to ensure it has good contact.
  • Page 6: Registering Your Device

    1. Select your home Wi-Fi network in the RAPT Pill captive portal, enter your home Wi-Fi network password and select Join. This will connect your Pill to your Wi-Fi network. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 6 of 21...
  • Page 7: Check For New Firmware

    To keep the Captive Portal open for up to 10 minutes while disconnected from USB-C (for example, in order to perform calibration of the Pill) you must first open the Diagnostics or the Calibration screen of the Pill Captive Portal. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 7 of 21...
  • Page 8: Wifi

    The Set Temperature Offset option allows to calibrate your RAPT Pill against a known, calibrated thermometer. Note: During calibration the displayed temperature will generally be higher than actual, as the battery will be in use and thus affecting the board temperature. For temperature www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 8 of 21...
  • Page 9: Diagnostics

    Send diagnostics log. This will manually send a diagnostics log. This is not required unless requested by KegLand. Reboot device: This will reboot the Pill. This can be helpful in the event of network or wifi issues.
  • Page 10: Assembly Instructions

    Once the circuit board has been inserted into the yellow housing, screw the two housings together hand-tight until both o-rings are hidden to ensure formation of a hermetic seal www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 10 of 21...
  • Page 11: Operation Instructions

    Wi-Fi settings and select the “RAPT Pill XXXX” Wi-Fi network again to open the Pill Captive Portal. 3. Once the RAPT Pill Access Portal is open on your phone or tablet, navigate to the Calibration tab. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 11 of 21...
  • Page 12: 1: Standard Calibration

    1.000. 2. Prepare another vessel capable of holding the Pill in suspension with a solution of known gravity in the range representative of the upper limit of your starting gravities. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 12 of 21...
  • Page 13: 3: Custom Calibration

    (such as not passing through the data point at 1.000 correctly or not following a polynomial shape) reduce the number of data points (ensuring that there are still more data points than the degree of the polynomial) until the curve matches. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 13 of 21...
  • Page 14 This is a sample only – DO NOT USE THIS EQUATION AS IT WILL NOT BE ACCURATE Paste this equation into the field in your Custom Calibration to complete the calibration. Congratulations! Your Pill is calibrated and ready to go. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 14 of 21...
  • Page 15: Updating Firmware

    Once Bluetooth has been enabled in the Pill Captive Portal, the Pill must be Bonded with a RAPT Bluetooth device such as a RAPT Fermentation Chamber, a RAPT Temperature Controller or a RAPT Gen 4 BrewZilla. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 15 of 21...
  • Page 16: Using Rapt Pill With Kl31936 Complete Wireless Charging Kit

    USB-C port on the Pill board. Wait for at least 30 seconds, then plug the wireless charging kit back in and replace the Pill on the charging station www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 16 of 21...
  • Page 17: Troubleshooting Registration And Telemetry Issues

    To check the signal strength, log in to the RAPT Portal and click on the information symbol below your RAPT Pill on the dashboard. Signal strength is represented on a scale of 0 to -100dbm www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 17 of 21...
  • Page 18: Re-Register Your Rapt Pill

    General Troubleshooting Red (battery) light flashes very rapidly when plugged in to USB-C Please install the battery or check that it is making good contact with the terminals. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 18 of 21...
  • Page 19: Lights Turn Off Immediately When Disconnected From Usb-C

    USB-C port instead. Wait for at least 30 seconds then reinstall the battery (ensure correct polarity) and plug the Pill back into USB-C. www.KegLand.com.au Last Updated 6/12/2023 3:24 PM...
  • Page 20: The Green Light Is Flashing But Cannot Access The Captive Portal

    Ensure that you have connected to the Pill’s wifi network on your phone or tablet (in the form KegLand Pill XXX) If the Pill Network does not show up in your list of WiFi networks it may be necessary to ‘reboot’ the Pill.
  • Page 21: Warranty (Australia) & Support

    If you purchased your unit from an international distributor, you will be required to go through their warranty claims process. For a full terms and condition please visit our website here -> Terms & Conditions www.KegLand.com.au Last Updated 6/12/2023 3:24 PM Page 21 of 21...