Advertisement
EQUIPMENT DAMAGE HAZARD.
To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
System | Voltage (50/60Hz) | Running Current |
Heat (1st stage) (Powerpile) | 20-30 Vac 750 mV DC | 0.02-1.0 A 100 mA DC |
Auxiliary heat* | 20-30 Vac | 0.02-1.0 A |
Cooling | 20-30 Vac | 0.02-1.0 A |
* TH1210DH only
* Model TH1110E1000 has a larger display than shown in image.
Up/Down buttons
Press to adjust temperature.
System switch
Fan Switch
On: Fan runs continuously.
Auto: Fan runs only when heating or cooling system is on.
Temperature
The ambient (measured) temperature is normally displayed. To view the setpoint temperature, press the Up or Down button once. The setpoint temperature will appear for five seconds.
Setpoint indicator
Appears when the setpoint temperature is displayed
Note: On model TH1110E1000, "Set" appears to the right of the temperature.
Low battery warning
Note: Model TH1110E1000 does not show Lo Batt. It shows a battery with only 1 bar of charge in the lower right corner of the display.
System status
Cool on: Cooling system is on.
Heat on: Heating system is on.
Aux On: Auxiliary heat is on. (Only for heat pumps with this capability [select models only].)
When "Heat On" or "Cool On" is flashing, compressor protection is engaged.
* Model TH1110E1000 has a larger display than shown in image.
The SYSTEM switch can be set to control your heating or cooling system, depending on the season.
EQUIPMENT DAMAGE HAZARD.
To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
* TH1110E1000 model has a larger display than shown in image.
Set the FAN switch to Auto or On.
In "Auto" mode (the most commonly used setting), the fan runs only when the heating or cooling system is on.
If set to "On," the fan runs continuously.
Note: Make sure the thermostat is set to the system you want to control (heat or cool).
* TH1110E1000 model has a larger display than shown in image.
This feature helps prevent damage to the compressor in your air conditioning or heat pump system.
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait 5 minutes before restarting.
During the wait time, the display will flash the message Cool On. When the safe wait time has elapsed, the message stops flashing and the compressor turns on.
Install two fresh AAA batteries when either Lo Batt or battery icon appears on the screen. The low battery indicator appears for 60 days before the batteries are depleted.
Replace batteries once a year, or when you will be away for more than a month.
The settings are stored in nonvolatile (permanent) memory and are thus preserved when the thermostat is without batteries.
Set the System switch to Off before removing the batteries. Otherwise, the heating/cooling system could remain activated even when batteries are removed.
For assistance with this product, please visit Honeywellhome.com/support
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.
Resideo Technologies Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
www.resideo.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Honeywell PRO 1000 Series - Non-Programmable Thermostat Manual
Advertisement
Need help?
Do you have a question about the PRO 1000 Series and is the answer not in the manual?
Questions and answers