Fujitsu AJ 126LELDH Series Design & Technical Manual page 802

Hide thumbs Also See for AJ 126LELDH Series:
Table of Contents

Advertisement

¢ Addresses and setting ranges for controllers, convertors or
other devices
Unit
Touch panel
controller
Network converter
Group remote
controller
Wired, simple
remote controller
(3-wire type)
Signal amplifier
Modbus converter
Network converter
for LonWorks
Central remote
controller
Wired remote
controller
3
(2-wire type*
)
1
*
: The sum total of the Touch panel controller, Central remote controller, Network converter for
Group remote controller, Modbus converter, and Network converter for LonWorks is a maximum
of 16.
NOTE: For Touch panel controller, Central remote controller, Network converter for Group re-
mote controller, Modbus converter, and Network converter for LonWorks connected in
same VRF network system, set an exclusive address on each device.
2
*
: The address can be set in the range of 1 to 32. However, do not set the same number as that
for the remote controller address of an indoor unit connected using the same remote-control ca-
ble.
1-2. Address setting
Setting
Setting
range
00—15
Controller
G
1
address
*
00—15
Convertor
1
address
*
H
Refrigerant
00—99
circuit address
Group remote
I
controller
00—03
address
Dual remote
J
ON/OFF Switch 2 of DIP switch 1
control
Signal amplifier
K
1—8
address
Q
Controller/
00—15
convertor
1
M
*
address
N
Remote
1—32 *
F
controller
0—15
address
Dual remote
J
ON/OFF
control
Type of switch
Setting
example 01
SW 110
(10 digit) (1 digit)
Manual address setting
Automatic address setting:
This switch is set to 1 at factory
setting.
2
Manual address setting
Automatic address setting
- (07-6) -
Setting references
"Touch panel controller"
on page
07-118"Touch
panel controller"
on
page 07-118
"Network convertor
(UTY-VTGX, UTY-
VTGXV)"
on page 07-
129 and
"Network
convertor (UTY-
VGGXZ1)"
on page 07-
SW 111
131
"Group remote
controller"
on page 07-
116
"Wired remote controller
(UTY-RNK)"
on page
07-112
"Simple remote
controller (UTY-RSK,
UTY-RHK)"
on page
07-114
"Signal amplifier"
on
page 07-133
"Automatic address
setting of signal
amplifier"
on page 07-
57
"Modbus converter for
VRF"
on page 07-
138"Modbus converter
for VRF"
on page 07-
138
"Network converter for
LonWorks"
on page 07-
143
"Central remote
controller (UTY-
DCGZ)"
on page
07-119
"Wired remote controller
(Touch panel)"
on page
07-121 and
"Wired
remote controller (UTY-
RLR)"
on page 07-
125
1. System settings