Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
To indicate that static sensitive devices are Pour indiquer que des appareils sensibles present and handling precautions should be statiques sont présents et les précautions de followed. manipulation doivent être suivies. VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A REED RELAY MODULE 40-110/115/120/125 Page (IV) Page (IV)
Blanking panels are signaux d’E/S utilisateur qui peuvent être présents. available to order from Pickering in a variety of slot Les obturateurs sont disponibles sur commande chez widths. If the product is not used in this manner for Pickering dans une variété...
Page 8
“arrêt an emergency press the red “emergency stop” d’urgence” situé sur l’avant de l’unité. button situated on the front of the unit. GENERAL PURPOSE 2A RELAY MODULE 40-131/132 Page (VIII) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page (VIII)
Supported by PXI or LXI Chassis y Supported by eBIRST ™ y 3 Year Warranty The 40-675A very high density low cost multiplexer module is Supported by eBIRST available in six switching configurations. It is suitable for signal These test tools simplify fault-finding by quickly testing the routing in high channel count ATE and data acquisition systems.
Page 11
EU directives: Low-voltage safety EN61010-1:2010, +3.3 V +5 V +12 V -12 V EMC Immunity EN61326-1:2013, 300 mA typical 0 Emissions EN55011:2009+A1:2010. PCB Layout for the 40-675A Very High Density Multiplexer Module pickeringtest.com VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 1.3...
Page 12
For example, the 99-channel 2-pole MUX with multiple channel capability would be: 40-675A-002-99/2-M Mating Connectors & Cabling For connection accessories for the 40-675A range please Product Customization refer to the 90-002D 200-pin LFH Connector Accessories Pickering modules are designed and manufactured on our...
Page 13
We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
Page 14
Very High Density Multiplexer, 40-675A Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
U8 TO U14 CONNECTOR PCI BRIDGE TERMINATING MODULE RESISTORS CONFIGURATION R4 TO R15 U5, U6 AND U7 PCI BRIDGE CONFIGURATION Figure 2.1 - Very High Density Multiplexer Module 40-675A: Functional Block Diagram VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 2.1...
VII. à la Page VII. Ensure that there is adequate ventilation. Assurez-vous que la ventilation est adéquate. VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A REED RELAY MODULE 40-110/115/120/125 Page 3.1 Page 3.1...
Page 18
9. For Pickering Interfaces modular LXI installation b. Pour un système comprenant plus d’un châssis, there is no requirement to use any particular power allumez le dernier châssis dans le système up sequence.
Si vous n’êtes pas un utilisateur de LabVIEW, vous LabVIEW Runtime Engine installer via the shortcut devez choisir la version “complète”, et une fois qu’elle on the Programs>>Pickering menu. In the absence of a été installée. Lancer le programme d’installation LabVIEW the Runtime Engine is required to support LabVIEW Runtime Engine via le raccourci dans the Pickering Test Panels application.
Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
MODULE ARCHITECTURE The 40-675A is a single bank multiplexer available in 198-channel 1-pole, 99-channel 2-pole, 49-channel 4-pole, 24-channel 8-pole, 10-channel 16-pole and 5-channel 32-pole configurations. Connections are made by operating a channel relay to make a connection between the common terminal and the corresponding channel terminal. 198, 99 and 49 channel versions include isolation relays that are automatically energised when a multiplexer path is enabled.
Once the drivers are installed the manual “Sys40Prg.pdf” and driver help files which fully describes these functions can be found in the Pickering folder(s) or the Pickering entries on your Start Menu. The card must be opened before use and closed after using the following function calls: Direct I/O Driver - Open with PIL_OpenCards or PIL_OpenSpecifiedCard and close with PIL_CloseCards or PIL_CloseSpecifiedCards respectively.
Page 24
SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 4.4...
SECTION 5 - CONNECTOR INFORMATION pickering SECTION 5 - CONNECTOR INFORMATION Figure 5.1 - Pinouts: PXI Module 40-675A-002, 198-Channel, 1-Pole Multiplexer (200-pin Female Connector Viewed From Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 5.1...
Page 26
95.1 94.1 93.1 96.1 96.2 95.2 94.2 93.2 99.1 98.1 97.1 99.2 98.2 97.2 Figure 5.2 - Pinouts: PXI Module 40-675A-002, 99-Channel, 2-Pole Multiplexer (200-pin Female Connector Viewed From Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 5.2...
Page 27
45.4 45.2 48.3 48.1 47.3 47.1 47.2 48.4 48.2 47.4 49.3 49.1 49.4 49.2 Figure 5.3 - Pinouts: PXI Module 40-675A-002, 49-Channel, 4-Pole Multiplexer (200-pin Female Connector Viewed From Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 5.3...
Page 28
23.3 23.1 23.8 23.6 23.4 23.2 24.7 24.5 24.3 24.1 24.2 24.8 24.6 24.4 Figure 5.4 - Pinouts: PXI Module 40-675A-002, 24-Channel, 8-Pole Multiplexer (200-pin Female Connector Viewed From Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 5.4...
Page 29
10.13 10.11 10.9 10.16 10.12 10.10 10.14 C.15 C.13 C.11 C.16 C.10 C.14 C.12 Figure 5.5 - Pinouts: PXI Module 40-675A-002, 10-Channel, 16-Pole Multiplexer (200-pin Female Connector Viewed From Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 5.5...
Page 30
C.19 C.17 C.24 C.22 C.20 C.18 C.31 C.29 C.27 C.25 C.26 C.32 C.30 C.28 Figure 5.6 - Pinouts: PXI Module 40-675A-002, 5-Channel, 32-Pole Multiplexer (200-pin Female Connector Viewed From Front of Module) VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 5.6...
Mises en garde au début du manuel. INSTALLATION PROBLEMS PROBLÈMES D’INSTALLATION The Plug & Play functionality of Pickering switch cards La fonctionnalité Plug & Play des cartes de generally ensures trouble-free installation. commutation Pickering assure généralement une installation sans problème.
OUTILS DE TEST DE SYSTEME DE SWITCHING SYSTEM TEST TOOLS COMMUTATION Please refer to Section 7 - Maintenance Information Référez-vous à la Section 7 - Information sur l’entretien VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A REED RELAY MODULE 40-110/115/120/125 Page 6.2 Page 6.2...
Page 33
Pour les modules PXI qui sont pris en charge dans Pickering Interfaces’ Modular LXI Chassis (such l’un des châssis modulaire LXI de Pickering Interfaces as the 60-102B and 60-103B) no module software (comme le 60-102B et 60-103B) aucune mise à jour update is required.
Utilisateurs eBIRST, les outils de test de système de commutation n’ont pas besoin d’utiliser cette fonction pour localiser les relais défectueux. VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A HIGH DENSITY REED RELAY MODULES 40-140A/141/142/143 Page 7.2 Page 7.2...
Page 41
SECTION 7 - MAINTENANCE INFORMATION pickering Spare Spare Figure 7.1 - 40-675A Very High Density Multiplexer - Component Layout VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 7.9...
Page 42
SECTION 7 - MAINTENANCE INFORMATION pickering THIS PAGE INTENTIONALLY BLANK VERY HIGH DENSITY MULTIPLEXER MODULE 40-675A Page 7.10...
Need help?
Do you have a question about the 40-675A and is the answer not in the manual?
Questions and answers