Umesh Gore
March 25, 2025

what is torque range for crimping bolt

2 comments:
Mr. Anderson
March 25, 2025

The torque values for crimping the Bollhoff RIVKLE® depend on the screw size. The recommended setting forces, which are related to torque, are:

- M4: 2.23 Nm
- M5: 4.43 Nm
- M6: 7.70 Nm
- M8: 18.60 Nm

These values ensure proper installation and prevent re-setting during the life of the RIVKLE®.

This answer is automatically generated

Umesh Gore
March 25, 2025

@Mr. Anderson, after crimping shown above values are maximum sustainable torque value ???? or it may be more , also can you tell how much cycle will apply on same bolt..

Summary of Contents for Bollhoff RIVKLE P2005

  • Page 1 RIVKLE ® Power hand tools for RIVKLE ® blind rivet nuts and studs...
  • Page 2: Table Of Contents

    RIVKLE ® – Power hands tools Contents Page RIVKLE ® - Blind rivet nuts Setting methods RIVKLE ® - Power hand tools offer overview Setting method controlling RIVKLE ® P2005 Pressure controlled installation equipment RIVKLE ® P1007 RIVKLE ® P2007 / RIVKLE ®...
  • Page 3: Rivkle ® - Blind Rivet Nuts

    RIVKLE ® – Setting methods The BÖLLHOFF recommended installation is the “pull method”. RIVKLE ® can also be installed using a press. 1 - Pressure setting methods The “pressure method” consists of: Spin on , Insert , Upset and Spin off cycles.
  • Page 4 RIVKLE ® blind rivet nut – Setting methods 2 - Installation force value The setting force is defined using combination of: RIVKLE ® installation parameters defined by our laboratory Application parameter (tensile strength after assembly and during service) 2-1 RIVKLE ®...
  • Page 5 2-2 SCREW parameters When a assembly is in use, external influences generally increase the tensile strength in the screw (F > F < < Setting Force Assembly With correct installation, RIVKLE ® exhibits the same behaviour as a standard nut. Results: 1.
  • Page 6 RIVKLE ® – Power tools and semi-automated Hydro pneumatic and RIVKLE ® P2005 RIVKLE ® P1007 RIVKLE ® P2007 RIVKLE ® P2007 PN • Stroke Setting technology • • • Force Hydro Hydro Hydro Hydro Drive pneumatic pneumatic pneumatic pneumatic min.
  • Page 7 Hydro electric tools Semi-automatic tools RIVKLE ® B2007 RIVKLE ® P3007 RIVKLE ® P3007 PN RIVKLE ® EPX009 RIVKLE ® EPK C RIVKLE ® EPK HP • • • • • • Hydro Hydro Hydro Hydro Pneumatic / Pneumatic / electric pneumatic pneumatic...
  • Page 8: Setting Method Controlling

    RIVKLE ® – How to ensure that a RIVKLE ® is correctly set? Principle RIVKLE ® is mainly used in blind conditions, so the most reliable way to ensure that a RIVKLE has been set correctly is to ensure that the setting parameters are strictly ®...
  • Page 9: Rivkle ® P2005

    RIVKLE ® – Stroke controlled installation equipment RIVKLE ® P2005 - The stroke setting power hand tool Stroke controlled hand setting tool, based on hydro-pneumatic technology. Only need to be connected to an air source. The air energy is transformed into hydraulic pressure, which drives the setting operation to the preset stroke. Advantages: Robust Fast...
  • Page 10: Pressure Controlled Installation Equipment

    RIVKLE ® – Force setting powertool RIVKLE ® P1007 / P2007 / P3007 Theory Force setting powertool, based on hydro-pneumatic technology. Only needs to be connected to an air source. The air energy is transformed in hydraulic pressure, which drives the setting operation to the preset force. The force adjustment is done on the tool using colour coding, and could be confirmed and/or monitored using force controller RIVKLE ®...
  • Page 11: Rivkle ® P1007

    RIVKLE ® P1007 - Lightweight tool for speed and accessibility Advantages: Ultra-lightweight and compact Suitable for small diameter RIVKLE ® nuts and studs Precision of the setting force 236 15 701 000 Technical characteristics / Data Maximum stroke 7.0 mm 13 kN Maximum setting force Operating air pressure...
  • Page 12: P2007 Pn

    RIVKLE ® – Force setting powertool RIVKLE ® P2007 - Flexible and versatile hydro-pneumatic tool Advantages: Versatile Adapted for serial use Compatible with various diameters of RIVKLE ® nuts and studs Ergonomic and well balanced 236 15 601 000 Technical characteristics / Data Maximum stroke 7.0 mm 21 kN...
  • Page 13: Rivkle P3007 / Rivkle P3007 Pn

    RIVKLE ® P3007 - Powerful and robust construction Advantages: Adapted for production use Adapted to large diameters of RIVKLE blind rivet ® nuts (M8 to M16) Well balanced 236 15 901 000 Technical characteristics / Data Maximum stroke 8.0 mm 40 kN Maximum setting force Operating air pressure...
  • Page 14: Rivkle Epx009 - Process Control

    RIVKLE ® – Force setting powertool - Process control RIVKLE ® EPX009 - Process control Advantages: Validates the conformity of setting by controlling stroke done during setting Detailled error reporting for better correction and prevention Ensures optimum setting of RIVKLE ®...
  • Page 15 Technical characteristics / Data Maximum stroke Maximum setting force Operating air pressure see chosen tool characteristics Weight without tooling (RIVKLE ® P1007, P2007 or P3007) Air consumption Noise level Production rate References Ø RIVKLE ® (steel) - For other material please see page 6 Code number RIVKLE ®...
  • Page 16: Rivkle

    RIVKLE ® – Standard force controlled installation power hand tool RIVKLE ® B2007 - Flexible and versatile battery tool Advantages: 3 kN to 22 kN (M3-M10 steel) Up to 800 cycles with 1 battery Internal testing done with 1 000 000 cycles BÖLLHOFF quality RIVKLE ®...
  • Page 17 Technical characteristics / Data Maximum stroke 7,0 mm 22 kN* Maximum setting force (* > 18 kN using appropriate accessory set) Battery Li-Ion / 14,4 V / 2,6 Ah 2,1 kg + 0,3 kg Weight without tooling (Tool + battery) Noise level <...
  • Page 18: Rivkle Epk Hp

    RIVKLE ® – Full control process power hand tool RIVKLE ® EPK Compact – RIVKLE ® EPK HP Advantages: 100% setting (installation) process control Pressure setting method High production rate Multilingual touchscreen Adjustable alarm and security devices Fault management (device / process) Theory The RIVKLE ®...
  • Page 19 Technical characteristics / Data RIVKLE ® EPK C RIVKLE ® EPK HP Code number 282 52 000 003 Electrical supply 230V - 50Hz Pneumatic supply 6 bar Setting force 6 to 21 kN 20 to 55 kN Setting stroke 7 mm 9 mm Noise level <...
  • Page 20: Mono Force Cartridges

    RIVKLE ® – Pressure controlled installation equipment RIVKLE ® - Force controller and cartridges CARTRIDGES It is possible to lock the setting force at a preset value on all RIVKLE ® PX007 & RIVKLE ® EPX009 tools using preset cartridge unit. We call it preset cartridge tool. 2 possibilities: 1- Order the complete tool already equipped with preset cartridge, adjusted by BÖLLHOFF using the generic code 282 52 000 005.
  • Page 21: How To? - Tooling Change

    RIVKLE ® – How to? Tooling change Nose cone Lock Nut Read the safety instruction manual. Disconnect from Mandrel power supply (battery or air). Anvil 1- Unscrew the nose cone from the tool Use the dedicated key from the tool box if necessary 2- To install the mandrel on the tool 2.1 - For RIVKLE ®...
  • Page 22: Tooling For Power Hand Tools

    RIVKLE ® – Tooling for power hand tools Ø RIVKLE ® RIVKLE ® P2005 / P1007 / P2007 236 11 *(1) – – Mandrel 376 11 – *(3) – – – 236 11 *(2) – – Anvil 376 11 – *(4) –...
  • Page 23 Accessories RIVKLE ® P2007 / RIVKLE ® P2005 RIVKLE ® P1007 P2007PN / P3007PN 282 59 010 984 + 50 mm + 100 mm 282 59 010 985 + 150 mm 282 59 010 986 + 50 mm 282 59 010 789 282 59 010 791 + 100 mm 282 59 010 790...
  • Page 24 Worldwide for you a strong partner – at 39 locations in 24 countries. Böllhoff Group Please find your local contact on www.boellhoff.com or contact us under fasteningtechnology@boellhoff.com Subject to technical change. Reprinting, even in extract form, only permitted with express consent. Observe protective note according to ISO 16016.