HY01RF Wireless Thermostat User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us
Product Specification
☆ Power: two AA* 1.5V alkaline batteries
☆ Range of temperature display: 0~40°C/32~104°F
☆ Insulating condition: Normal environment
☆ Running program: Set per 1 week as a cycle
☆ Installation: Wall mounted or on battery seat
☆ Working environment temperature: 0~70°C/32~122°F
☆ Range of temperature adjustment: 5~35°C/41~95°F
Displays & Buttons
Operation Key
set key: short press it to switch programme mode to manual mode. At programme mode,
NO:
symbols
press " "or" " to adjust the value, it will automatic enter into temporary manual mode
A
Increasing key
clock key: short pressing is setting clock, long pressing is setting programme
B
Keys locked/unlocked:press "
C
Decreasing key
Power on/off key
D
E
Run Mode
Factory Preset Mode
☆ Display accuracy: 0.5°C or 1°F
☆ Output: Switch relay
☆ Probe sensor: NTC(10k)1%
☆ Size(mm): 130*90*27 And 107*78*28
☆ Contact capacity: 16A/220V(RF electric heating)
5A/220V(RF gas boiler heating)
3A/220V(RF water heating)
represent
"and" "at the same time for 3 seconds
Monday to
the default
Interval
Friday
value
1st
06:00-08:00
20°C
2nd
08:00-11:30
15°C
3rd
11:30-13:30
15°C
4th
13:30-17:00
15°C
5th
17:00-22:00
22°C
6th
22:00-06:00
15°C
Press"
"to switch into programme mode (As shown in
Mode
picture one)
Programme illustration
5+2 programme function(advanced options contain of 6+1
and 7 days programme function, you can also cancel this
programme function), that is Monday to Friday is the same
setting value, and Saturday to Sunday is the same setting
Programming
value。Every day can be divided into 6 time interval
mode
Setting the programme value:long press"
programme setting mode, then short press"
press" "or" "to adjust value.
Press " " to enter into manual mode (As shown in picture
two), press" "or" "to adjust value.
Manual Mode
at programme mode,press "
it will automatic enter into temporary manual mode
Temporary
manual mode
Sending condition of Thermostat
Send once for 20 minutes
Press on/off key
Switch over output state
Communication instruction,be long bright display in normal communication and blinking display in abnormal
communication
Transceiver tips
Transceiver LED display instruction:
Power light (green light):it's bright when power on
Signal light(orange light):it's long bright within 10s after power on (match IP),signal light off when it receive
match,signal light is blinking within 10s when power off.
Load light/fault light (red light):
A、When no fault:light on when load output,light off when no load output
B、When fault: light is blinking and indication when fault
Saturday and
the default
Sunday
value
06:00-08:00
20°C
08:00-11:30
15°C
11:30-13:30
15°C
13:30-17:00
15°C
17:00-22:00
22°C
22:00-06:00
15°C
printscreen
explain
" to enter into
"to switch,
" or "
" to adjust the value,
Need help?