Summary of Contents for Whale INSTANT MATCH SDP134Tn
Page 1
® ® SDP134Tn Whale INSTANT MATCH with Bluetooth wireless technology Kit For Installation Videos please refer to the Whale website: www.whalepumps.com/psd WITH Technical Helpline: 0345 9090 912 This kit may be used with the following Mira Advance Shower: Mira Advance Flex Extra 8.7kw 1.1785.005 (J09Nn or J09N) www.youtube.com/WhaleHealthcare...
6. How do I register my warranty? www.whalepumps.com/psd Please complete and return the warranty registration form supplied with your pump, or complete the online form at: 0345 9090 912 drainagesupport@whalepumps.com Whale, 2 Enterprise Road, www.whalepumps.com/psd Bangor, Co. Down, BT19 7TA, N.Ireland...
Incorrect installation may invalidate the warranty. ® ® This kit has been designed for the pumping of shower waste water. The Whale Instant Match with Bluetooth wireless technology control unit uses the flow signal from the shower to measure the flow rate of water into the shower. The control unit uses the signals sent from the flow sensor to adjust the pump speed to match the flow of water from the shower.
Index lumbing of the Waste Pipe User warnings End user help Principles of operation Plumbing specification Plumbing gulley Plumbing of waste pipe Installation Transformer settings ® Bluetooth wireless technology setup ® Bluetooth wireless technology unpairing Hardwired setup Purge cycle Swapping pump & transformer on backplate Safety warning Installation testing and repair EU declaration of conformity...
IP45 compliant. Locate pump in accordance with BS7671 2018 Part 7 (18th Edition). The Whale Pump is rated to IP45 and the Whale transformer is rated to IP65. We recommend the pump and transformer are installed in bathroom zones 2 and 3.
Fig 1.2 • Rotate the pump head if necessary. Loosen clamping ring screw, rotate and retighten as shown. See Fig 1.2 • Before commissioning the shower and running water through the system, ensure that the shower area and gulley are completely free of building debris, especially tile grout, screed material and latex.
32mm (1 ") McAlpine examples and the McAlpine catalogue for other variants. Use with a Macerator Pump ® • Discharge from the Whale pump must go into the top of the macerator box. Do not use the bottom entries. 32mm ") 1 /4 See Fig 1.6...
Installation umbing of the Waste Pipe 1. Plumbing drainage pipe • Run 15mm pipe from gulley to pump inlet (max 3m). • Use slow radius bends where possible. Full size elbows are acceptable, not stem or Male/Female elbows. Where possible avoid attaching elbows directly to the pump. 2.
Page 9
3. Mounting your pump to the wall • Mark the hole centres through unit backplate. • Drill holes in wall and fit wall plugs (if necessary). Use 6mm masonry bit. • Secure the backplate to the wall using supplied screws. •...
Page 10
10 seconds overrun and 15mm inlet pipe size. For other settings please refer to Transformer settings (see page 11). • Refit the hatch and tighten the screws to make the transformer water resistant. The Whale Instant Match ® with Bluetooth ® wireless technology transformer includes...
7. Fit and secure pump cover when required to complete set up 8. Optional external pump overrun switch Use a retractive switch to briefly activate the pump. This facility is for use when the wet area is being cleaned, or for ritual cleansing.
® • The Bluetooth function of the Whale Instant Match transformer will only work with the Mira Advance Flex ® Extra (J09Nn or J09N) shower. Previous Whale Instant Match Wireless transformers cannot be connected ® ® wirelessly to the Bluetooth wireless technology enabled Mira Advance shower ®...
Page 13
2. Transformer set up • Switch the mains electric supply to the transformer ON and wait to hear the audible beep from the transformer. The light on the transformer will now flash red to indicate ® that a Bluetooth connection has not yet been established •...
Page 14
PCB board may require the Bluetooth wireless technology connection between ® the shower and Whale Instant Match transformer to be terminated and paired again once the work has been completed. To unpair the transformer from the shower, please follow these steps.
Bluetooth wireless technology unpairing Mira Advance Flex Extra (J09Nn or J09N) In cases where the Mira shower needs to be paired to a new transformer or re-paired with an existing transformer, the following steps to unpair the shower must be taken. 1.
45 DEG C the Mira Advance (J09Nn or J09N) has been set to the “OFF” RESERVED 1 position as per the diagram shown. NOTE: Switch settings for other Whale transformers can be RESERVED 2 found on page 17. BLE PUMP ENABLE...
Page 17
755.210 Wired Pump Mode - ON Hardwired 755.299 Wired Pump Mode - OFF Hardwired Older models of Whale transformer can be connected to the 755.349 Wired Pump Mode - OFF Hardwired ® Mira Advance Flex Extra (J09Nn or J09N)' shower. This table 755.399...
• External components for service are jumper settings only. • Where there is damage to the transformer or cabling, contact your Whale distributor for a replacement. • Do not connect mains power to the pump as this will cause permanent damage and will result in an electrical hazard.
Installation Testing & Repair CHECK TRICUSPID VALVE - Remove the tricuspid valve holder screwed onto the pump discharge. Remove the rubber valve and assess its condition. If it is worn or stiff then change The pump system is designed not to require maintenance. If and re-test.
Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Maximum Head & Lift: 1.5m Whale. Whale’s policy is one of continuous improvement and we reserve the Transformer right to change specifications without prior notice. Illustrations are for guid- ance purposes only.
List of Parts included in the kit umbing of the Waste Pipe Item Part No. Shower Drain Pump SDS021T Transformer Instant Match Bluetooth SDS236T Pump Cover base 755.610 Wet Floor Gulley (vinyl floors) 755.274 Tray Gulley (50mm) 755.108 Tricuspid valve 755.57 Rubber Waste adapter 2 parts 22mm –...
Page 23
Pump Base Standoffs Where pipe runs make installation of the pump base difficult we recommend the use of a Space - Plug (Available from SCREWFIX Version 30-50mm shown below)
Whale INSTANT MATCH Kit Fault Diagnosis ® What is the fault? Pump will not start Pump will not stop The transformer allows the pump to Ensure power is connected and switched on. over-run for up to 60 seconds. If the pump continues to run after Press the TEST button on top of the transformer.
Page 25
Pump does not pump properly Ensure gulley is not blocked and that fittings are pushed home and airtight. Re-test and if pump does not pump properly, remove inlet coupling and press the test button on the transformer, or run the shower into the sink to run the pump.
Plumbing Specification WASTE PIPE FORMED BEND Maximum pipe length is 3m from gulley to pump. Pipe from gulley to pump must be in 15mm. MIN 1:40 FALL (Do not use 22mm pipework for 1M (MAX) electric showers. This will increase gulley noise.) WARNING 15MM DIA PIPE USE ONLY 22MM...
Page 27
Pump - SDS021T 310mm 255mm 127mm TRICUSPID VALVE Contact the Technical Helpline If you need further assistance: 0345 9090 912...
Need help?
Do you have a question about the INSTANT MATCH SDP134Tn and is the answer not in the manual?
Questions and answers