The thermostat provides an auxiliary heating output that can act as a second stage of heating when controlling ambient temperature.
If the room temperature is too far from the setpoint or the main stage of heating has difficulties raising the temperature, the auxiliary output activates the secondary heating source to reach the set temperature.
Both outputs can control different types of heating load and can be configured in the user settings.
Electric baseboard
Electric floor heating with electric baseboard on the 2nd heating stage
Hot water valve
Only for control applications in floor (F) mode or with floor limit.
When installing your floor heating system: add a second sensor in the floor and store the tip in the thermostat housing. This additional sensor can be plugged in and used as a replacement without haltering your floor heating system.
Increasing or lowering the temperature
To adjust the temperature, press or
. The requested temperature will blink to confirm the new setpoint.
Lower the setpoint to its minimum and hold the button for 10 seconds to access the menu.
Press the or the
button to change the setting.
Press the and the
buttons simultaneously to save and go to the next parameter. Continue to press until the end of the list to exit the menu.
# | Name | Parameters & settings | Display |
1 | Display | Temperature format °C or °F – (Default: °F) | ![]() |
2 | Control | Control mode of thermostat A (Air), F (Floor) – (Default: A) | ![]() |
3 | Setpoint Min | Minimum setpoint 41°F to 97°F – (Default: 41°F) | ![]() |
4 | Setpoint Max | Maximum setpoint 41°F to 97°F – (Default: 97°F) | ![]() |
5 | Limit Floor Max | Maximum floor temperature limit (Only visible in A mode) 45°F to 97°F or OFF – (Default: OFF) | ![]() |
6 | FLR Min Limit | Minimum floor temperature limit (Only visible in A mode) 41°F to 93°F or OFF (default: OFF) | ![]() |
7 | Air Max Limit | Maximum ambient temperature limit (Only visible in F mode) 41°F to 97°F or OFF (default: OFF) | ![]() |
8 | 1st Stage Cyc | Cycle lenght / Main output 15 sec, 5 min, 10 min, 15 min, 20 min, 25 min, 30 min – (Default: 15 min) | ![]() |
9 | Aux 2nd Stage Cyc | Cycle lenght / Auxiliary output OFF, 15 sec, 5 min, 10 min, 15 min, 20 min, 25 min, 30 min – (Default: OFF) | ![]() |
10 | Backlight | Backlight control ON, OFF or BED – (Default: ON) ON (backlight always active, will dim according to ambient light) OFF (will only turn on when a button is pressed) BED (bedroom mode - backlight will dim according to ambient light and will turn OFF below 20% of luminosity) | ![]() |
11 | Sensor | Floor sensor 10K or 12K – (Default: 10K) | ![]() |
12 | PE | Circulator pump's anti-seizure ON or OFF (Default: OFF) | ![]() |
Minimum cycle length | 0.15 | 5 | 10 | 15 | 20 | 25 | 30 |
Convector or baseboard heater activated by electronic relay (SSR) | ![]() | ||||||
Fan-forced convector activated by electronic relay (SSR) | ![]() | ![]() | |||||
Fan-forced convector or baseboard heater activated by mechanical relay | ![]() | ![]() | |||||
Hydronic heating pump system | ![]() | ![]() | ![]() | ![]() | |||
Furnace | ![]() | ![]() | ![]() | ![]() |
To put the thermostat in OFF mode, hold the buttons and
for 10 seconds.
To exit the OFF mode, hold the buttons and
for 10 seconds or raise/lower the setpoint.
What should I do if the E1F code appears on my thermostat's display?
The E1F code means that the thermostat is in "Floor" mode and there is no connected sensor. If your thermostat is not intended to control a heated floor, change the thermostat's control mode for the "A mode".
Operating voltage: 24 Vac
Maximum load: 1 Amp
Setpoint range: 5 ˚C to 36 ˚C (41 ˚F to 97 ˚F)
Display range: 0 ˚C to 70 ˚C (32 ˚F to 99 ˚F)
Resolution: ± 0,5 ˚C (± 1 ˚F)
Storage: -20 ˚C to 50 ˚C (-4 ˚F to 122 ˚F)
Auxiliary output: 24 Vac / Vdc / 0.1 A
Compatible with:
3-year limited warranty
SINOPE TECHNOLOGIES INC. warrants the components of their products against defects in material and workmanship for a 3-year period from the date of purchase, under normal use and service, when proof of purchase of such is provided to the manufacturer. This warranty does not cover any transportation costs that may be incurred by the consumer. Nor does it cover a product that has been improperly installed, misused or accidentally damaged.
The obligation of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty, will be to supply a new unit and this releases the manufacturer from paying the installation costs or other secondary charges linked to replacing the unit or the components.
For more information, visit our Website:
www.sinopetech.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Sinope TH1400NP - 24 Vac Non-Programmable Low Voltage Thermostat Manual