Advertisement
Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www.P65warnings.ca.gov.
All information, illustrations, and specifications in this manual were in effect at the time of publishing. The illustrations used in this manual are intended as representative reference views only. We reserve the right to make any specification or design change without notice.
All rights reserved. No reproduction allowed in any form without written permission from Westinghouse Outdoor Power Equipment, LLC.
Read this manual before using or performing maintenance on this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
Running Watts: | 5300 Gas / 4800 Propane |
Peak Watts: | 6600 Gas / 5800 Propane |
Rated Voltage: | 120V/240V |
Rated frequency: | 60 Hz @ 3600 RPM |
Phase: | Single phase |
Total Harmonic Distortion: | ≤ 23% |
Engine Displacement: | 274 cc |
Starting Type: | Recoil |
Fuel Capacity: | 4.7 Gallons (18 Liters) |
Fuel Type: | Unleaded gasoline 87–93 octane* |
Oil Capacity: | 0.74 Quart (0.7 Liter) |
Oil Type: | SAE 10W-30 |
Spark Plug: | 97108 (F7TC) |
Spark Plug Gap: | 0.024 – 0.032 in. (0.60 – 0.80 mm) |
Valve Intake Clearance: | 0.0031 – 0.0047 in. (0.08 – 0.12 mm) |
Valve Exhaust Clearance: | 0.0051 – 0.0067 in. (0.13 – 0.17 mm) |
AC Grounding System: | Neutral bonded to frame |
Voltage Regulator: | AVR |
Alternator Type: | Brushed |
Maximum Ambient Temperature: | 104°F (40°C) |
Certifications: |
|
*Ethanol content of 10% or less. DO NOT use E15 or E85.
UPDATES
Scan the following QR code with your smartphone camera to be directed to the link.
NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). If needed, this product can be operated at temperatures ranging from 5°F (15°C)–122°F (50°C) for short periods. If the product is exposed to temperatures outside of this range during storage, it should be brought back within this range before operation. This product must ALWAYS be operated outdoors in a well-ventilated area and far away from doors, windows, and other vents. Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F (6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to register your Westinghouse generator.
You can register by:
Keep your purchase receipt for trouble-free warranty coverage.
The words DANGER, WARNING, CAUTION, and NOTICE are used throughout this manual to highlight important information. Make sure that the meanings of this safety information is known to all who operate, perform maintenance on, or are near the generator.
This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Read and abide by the message that follows the safety alerts symbol.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal property, and/or the environment, or cause the equipment to operate improperly.
Note: Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended.
Follow all safety information contained in this manual and on the generator.
Symbol | Description |
Safety Alert Symbol | |
![]() | Electrocution Hazard |
![]() | Asphyxiation Hazard |
![]() | Burn Hazard. DO NOT touch hot surfaces. |
Electrical Shock Hazard | |
![]() | Fire Hazard |
![]() | Maintain Safe Distance |
![]() | Lifting Hazard |
![]() | Read Manufacturer's Instructions |
![]() | DO NOT Operate in Wet Conditions |
![]() | Ground. Consult with electrician to determine grounding requirements before operation. |
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
CORRECT USAGE
Example location to reduce risk of carbon monoxide poisoning ONLY use outside and downwind, far away from windows, doors and vents. Direct exhaust away from occupied spaces
INCORRECT USAGE
Do not operate in any of the following locations:
Near any door, window, or vent
NOTICE
Install battery-powered carbon monoxide detectors or plug-in carbon monoxide detectors with battery back-up in living areas.
Fire and electrocution hazard. DO NOT connect to a building's electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.
Electrocution hazard. NEVER use the generator in a location that is wet or damp. NEVER expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
GENERAL SAFETY PRECAUTIONS
FUEL SAFETY
GASOLINE AND GASOLINE VAPOR (GAS)
Fire and explosion hazard. Gasoline and LPG/propane are highly explosive and flammable and can cause severe burns or death.
LIQUID PETROLEUM GAS (LPG/PROPANE)
Fire and explosion hazard. NEVER use a gas container, LPG/propane connector hose, LPG/propane tank or any other fuel item that appears to be damaged.
Fire and explosion hazard. Only use approved LPG/ propane tanks with an Overfilling Prevention Device (OPD) valve. ALWAYS keep the tank in a vertical position with the valve on top and placed at ground level on a flat surface. DO NOT allow tanks to be near any heat source. When transporting and storing, turn the propane tank valve to the fully closed position and disconnect the tank. Make sure to ALWAYS cover the generator inlet and tank outlet with protective plastic caps.
Fire and explosion hazard. If there is a strong smell of propane while operating the generator, fully close the LPG/propane tank valve immediately. Once the propane is off, use soapy water to check for leaks on the hose and connections on the tank valve and the generator. DO NOT smoke or light a cigarette or check for leaks using any open flame source such as a match or lighter. If a leak is found, contact a qualified technician to inspect and repair the LPG/propane system before using the generator.
When starting the generator:
When transporting or servicing the generator:
When storing the generator:
DATA CENTER
Voltage:
Displays current voltage output.
Frequency (Hz):
Displays power output frequency in Hertz.
Lifetime Hours:
Displays the lifetime run hours.
Run Time/Maintenance:
Displays current run time. Resets to zero when shut down. Maintenance reminder displayed
Maintenance Codes:
P25: Change engine oil
P50: Clean air filter, Change engine oil
P100: Change engine oil, clean air filter, replace fuel filter
Weight hazard. ALWAYS have assistance when lifting the generator.
CARTON CONTENTS
Item | Quantity |
| 2 |
| 4 |
| 2 |
| 2 |
| 2 |
| 2 |
If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.
NOTICE
Assembling the generator will require lifting the unit on one side. Install the mounting feet and wheel before adding fuel or oil.
NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT OIL. DO NOT attempt to crank or start engine before it has been properly serviced with recommended oil. Failure to add engine oil before starting will result in serious engine damage.
NOTICE
Use of 2-stroke/cycle oil or other unapproved oil types can cause severe engine damage that is not covered under warranty.
The included, recommended oil type for typical use is 10W-30 engine oil. If running the generator in extreme temperatures, refer to the following chart.
Fire and explosion hazard. NEVER use a gasoline container, gasoline tank, propane connector hose, propane tanks, or any other fuel item that is broken, cut, torn or damaged.
Fire and explosion hazard. DO NOT overfill fuel tank. Fill only to the red fill ring located in the in-tank fuel screen filter. Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard.
Fire and explosion hazard. NEVER refuel the generator while the engine is running. ALWAYS turn the engine off and allow the generator to cool for two minutes before refueling.
NOTICE
DO NOT use E15 or E85 fuel in this product. Engine or equipment damage caused by stale fuel or E85 E15 the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty. Only use unleaded gasoline containing up to 10% ethanol.
FUEL REQUIREMENTS
USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow the manufacturer's instructions for use.
ALWAYS mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator. Run the generator for five minutes to allow the stabilizer to treat the entire fuel system.
FILLING THE FUEL TANK
NOTICE
Fuel can damage paint and plastic. Use caution when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty.
NOTICE
Clean the fuel screen filter of debris before and after each fueling. Remove the fuel screen filter by slightly compressing it while removing it from the fuel tank.
NOTICE
NOTICE
Explosion hazard. DO NOT start generator if you smell propane. ALWAYS fully close the propane tank valve and disconnect the LPG/propane hose from the generator when not in use.
Keep the propane tank valve in the fully closed position unless in use.
Read and understand all safety information before starting the generator.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
NEVER operate the generator inside any building, including garages, basements, crawlspaces, sheds, enclosure, or compartment, including the generator compartment of a recreational vehicle.
Electrocution hazard. NEVER use the generator in a location that is wet or damp. NEVER expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution
Fire hazard. Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could block cooling vents or the air intake system. Allow the generator to cool for 30 minutes before transport or storage.
The generator should be on a flat, level surface at all times (Even while not in operation). The generator must have at least 5 ft. (1.5 m) of clearance from all combustible material.
DO NOT operate the generator in the back of a SUV, camper, trailer, truck bed (regular, flat, or otherwise), under stairs, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation.
Asphyxiation hazard. Place the generator in a wellventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning the generator.
Shock hazard. Failure to properly ground the generator can result in electric shock.
NOTICE
Only use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.
The generator neutral is bonded to the frame. There is a permanent conductor between the generator (stator wire) and the frame. If this generator will be used only with cord and plug equipment connected to the receptacles mounted on the generator, National Electric Code does not require that the unit be grounded. However, other methods of using the generator may require grounding to reduce the risk of shock or electrocution. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
DISCONNECTING THE BONDED NEUTRAL
The bonded neutral should only be removed under specific circumstances. Consult a qualified electrician to determine if your situation requires disconnecting the bonded neutral.
Apply a new "NEUTRAL UNBONDED" Label over the "NEUTRAL BONDED TO FRAME" label on the front of the control panel.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes over 5,000 ft. (1524 m). Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. Operation of the engine at altitudes below 2,000 ft. (762 m) with the high altitude kit is not recommended.
High Altitude Carburetor Kit Part# 518965
High Altitude DF Regulator: Part# 518516
Note: You must purchase both the Dual Fuel Regulator and Carburetor Kit for proper high altitude operation.
VOLTAGE SELECTOR SWITCH
The 120V/240V selector switch, which gives the user the ability to double the amperage in the generator for more demanding applications. The voltage selector switches the dual 120V AC windings of the generator to produce 120V or 240V. If a 240V appliance is connected to the 4-prong L14-30R receptacle, the switch must be in the "240V" position. The 120V only outlets will not output power when the Voltage Selector is in the 240V position.
Only change the Voltage Selector Switch with the generator OFF. DO NOT switch the voltage while the generator is running or powering appliances.
Position the fuel selector switch on the front control panel to the desired fuel choice.
Turn the fuel selector switch fully upward for gasoline operation.
Turn the fuel selector switch fully downward for propane operation.
For proper break-in, DO NOT exceed 50% of the rated running watts (2650 watts) during the first five hours of operation. Vary the load occasionally to allow stator windings to heat and cool and help seat the piston rings.
Verify that:
Fire and explosion hazard. DO NOT move or tip the generator during operation.
Fire and explosion hazard. ALWAYS turn the propane tank valve to the fully closed position if not running the generator on propane.
Fire and explosion hazard. DO NOT add gasoline to the fuel tank or connect the LPG/propane hose to the generator while the generator is in operation. The fuel source can be switched while the engine is running if a propane tank is connected to the generator BEFORE operation.
GASOLINE TO PROPANE
Load capacity is reduced when running on propane. Make sure the generator can supply enough (running) and surge (starting) watts for the items you are powering before switching to propane.
PROPANE TO GASOLINE
If the engine stops when switching fuel sources, disconnect all loads then restart the unit on the fuel source of choice.
If the generator will be used on an infrequent or intermittent basis (more than one month before next use), refer to the Storage section of this manual for information regarding fuel deterioration.
The circuit breakers will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. If an AC circuit breaker switches OFF automatically, check that the appliance is working correctly and it does not exceed the rated load capacity of the circuit before resetting the AC circuit breaker ON.
NOTICE
DO NOT overload the generator's capacity. Exceeding the generator's wattage/amperage capacity can damage the generator and/or electrical devices connected to it.
Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the same time. The total power requirements (Volts x Amps = Watts) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model or serial number. To determine power requirements:
Tool or Appliance | Running Watts* | Starting Watts* |
RV Air Conditioner (11,000 BTU) | 1010 | 1600 |
TV (Tube Type) | 300 | 0 |
RV Refrigerator | 180 | 600 |
Radio | 200 | 0 |
Light (75 Watts) | 300 | 0 |
Coffee Maker | 600 | 0 |
2590 Total Running Watts* | 1600 Highest Starting Watts* | |
Total Running Watts | 2590 | |
Highest Starting Watts | + 1600 | |
Total Starting Watts Needed | 4190 |
*Wattages listed are approximate. Verify actual wattage.
To prolong the life of the generator and attached devices, use care when adding electrical loads to the generator. There should be nothing connected to the generator outlets before starting the engine. The correct and safe way to manage generator power is to sequentially add loads as follows:
Tool or Appliance | Estimated Running Watts* | Estimated Starting Watts* |
Incandescent Lights (4 Quantity x 75 Watts) | 300 | 0 |
TV (Tube Type) | 300 | 0 |
Sump Pump (1/3 hp) | 800 | 1300 |
Refrigerator or Freezer | 700 | 2200 |
Well Pump (1/3 hp) | 1000 | 2000 |
Furnace (1/2 hp) | 800 | 2350 |
Radio | 200 | 0 |
Drill (3/8", 4 amps) | 440 | 600 |
Circular Saw (Heavy Duty, 7-1/4") | 1400 | 2300 |
Miter Saw (10") | 1800 | 1800 |
Table Saw (10") | 2000 | 2000 |
*Wattages listed are approximate. Verify actual wattage.
Asphyxiation hazard. Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings. If an extension cord running directly into your home is used to power indoor items, there is a risk of carbon monoxide poisoning to people inside the home. ALWAYS use battery-powered carbon monoxide detector (s) that meet current UL 2034 safety standards when running the generator. Regularly check the detector (s) battery.
Asphyxiation hazard. When operating the generator with extension cords, make sure the generator is located in an open, outdoor area, far away from occupied spaces with exhaust pointed away.
Fire and electrocution hazard. NEVER use worn or damaged extension cords. Damaged or overloaded extension cords could overheat, arc, and burn resulting in death or serious injury.
Before connecting an AC appliance or power cord to the generator:
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for outdoor use that are rated for the electrical load.
![]() | ||
Total | Minimum Gauge, Outdoor Rated | |
Amperage | Up to 50 FT (15 M) | Up to 100 FT (30 M) |
Up to 10A | ![]() | ![]() |
Up to 15A | ![]() | ![]() |
Up to 20A | ![]() | ![]() |
Up to 30A | ![]() | ![]() |
Up to 35A | ![]() | ![]() |
Weight hazard. ALWAYS have assistance when lifting the generator.
Fire hazard. DO NOT up-end the generator or place it on its side. Fuel or oil can leak and damage to the generator may occur.
Accidental start-up. Disconnect the spark plug boot from the spark plug when performing maintenance on the generator.
Regular maintenance will improve performance and extend the service life of the generator. Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions as noted below.
Before Each Use |
Check engine oil |
After First 25 Hours or First Month |
Change engine oil |
After 50 Hours or Every 6 Months |
Change engine oil1 Clean air filter2 |
After 100 Hours or Every 6 Months |
Inspect/clean spark arrestor Inspect/clean spark plug Fuel valve maintenance Inspect/adjust valve clearance3 |
After 300 Hours or Every Year |
Replace spark plug Replace air filter |
1 Change oil every month when operating under heavy load or in high temperatures.
2 Clean more often under dirty or dusty conditions.
Replace air filter if it cannot be adequately cleaned.
3 Recommend service to be performed by authorized Westinghouse service dealer.
Maintenance reminder codes will be shown on the Data Display based on unit Lifetime Hours. The maintenance codes will be displayed until the unit is turned off. Refer to the Maintenance section for specific procedures.
Maintenance Code | Required Maintenance |
P25 | Change engine oil |
P50 | Change engine oil, clean air filter |
P100 |
|
Description | Part Number |
Air filter | 5941 |
Oil drain plug crush washer | 94007 |
Spark arrestor | 6790 |
Spark plug | 97108 (F7TC) |
The air filter must be cleaned after every 50 hours of use or six months (frequency should be increased if the generator is operated in a dusty environment).
Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
NOTICE
ALWAYS use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.
When using the generator under dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions.
Check the engine oil level before each use or every 8 hours of operation.
When using the generator under dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Change the oil while the engine is still warm from operation.
NOTICE
DO NOT pollute. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.
Inspect and clean the spark plug after every 100 hours of use or six months. Replace the spark plug after 300 hours of use or every year.
Allow the muffler to cool completely before servicing the spark arrestor. Check and clean the spark arrestor after every 100 hours of use or six months. Failure to clean the spark arrestor will result in degraded engine performance.
Proper storage preparation is required for trouble-free operation and generator longevity.
NOTICE
Gasoline stored for as little as 30 days can deteriorate, causing gum, varnish, and corrosive buildup in fuel lines, fuel passages, and the engine. This corrosive buildup restricts the flow of fuel, which can prevent the engine from starting after a prolonged storage period. The use of fuel stabilizer significantly increases the storage life of gasoline. Full-time use of fuel stabilizer is recommended. Follow the manufacturer's instructions for use.
STORAGE TIME | RECOMMENDED PROCEDURE |
Less than 1 month | No service required. |
2 to 6 months | Fill with fresh gasoline and add gasoline stabilizer. Drain the carburetor float bowl. |
6 months or longer | Drain the fuel tank and carburetor float bowl. |
SHORT TERM STORAGE
LONG TERM STORAGE
Even properly stabilized fuel can leave residue and cause corrosion if left long term. If storing the generator for two to six months, drain the float bowl to prevent gum and varnish buildup in the carburetor.
DRAINING THE FLOAT BOWL
DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain the fuel tank to prevent fuel separation, deterioration, and deposits in the fuel system.
The fuel valve is equipped with an inline fuel filter. The fuel valve filter does not require servicing if the unit is properly maintained with fresh, clean fuel. If fuelrelated troubleshooting is required, perform fuel valve maintenance.
NOTICE
Checking and adjusting valve clearance must be done when the engine is cold.
Intake Valve | Exhaust Valve | |
Valve Clearance | 0.0031 – 0.0047 in (0.08 – 0.12 mm) | 0.0051 – 0.0067 in (0.13 – 0.17 mm) |
Torque | 8-12 N•m | 8-12 N•m |
PROBLEM | POSSIBLE CAUSE | CORRECTION |
Engine will not start | Out of fuel. | Refuel. |
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. | Drain the fuel tank. Refuel with fresh gasoline. | |
Dirty air filter. | Clean the air filter. | |
Low engine oil level stopped generator. | Check engine oil level. Add engine oil if low. | |
Spark plug wet with fuel (flooded engine). | Wait five minutes. Turn Run/Stop switch to the OFF position. Pull recoil handle rapidly several times. If the generator does not start, remove spark plug and dry. | |
Spark plug faulty, fouled, or improperly gapped. | Gap or replace the spark plug. Reinstall. | |
Fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Choke partially open or closed. | Fully open or close the choke. | |
Engine starts, then shuts down | Out of fuel. | Refuel. |
Incorrect engine oil level. | Check engine oil level. | |
Dirty air filter. | Clean the air filter. | |
Contaminated fuel. | Drain the fuel tank. Refuel with fresh gasoline. | |
Defective low oil level switch. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Engine lacks power | Air filter restricted. | Clean or replace air filter. |
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. | Drain the fuel tank. Refuel with fresh gasoline. | |
Fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Engine runs rough or bogs when load applied | Dirty air filter. | Clean the air filter. |
Generator overloaded. | Unplug some devices. | |
Faulty power tool or appliance. | Replace or repair tool or appliance. Stop and restart the engine. | |
Fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
No power at AC receptacles | AC circuit breaker/s tripped. | Check AC loads and reset circuit breaker/s. |
Faulty power tool or appliance. | Replace or repair tool or appliance. Stop and restart the engine. | |
Faulty generator. | Contact Westinghouse customer service tollfree at 1 (855) 944-3571. | |
Frost on the propane tank or regulator | If the temperature of the propane tank drops below the dew point, condensation on the tank may turn to frost or ice. This typically occurs in humid conditions. | Providing all the propane fuel handling equipment is functioning normally, no correction is needed. |
The Propane tank is not equipped with an Overfilling Prevention Device (OPD). | If you suspect your propane fuel tank is not equipped with an OPD device, discontinue operation immediately and replace the propane fuel tank with a propane tank equipped with a an OPD. | |
Propane fuel tank overfilled. | If you suspect your propane fuel tank has been overfilled, discontinue operation immediately and return the propane fuel tank to the place of purchase or refilling. | |
Propane fuel smell | Fuel regulator or fuel hose and fittings not securely sealed. | Using a soap solution check each connection and tighten as needed. |
Propane fuel regulator vent active. | The propane fuel regulator is equipped with a vent that will allow a small amount of propane fuel vapor to escape from the regulator when the propane tank valve is opened. This can be normal providing the venting of the propane is brief. If you suspect that this is abnormal, immediately discontinue use and have the propane regulator inspected by a qualified technician. | |
Residual fuel from the carburetor dispersing after operation. | Normal, no correction is needed. | |
Poor performance or engine stalling on Propane | Propane fuel line kinked or crushed. | Inspect propane fuel line and remove kinks or other obstructions. |
Fuel selector valve not properly positioned. | Rotate the fuel valve fully until the pointer is directly in line with the desired fuel. | |
Gasoline not purged from the carburetor before switching to propane. | Close the propane fuel tank valve. Move the fuel selector switch to gas. Start the engine and allow the engine to run until the gasoline has been consumed in the carburetor. Begin propane start up procedure. |
EXPLODED VIEW A
NO. | PART# | DESCRIPTION |
1 | CRANKCASE ASSEMBLY | |
1.1 | 400201 | CRANKCASE |
1.2 | 93509 | CRANKCASE OIL SEAL |
1.3 | 93520 | CRANKCASE OIL SEAL |
1.4 | 403901 | GOVERNOR SHAFT |
1.5 | 96804 | GOVERNOR SHAFT OIL SEAL |
1.6 | 383902 | RETAINING CLIP |
1.7 | 245106 | OIL SENSOR ASSEMBLY |
1.8 | 91329 | BOLT M6*16 |
1.9 | 404301 | GOVERNOR GEAR ASSEMBLY |
1.10 | 93012 | AXLE BEARING |
2 | ALTERNATOR ASSEMBLY | |
2.1 | 402002 | CAMSHAFT ASSEMBLY |
2.2 | 406101 | VALVE LIFTER |
2.3 | 401901 | PUSH ROD |
3 | 400301 | CRANKSHAFT |
4 | CRANKCASE COVER ASSEMBLY | |
4.1 | 93509 | CRANKCASE OIL SEAL |
4.2 | 240904 | CRANKCASE LOCATING PIN |
4.3 | 96222 | CRANKCASE GASKET |
4.4 | 400101 | CRANKCASE COVER |
4.5 | 91347 | BOLT M8*30 GB/T5787-1986 |
4.6 | 245601-295 | DIPSTICK |
4.7 | 93012 | AXLE BEARING |
5 | SPEED CONTROL BRACKET ASSEMBLY | |
5.1 | 91329 | BOLT M6*16 |
5.2 | 404001 | SPEED REGULATING ARM |
5.3 | 91822 | BOLT M6*21 |
5.4 | 90016 | NUT M6 |
5.5 | 402701 | THROTTLE LEVER |
5.6 | 404201 | SPRING C |
5.7 | 404101 | SPRING B |
5.8 | 407701 | SPEED CONTROL BRACKET |
6 | LOWER GUARD ASSEMBLY | |
6.1 | 407601 | UNDER GUARD |
6.2 | 91325 | BOLT M6*12 |
7 | SHROUD ASSEMBLY | |
7.1 | 407501 | WIND-LEAD-COVER |
7.2 | 91325 | BOLT M6*12 |
8 | 97108 | SPARK PLUG |
9 | CYLINDER HEAD COVER ASSEMBLY | |
9.1 | 91329 | BOLT M6*16 |
9.2 | 96225 | HEADCOVER GASKET |
9.3 | 401102 | CYLINDER HEAD INTERNAL COVER |
9.4 | 96226 | CYLINDER HEAD INTERNAL COVER GASKET |
9.5 | 401101 | CYLINDER HEAD COVER |
9.6 | 92036 | SCREW |
9.7 | 95603 | BREATHER TUBE |
9.8 | 94435 | BREATHER TUBE CLIP |
10 | CYLINDER HEAD ASSEMBLY | |
10.1 | 401002 | CYLINDER HEAD |
10.2 | 401701 | INTAKE VALVE |
10.3 | 405901 | EXHAUST VALVE |
10.4 | 406001 | VALVE SPRING |
10.5 | 402101 | ROCKER ARM |
10.6 | 91818 | BOLT |
10.7 | 402201 | VALVE RETAINER ASSEMBLY |
10.8 | 241806 | VALVE SEAL |
10.9 | 241817 | VALVE SPRING RETAINER |
10.10 | 329930 | VALVE LOCK CLAMP |
10.11 | 241804 | TOP CAP |
10.12 | 91022 | DOUBLE END BOLT M6*95 |
10.13 | 91007 | DOUBLE END BOLT M8*38 |
10.14 | 260901 | CYLINDER HEAD LOCATING PIN |
10.15 | 96223 | CYLINDER HEAD GASKET |
10.16 | 91452 | BOLT M10 |
10.17 | 96235 | GASKET |
10.18 | 402301 | CARBURETOR CONNECTION BLOCK |
11 | PISTON & PISTON RING ASSEMBLY | |
11.1 | 401201 | PISTON |
11.2 | 401601 | PISTON RING ASSEMBLY |
11.3 | 401501 | CONNECTING ROD ASSEMBLY |
11.4 | 405501 | PISTON PIN |
11.5 | 241301 | PISTON PIN RING |
12 | CARBURETOR ASSEMBLY | |
12.1 | 94403 | FUEL LINE CLAMP |
12.2 | 402804-295 | CARBURETOR ASSEMBLY |
12.3 | 95727L | FUEL LINE |
12.4 | 517917 | LOW PRESSURE HOSE |
12.5 | 599302 | FUEL LINE CLAMP |
13 | AIR CLEANER ASSEMBLY | |
13.1 | 91329 | BOLT M6 |
13.2 | 90016 | NUT M6 |
13.3 | 402901 | AIR CLEANER ASSEMBLY |
14 | IGNITOR ASSEMBLY | |
14.1 | 97552 | IGNITER |
14.2 | 91331 | BOLT M6 |
15 | FLYWHEEL ASSEMBLY | |
15.1 | 244508 | STARTER PULLEY |
15.2 | 240401 | FLYWHEEL ASSEMBLY |
15.3 | 404601 | IMPELLER |
15.4 | 90003 | NUT |
16 | RECOIL STARTER ASSEMBLY | |
16.1 | 91325 | BOLT M6 |
16.2 | 404706-221A | STARTER ASSEMBLY |
16.3 | 5943 | RECOIL HANDLE |
16.4 | 5942-221 | RECOIL STARTER ASSEMBLY |
16.5 | 240801 | CABLE CLIP |
17 | 91816 | BOLT M10*1.25*15 |
18 | 94007 | OIL DRAIN BOLT WASHER |
19 | 96224 | CARBURATOR GASKET |
20 | 94324 | STEEL WASHER |
21 | 5941 | AIR FILTER ELEMENT |
EXPLODED VIEW B
NO. | PART# | DESCRIPTION |
1 | FRAME ASSEMBLY | |
1.1 | 774058-116 | FRAME |
1.2 | 531318 | DAMPING BEARING |
1.3 | 90016 | NUT M6 |
1.4 | 90018 | NUT M8 |
1.5 | 91325 | BOLT M6X12 |
1.6 | 91327 | BOLT M6X12 |
1.7 | 544301 | GROUND WIRE |
1.8 | 96120 | WASHER |
1.9 | 530324-116 | FUEL TANK BRACKET |
1.10 | 94002 | TOOTH WASHER |
2 | PRESSURE REDUCING VALVE ASSEMBLY | |
2.1 | 91325 | BOLT M6X12 |
2.2 | 91327 | BOLT M6X12 |
2.3 | 96120 | GASKET |
2.4 | 517336 | LOW PRESSURE LINE |
2.5 | 599302 | LOW PRESSURE LINE HOOP |
2.6 | 50280035 | TWO STAGE PRESSURE REDUCER |
2.7 | 519387 | PROTECTIVE COVER |
2.8 | 240801 | CABLE CLIP |
3 | FOOT BRACKET ASSEMBLY | |
3.1 | 90023 | LOCK NUT M6 |
3.2 | 91343 | BOLT M8X16 |
3.3 | 525314-116 | FOOT BRACKET ASSEMBLY |
3.4 | 531115 | FOOT SUPPORT SHOCK MOUNT |
3.5 | 91333 | BOLT M6X28 |
4 | ENGINE ASSEMBLY | |
4.1 | 1148274 210026 | ENGINE |
4.2 | 91322 | BOLT M5X12 |
4.3 | 539602 | CRANKCASE COVER |
5 | HANDLE ASSEMBLY | |
5.1 | 527613 | PLUG |
5.2 | 527611 | BOLT |
5.3 | 526639-116 | HANDLE |
5.4 | 528609 | HANDLE SLEEVE |
6 | CARBON CANNISTER ASSEMBLY | |
6.1 | 95021 | CARBON CANISTER AND AIR FILTER CONNECTING PIPE |
6.2 | 91327 | BOLT M6X12 |
6.3 | 94402 | FUEL LINE CLAMP |
6.4 | 94408 | FUEL LINE CLAMP |
6.5 | 543601L | CANISTER ASSEMBLY |
6.6 | 95020 | CARBON CANISTER AND FUEL TANK CONNECTING PIPE |
6.7 | 94423 | FUEL LINE CLAMP |
7 | DUAL FUEL SELECTOR SWITCH | |
7.1 | 599037 | UPPER COVER |
7.2 | 599038 | LOWER COVER |
7.3 | 599039 | DRIVE SHAFT |
7.4 | 599040 | DRIVE GEAR |
7.5 | 529804 | RESET SPRING |
7.6 | 599054 | FUEL VALVE |
7.7 | 260805 | LOCK CLIP |
7.8 | 90034 | NUT M4 |
7.9 | 92007 | SCREW M4*8 |
7.10 | 599622 | CABLE |
8 | WHEEL ASSEMBLY | |
8.1 | 94224 | FLAT WASHER |
8.2 | 523311 | WHEEL |
8.3 | 524320 | AXLE |
8.4 | 548302 | COTTER PIN |
9 | FUEL TANK ASSEMBLY | |
9.1 | 700277L- 116 | FUEL TANK |
9.2 | 6794 | FUEL GAUGE |
9.3 | 91307 | BOLT M6X25 |
9.4 | 96801 | FUEL TANK GASKET |
9.5 | 94403 | FUEL LINE CLIP |
9.6 | 518207 | FUEL SWITCH |
10 | MUFFLER ASSEMBLY | |
10.1 | 90011 | NUT M8 |
10.2 | 520308 | MUFFLER BRACKET |
10.3 | 91343 | BOLT M8X16 |
10.4 | 96252 | EXHAUST GASKET |
10.5 | 94206 | SPRING WASHER |
10.6 | 705658 | MUFFLER ASSEMBLY |
11 | ALTERNATOR ASSEMBLY | |
11.1 | 755066 | ROTOR STATOR ASSEMBLY |
11.2 | 599019 | CARBON BRUSH |
11.3 | 6560 | TERMINAL ASSEMBLY |
11.4 | 532306 | REAR BEARING CARRIER |
11.5 | 96813 | GASKET |
11.6 | 91721 | BOLT M10 |
11.7 | 91619 | BOLT M6X140 |
11.8 | 91322 | BOLT M5X12 |
11.9 | 534301 | VOLTAGE REGULATOR |
11.10 | 533302-221 | ALTERNATOR COVER |
11.11 | 544604 | SHORT CIRCUITING CONNECTION |
11.12 | 91513 | BOLT M5X175 |
11.13 | 90009 | NUT M5 |
11.14 | 532303-052 | TAIL BRACKET FIXING PLATE |
11.15 | 94204 | SPRING WASHER |
11.16 | 91323 | M5X16 |
12 | CONTROL PANEL ASSEMBLY | |
12.1 | 91327 | BOLT M6X12 |
12.2 | 714361 | PANEL ASSEMBLY |
12.3 | 6501 | IGNITION SWITCH |
12.4 | 6508 | VOLTAGE SELECTION SWITCH |
12.5 | 6041 | DATA CENTER |
12.6 | 6386 | GROUND BOLT ASSEMBLY |
12.7 | 6385 | L14-30R RECEPTACLE |
12.8 | 6848 | WATERPROOF CAP |
12.9 | 6441-22 | 22A THERMAL PROTECTOR |
12.10 | 6015 | RV SOCKET |
12.11 | 6849 | WATERPROOF CAP |
12.12 | 6441-30 | 22A THERMAL PROTECTOR |
12.13 | 6441-20 | 22A THERMAL PROTECTOR |
12.14 | 6032 | L5-20R RECEPTACLE |
12.15 | 6846 | WATERPROOF CAP |
12.16 | 599035 | ROTATING SWITCH |
12.17 | 96120 | WASHER |
12.18 | 92083 | SCREW M6*12 |
13 | 6790 | SPARK ARRESTER |
14 | 518801 | FUEL TANK FILTER |
15 | 519215 | FUEL CAP |
16 | 545331 | TWO STAGE PRESSURE REDUCING |
17 | 99010 | SPARK PLUG WRENCH |
18 | 500942 | FUNNEL |
19 | 99025 | WRENCH 10 & 13 MM ENDS |
20 | 94432 | NYLON BRAIDED TUBE |
21 | 99616 | OIL BOTTLE |
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer service at 855-944-3571.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Westinghouse WGen5300DFv - Dual Fuel Portable Generator Manual
Advertisement
Need help?
Do you have a question about the WGen5300DFv and is the answer not in the manual?
Questions and answers