Westinghouse WGen5300DFv - Dual Fuel Portable Generator Manual

Westinghouse WGen5300DFv - Dual Fuel Portable Generator Manual

Also See for WGen5300DFv:

Advertisement

Westinghouse WGen5300DFv - Dual Fuel Portable Generator Manual

INTRODUCTION


Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www.P65warnings.ca.gov.

DISCLAIMERS

All information, illustrations, and specifications in this manual were in effect at the time of publishing. The illustrations used in this manual are intended as representative reference views only. We reserve the right to make any specification or design change without notice.

ALL RIGHTS RESERVED

All rights reserved. No reproduction allowed in any form without written permission from Westinghouse Outdoor Power Equipment, LLC.



Read this manual before using or performing maintenance on this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS

SPECIFICATIONS

Running Watts: 5300 Gas / 4800 Propane
Peak Watts: 6600 Gas / 5800 Propane
Rated Voltage: 120V/240V
Rated frequency: 60 Hz @ 3600 RPM
Phase: Single phase
Total Harmonic Distortion: ≤ 23%
Engine Displacement: 274 cc
Starting Type: Recoil
Fuel Capacity: 4.7 Gallons (18 Liters)
Fuel Type: Unleaded gasoline
87–93 octane*
Oil Capacity: 0.74 Quart (0.7 Liter)
Oil Type: SAE 10W-30
Spark Plug: 97108 (F7TC)
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake Clearance: 0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust Clearance: 0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
AC Grounding System: Neutral bonded to frame
Voltage Regulator: AVR
Alternator Type: Brushed
Maximum Ambient Temperature: 104°F (40°C)
Certifications:
  • EPA
  • CARB

*Ethanol content of 10% or less. DO NOT use E15 or E85.

UPDATES
Scan the following QR code with your smartphone camera to be directed to the link.

NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). If needed, this product can be operated at temperatures ranging from 5°F (15°C)–122°F (50°C) for short periods. If the product is exposed to temperatures outside of this range during storage, it should be brought back within this range before operation. This product must ALWAYS be operated outdoors in a well-ventilated area and far away from doors, windows, and other vents. Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F (6°C) above 60°F (16°C) ambient temperature.

PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to register your Westinghouse generator.
You can register by:

  • Completing and mailing the product registration card included in the carton.
  • Registering your product online at: https://westinghouseoutdoorpower.com/pages/warranty-registration
  • Scan the following QR code with your smartphone camera to be directed to the mobile registration link.
  • Sending the following product information to: Westinghouse Outdoor Power
    Warranty registration
    777 Manor Park Drive Columbus, OH 43228
    For Your Records
    Date of Purchase:
    Model Number:
    Serial Number:
    Place of Purchase:


Keep your purchase receipt for trouble-free warranty coverage.

SAFETY

SAFETY DEFINITIONS

The words DANGER, WARNING, CAUTION, and NOTICE are used throughout this manual to highlight important information. Make sure that the meanings of this safety information is known to all who operate, perform maintenance on, or are near the generator.
warningThis safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Read and abide by the message that follows the safety alerts symbol.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal property, and/or the environment, or cause the equipment to operate improperly.

Note: Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended.

SAFETY SYMBOLS

Follow all safety information contained in this manual and on the generator.

Symbol Description
warning Safety Alert Symbol
Electrocution Hazard
Asphyxiation Hazard
Burn Hazard. DO NOT touch hot surfaces.
shock hazard Electrical Shock Hazard
Fire Hazard
Maintain Safe Distance
Lifting Hazard
Read Manufacturer's Instructions
DO NOT Operate in Wet Conditions
Ground. Consult with electrician to determine grounding requirements before operation.


Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

SAFETY INSTRUCTIONS

CORRECT USAGE
Example location to reduce risk of carbon monoxide poisoning ONLY use outside and downwind, far away from windows, doors and vents. Direct exhaust away from occupied spaces
SAFETY INSTRUCTIONS
INCORRECT USAGE
Do not operate in any of the following locations:
Near any door, window, or vent

  • Garage
  • Basement
  • Crawl Space
  • Living Area
  • Attic
  • Entry Way
  • Porch
  • Mudroom

NOTICE
Install battery-powered carbon monoxide detectors or plug-in carbon monoxide detectors with battery back-up in living areas.

Fire and electrocution hazard. DO NOT connect to a building's electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.

Electrocution hazard. NEVER use the generator in a location that is wet or damp. NEVER expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.

GENERAL SAFETY PRECAUTIONS

  • NEVER use the generator to power medical support equipment.
  • DO NOT operate the generator when you are tired or under the influence of drugs, alcohol, or medication.
  • DO NOT use generator with electrical cords which are worn, frayed, bare, or otherwise damaged.
  • All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be double-insulated.
  • When this generator is used to supply a building wiring system the generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70, National Electrical Code.
  • If you begin to feel sick, dizzy, or weak while using the generator, move to fresh air IMMEDIATELY. See a doctor, as you can have carbon monoxide poisoning.
  • Only use OUTSIDE and far away from windows, doors, and vents as recommended by the US Department of Health and Human Services Centers for Disease Control and Prevention. Your specific home and/or wind conditions may require additional distance.
  • While operating and storing, keep at least five feet of clearance on all sides of the generator, including overhead. Allow the generator to cool a minimum of 30 minutes before storage. Heat created by the muffler and exhaust gases could be hot enough to cause serious burns and/or ignite combustible objects.
  • DO NOT touch the muffler or engine. They are very HOT and will cause severe burns. DO NOT put body parts or any flammable or combustible materials in the direct path of the exhaust.
  • ALWAYS remove any tools or other service equipment used during maintenance away from the generator before operating.
  • Avoid skin contact with engine oil or gasoline. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
  • A transfer switch must be installed by a licensed electrician approved by the authority having jurisdiction. The installation must comply with all applicable laws and electrical codes.

FUEL SAFETY

  • Store fuel in a container approved for gasoline.
  • DO NOT smoke when filling the generator with gasoline.
  • DO NOT allow the generator's gas tank to overflow when filling.
  • Shut down the engine and allow it to cool for two minutes before adding gasoline or oil to the generator.
  • NEVER remove the fuel cap when the generator is running. Shut off the engine and allow the unit to cool at least two minutes. Remove the fuel cap slowly to release pressure, keep fuel from escaping around the cap, and to avoid the heat from the muffler igniting fuel vapors. Tighten the fuel cap securely after refueling.
  • Wipe spilled fuel from the unit.
  • NEVER attempt to burn off spilled fuel.
  • NEVER overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.
  • Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of rag properly. Allow area of spilled fuel to dry before operating the generator.
  • Wear eye protection while refueling.
  • NEVER use gasoline as a cleaning agent.
  • Store any containers containing gasoline or LPG/ propane in a well-ventilated area, away from any combustibles or source of ignition.

GASOLINE AND GASOLINE VAPOR (GAS)

Fire and explosion hazard. Gasoline and LPG/propane are highly explosive and flammable and can cause severe burns or death.

  • In case of a gas fire, DO NOT attempt to extinguish the flame if the fuel tank valve is in the ON position. Introducing an extinguisher to a generator with an open fuel valve could create an explosion hazard.
  • Gas has a distinctive odor, this will help detect potential leaks quickly.
  • Gas vapors can cause a fire if ignited.
  • Gasoline is a skin irritant and needs to be cleaned up immediately if it comes in contact with the skin.

LIQUID PETROLEUM GAS (LPG/PROPANE)

Fire and explosion hazard. NEVER use a gas container, LPG/propane connector hose, LPG/propane tank or any other fuel item that appears to be damaged.

Fire and explosion hazard. Only use approved LPG/ propane tanks with an Overfilling Prevention Device (OPD) valve. ALWAYS keep the tank in a vertical position with the valve on top and placed at ground level on a flat surface. DO NOT allow tanks to be near any heat source. When transporting and storing, turn the propane tank valve to the fully closed position and disconnect the tank. Make sure to ALWAYS cover the generator inlet and tank outlet with protective plastic caps.

  • LPG/Propane is highly flammable and explosive.
  • Flammable gas under pressure can cause a fire or explosion if ignited.
  • LPG/Propane can settle in low places because it is heavier than air.
  • LPG/Propane has a distinctive odor added to help detect potential leaks.
  • ALWAYS keep a LPG/Propane tank in an upright position.
  • When exchanging LPG/propane tanks, be sure the tank valve is the same type.
  • In case of a LPG/propane fire, DO NOT attempt to extinguish unless the fuel supply can be shut off safely.
  • LPG/propane will burn the skin. Prevent skin contact at all times.
  • Keep the propane tank away from the generator exhaust.
  • Large (500–1000 gallon) LPG/propane tanks will require a certified plumber to install the fuel line to the generator and the loose regulator is not used (the regulator that is attached to the fuel tank). The pressure as measured at the regulator mounted to the generator must be 7" to 14" of water column. A certified plumber must ensure that the pressure is correct or install a step down regulator if needed.


Fire and explosion hazard. If there is a strong smell of propane while operating the generator, fully close the LPG/propane tank valve immediately. Once the propane is off, use soapy water to check for leaks on the hose and connections on the tank valve and the generator. DO NOT smoke or light a cigarette or check for leaks using any open flame source such as a match or lighter. If a leak is found, contact a qualified technician to inspect and repair the LPG/propane system before using the generator.

When starting the generator:

  • Make sure that the fuel cap, air filter, spark plug, fuel lines, and exhaust system are properly in place.
  • If you spill any gasoline on the tank, allow it to fully evaporate before operating.
  • Make sure the generator and LPG/propane tank are on a flat surface before operating.
  • If there is a propane odor DO NOT start the unit because there may be a potential leak. NEVER place a LPG/ propane tank near the engine exhaust.

When transporting or servicing the generator:

  • Make sure the LPG/propane tank and LPG/propane hose are not attached to the generator.
  • Disconnect the spark boot to prevent accidental starting.

When storing the generator:

  • Store away from sparks, open flames, pilot lights, heat, and other sources of ignition.
  • DO NOT store gas or a LPG/propane tank near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.

SAFETY LABELS

SAFETY LABELS - Part 1
SAFETY LABELS - Part 2

COMPONENTS

CONTROL PANEL COMPONENTS

 CONTROL PANEL COMPONENTS

  1. Fuel Selector Switch: Used to select gas or propane operation.
  2. Run/Stop Switch: Push to Run position to start or Stop position to shut the generator off.
  3. Voltage Selector Switch: Select 120V or 240V. Turn generator OFF before switching voltage. When operating at 240V only the L14-30R receptacle is operational.
  4. Data Center: Toggle to show voltage, frequency, total hour meter, and run/maintenance timer.
  5. 120/240 Volt AC, 30 Amp NEMA L14-30R Twist Lock Receptacle: Receptacle can supply either 120V or 240V output.
  6. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle: Receptacle can supply a maximum of 30 Amps.
  1. 120 Volt AC, 20 Amp Duplex NEMA 5-20R Receptacles: Receptacles can supply a maximum of 20 Amps.
  2. 20 Amp AC Circuit Breaker: Circuit breaker limits the current that can be delivered through the NEMA 5-20R receptacles to 20 Amps.
  3. 30 Amp AC Circuit Breaker: Circuit breaker limits the current that can be delivered through the TT- 30R receptacle to 30 Amps.
  4. 22-Amp Circuit Breakers: Each circuit breaker limits the current that can be delivered through each 120 Volt leg on L14-30R to 22amps.
  5. Ground Terminal: The ground terminal is used to externally ground the generator.

DATA CENTER
Voltage:

Displays current voltage output.
Frequency (Hz):

Displays power output frequency in Hertz.
Lifetime Hours:

Displays the lifetime run hours.
Run Time/Maintenance:

Displays current run time. Resets to zero when shut down. Maintenance reminder displayed
Maintenance Codes:
P25: Change engine oil
P50: Clean air filter, Change engine oil
P100: Change engine oil, clean air filter, replace fuel filter
DATA CENTER

GENERATOR COMPONENTS

GENERATOR COMPONENTS

ASSEMBLY

CARTON CONTENTS


Weight hazard. ALWAYS have assistance when lifting the generator.

  1. Carefully open the carton.
  2. Remove and save the carton contents.
  3. Remove and discard the packing tray.
  4. Unfold the top of the plastic bag enclosing the generator.
  5. Carefully cut the vertical corners of the carton to access the generator.
  6. Recycle or dispose of the packaging materials properly.

CARTON CONTENTS

  • User manual
  • Quick Start Guide
  • LPG/propane hose with regulator
  • Bottle of SAE 10W-30 oil
  • Oil Funnel
  • Spark plug wrench
  • Wrench
  • Wheel and mounting foot components:
    Item Quantity
    • Mounting foot
    2
    • Flange bolt, M8
    4
    • Wheel
    2
    • Axle pin
    2
    • Washer
    2
    • Cotter pin
    2

If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.

INSTALL FEET AND WHEELS

NOTICE
Assembling the generator will require lifting the unit on one side. Install the mounting feet and wheel before adding fuel or oil.

  1. Place generator on a flat surface.
  2. Tip the generator on a piece of cardboard or other soft material to protect the frame paint and prevent the generator from sliding.
  3. With the included wrench, install the mounting feet to the frame as shown.

  4. Install the wheels as shown.
    Note: The wheels are only intended for hand transport. The wheels are not suitable for towing the generator either on or off-road.
    INSTALL FEET AND WHEELS

INITIAL OIL FILL

NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT
OIL. DO NOT attempt to crank or start engine before it has been properly serviced with recommended oil. Failure to add engine oil before starting will result in serious engine damage.
NOTICE
Use of 2-stroke/cycle oil or other unapproved oil types can cause severe engine damage that is not covered under warranty.

The included, recommended oil type for typical use is 10W-30 engine oil. If running the generator in extreme temperatures, refer to the following chart.
INITIAL OIL FILL - Step 1

  1. On a level surface, remove the oil dipstick.
    INITIAL OIL FILL - Step 2
  2. Using the supplied funnel and oil, add oil into oil filler neck.
    Note: As residual oil from the factory may remain in the engine, add the oil incrementally near the end of the bottle to prevent overfilling the engine. See Engine Oil Level Check in the Maintenance section.
  3. Wipe the oil dipstick clean. Replace the oil dipstick and hand-tighten.

FUEL


Fire and explosion hazard. NEVER use a gasoline container, gasoline tank, propane connector hose, propane tanks, or any other fuel item that is broken, cut, torn or damaged.

Fire and explosion hazard. DO NOT overfill fuel tank. Fill only to the red fill ring located in the in-tank fuel screen filter. Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard.

Fire and explosion hazard. NEVER refuel the generator while the engine is running. ALWAYS turn the engine off and allow the generator to cool for two minutes before refueling.
NOTICE

DO NOT use E15 or E85 fuel in this product. Engine or equipment damage caused by stale fuel or E85 E15 the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty. Only use unleaded gasoline containing up to 10% ethanol.

FUEL REQUIREMENTS

  • CLEAN, FRESH, unleaded gasoline, 87–93 octane.
  • Up to 10% ethanol (gasohol) is acceptable (where available; non-ethanol fuel is recommended).
  • DO NOT use E85 or E15.
  • DO NOT use a gas oil mix.
  • DO NOT modify the engine to run on alternate fuels.
  • DO NOT fuel indoors.
  • DO NOT create a spark or flame while fueling.

USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow the manufacturer's instructions for use.
ALWAYS mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator. Run the generator for five minutes to allow the stabilizer to treat the entire fuel system.

FILLING THE FUEL TANK

  1. Turn the generator OFF and allow to cool for a minimum of two minutes before fueling.
  2. Place the generator on level ground in a well-ventilated area.
  3. Clean area around fuel cap and remove the cap slowly.
    NOTICE
    Only fill the tank from an approved gasoline container. Make sure the gasoline container is internally clean and in good condition to prevent fuel system contamination.
  4. Slowly add the recommended fuel. DO NOT overfill. Fill only to the red maximum fill ring on the fuel screen filter visible in the filler neck.
    FILLING THE FUEL TANK
  5. Install the fuel cap.

NOTICE
Fuel can damage paint and plastic. Use caution when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty.
NOTICE
Clean the fuel screen filter of debris before and after each fueling. Remove the fuel screen filter by slightly compressing it while removing it from the fuel tank.

CONNECT A LPG/PROPANE TANK

NOTICE

  • The LPG/propane tank can be of any capacity but the tank must conform to the standard as listed in Fuel Safety section.
  • Propane tanks that use liquid withdrawal system can not be used on these models.
  • Verify the re-qualification date on the tank has not expired.
  • DO NOT use included LPG/propane hose for any other appliances.

NOTICE

  • All new tanks must be purged of air and moisture prior to filling. Used tanks that have not been plugged or kept closed must also be purged. The purging process should be done by a propane supplier (Tanks from an exchange supplier should have been purged and filled properly).
  • ALWAYS position the tank so the connection between the valve and the gas inlet will not cause sharp bends or kinks in the hose.


Explosion hazard. DO NOT start generator if you smell propane. ALWAYS fully close the propane tank valve and disconnect the LPG/propane hose from the generator when not in use.

  1. Turn the generator OFF and place on a flat surface in a well ventilated area.
  2. Verify that the propane tank valve is in the fully closed position.
  3. Remove the cover on the generator propane inlet valve.
  4. Use your fingers to hand thread the LPG/propane hose (included) to the propane inlet on the generator.

    DO NOT use thread seal tape or any other type of sealant to seal the LPG/propane hose connection.
  5. Tighten the LPG/propane hose connector to the generator with a 19 mm or adjustable wrench. DO NOT over-tighten.
    Torque: 5-10 lb-ft.
     CONNECT A LPG/PROPANE TANK
  1. Remove the safety plug or cap from the propane tank valve and attach the other end of the hose to the LPG/ propane connector on the tank. Hand-tighten.
  2. Turn the propane tank valve to the fully open position. Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. If a leak exists at a fitting, turn the propane tank valve to the fully closed position and tighten the fitting. Open the propane tank valve and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting then DO NOT use the generator and contact customer service.


Keep the propane tank valve in the fully closed position unless in use.

OPERATION

GENERATOR LOCATION

Read and understand all safety information before starting the generator.


Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

NEVER operate the generator inside any building, including garages, basements, crawlspaces, sheds, enclosure, or compartment, including the generator compartment of a recreational vehicle.


Electrocution hazard. NEVER use the generator in a location that is wet or damp. NEVER expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution

Fire hazard. Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could block cooling vents or the air intake system. Allow the generator to cool for 30 minutes before transport or storage.

The generator should be on a flat, level surface at all times (Even while not in operation). The generator must have at least 5 ft. (1.5 m) of clearance from all combustible material.
DO NOT operate the generator in the back of a SUV, camper, trailer, truck bed (regular, flat, or otherwise), under stairs, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation.


Asphyxiation hazard. Place the generator in a wellventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning the generator.

GROUNDING


Shock hazard. Failure to properly ground the generator can result in electric shock.
NOTICE
Only use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.

The generator neutral is bonded to the frame. There is a permanent conductor between the generator (stator wire) and the frame. If this generator will be used only with cord and plug equipment connected to the receptacles mounted on the generator, National Electric Code does not require that the unit be grounded. However, other methods of using the generator may require grounding to reduce the risk of shock or electrocution. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.

DISCONNECTING THE BONDED NEUTRAL
The bonded neutral should only be removed under specific circumstances. Consult a qualified electrician to determine if your situation requires disconnecting the bonded neutral.

  1. Remove the alternator cover.
  2. Remove the bonded jumper wire and reinstall the nut.
    DISCONNECTING THE BONDED NEUTRAL - Step 1
  1. Remove the nut securing the neutral ground wire and attach the bonded jumper wire. Reinstall the nut.
    DISCONNECTING THE BONDED NEUTRAL - Step 2
  1. Reinstall the alternator cover.


Apply a new "NEUTRAL UNBONDED" Label over the "NEUTRAL BONDED TO FRAME" label on the front of the control panel.

HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes over 5,000 ft. (1524 m). Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. Operation of the engine at altitudes below 2,000 ft. (762 m) with the high altitude kit is not recommended.

High Altitude Carburetor Kit Part# 518965
High Altitude DF Regulator: Part# 518516

Note: You must purchase both the Dual Fuel Regulator and Carburetor Kit for proper high altitude operation.

VOLTAGE SELECTOR SWITCH
The 120V/240V selector switch, which gives the user the ability to double the amperage in the generator for more demanding applications. The voltage selector switches the dual 120V AC windings of the generator to produce 120V or 240V. If a 240V appliance is connected to the 4-prong L14-30R receptacle, the switch must be in the "240V" position. The 120V only outlets will not output power when the Voltage Selector is in the 240V position.

Only change the Voltage Selector Switch with the generator OFF. DO NOT switch the voltage while the generator is running or powering appliances.

FUEL SELECTOR SWITCH

Position the fuel selector switch on the front control panel to the desired fuel choice.

Turn the fuel selector switch fully upward for gasoline operation.

Turn the fuel selector switch fully downward for propane operation.

BREAK-IN PERIOD

For proper break-in, DO NOT exceed 50% of the rated running watts (2650 watts) during the first five hours of operation. Vary the load occasionally to allow stator windings to heat and cool and help seat the piston rings.

BEFORE STARTING THE GENERATOR

Verify that:

  • The generator is placed in a safe, appropriate location.
  • The generator is on a dry, flat, and level surface.
  • The engine is filled with oil.
  • All loads are disconnected.


Fire and explosion hazard. DO NOT move or tip the generator during operation.

STARTING THE ENGINE: GASOLINE

  1. Verify that fuel is in the gas tank.
  2. Turn the fuel selector switch on the control panel to gasoline operation.
  3. Turn the fuel tank valve to the ON position.

    Note: If cold starting, move the choke lever to the ON position.

  4. Push the Run/Stop switch to the Run position.
  5. Firmly grasp and pull the recoil handle slowly until you feel increased resistance, then pull rapidly.
  6. After starting, allow the engine to run for several seconds then move the Choke lever to the fully OFF position.

STARTING THE ENGINE: PROPANE


Fire and explosion hazard. ALWAYS turn the propane tank valve to the fully closed position if not running the generator on propane.

  1. Make sure the LPG/propane hose is correctly connected to the generator and propane tank.
  2. Turn the fuel selector switch to propane operation.
  3. Fully open the valve on the propane tank.
    Note: If cold starting, move the choke lever to the ON position.

  4. Push the Run/Stop switch to the Run position.
  5. Firmly grasp and pull the recoil handle slowly until you feel increased resistance, then pull rapidly.
  6. After starting, allow the engine to run for several seconds then move the Choke lever to the fully OFF position.

SWITCHING FUEL SOURCES


Fire and explosion hazard. DO NOT add gasoline to the fuel tank or connect the LPG/propane hose to the generator while the generator is in operation. The fuel source can be switched while the engine is running if a propane tank is connected to the generator BEFORE operation.

GASOLINE TO PROPANE

Load capacity is reduced when running on propane. Make sure the generator can supply enough (running) and surge (starting) watts for the items you are powering before switching to propane.

  1. Fully open the valve on the propane tank.
  2. Turn the fuel selector switch to propane operation.
  3. Turn the fuel tank valve to the OFF position.

PROPANE TO GASOLINE

  1. Turn the fuel tank valve to the ON position.
  2. Turn the fuel selector switch to gasoline operation.
  3. Turn the propane tank valve to the fully closed position.
    Note: When switching to propane operation the engine may run rough for a few seconds while it purges gasoline in the carburetor.

If the engine stops when switching fuel sources, disconnect all loads then restart the unit on the fuel source of choice.

STOPPING THE ENGINE

  1. Turn off and unplug all connected electrical loads.

    NEVER start or stop the generator with electrical devices connected.
  2. Let the generator run with no load for several minutes to stabilize internal temperatures of the engine.
  3. Push the Run/Stop switch to the Stop position.
    Note: Alternately, if the generator is used infrequently, turn the fuel tank valve to the OFF position to limit the residual fuel remaining in the carburetor float bowl. The engine will stop when fuel in the carburetor and fuel line is exhausted.
  4. If operating on propane, turn the propane tank valve to the fully closed position.

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent basis (more than one month before next use), refer to the Storage section of this manual for information regarding fuel deterioration.

AC CIRCUIT BREAKERS

The circuit breakers will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. If an AC circuit breaker switches OFF automatically, check that the appliance is working correctly and it does not exceed the rated load capacity of the circuit before resetting the AC circuit breaker ON.

GENERATOR CAPACITY

NOTICE
DO NOT overload the generator's capacity. Exceeding the generator's wattage/amperage capacity can damage the generator and/or electrical devices connected to it.

Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the same time. The total power requirements (Volts x Amps = Watts) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model or serial number. To determine power requirements:

  1. Select the items you will power at the same time.
  2. Total the continuous (running) watts of these items. This is the amount of power the generator must produce to keep the items running. See the wattage reference chart.
  3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
    Example:
    Tool or Appliance Running Watts* Starting Watts*
    RV Air Conditioner (11,000 BTU) 1010 1600
    TV (Tube Type) 300 0
    RV Refrigerator 180 600
    Radio 200 0
    Light (75 Watts) 300 0
    Coffee Maker 600 0
    2590 Total Running Watts* 1600
    Highest
    Starting
    Watts*
    Total Running Watts 2590
    Highest Starting Watts + 1600
    Total Starting Watts Needed 4190

    *Wattages listed are approximate. Verify actual wattage.

POWER MANAGEMENT

To prolong the life of the generator and attached devices, use care when adding electrical loads to the generator. There should be nothing connected to the generator outlets before starting the engine. The correct and safe way to manage generator power is to sequentially add loads as follows:

  1. With nothing connected to the generator, start the engine as described in this manual.
  2. Plug in and turn on the first load, preferably the largest load you have.
  3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
  4. Plug in and turn on the next load.
  5. Again, permit the generator to stabilize.
  6. Repeat steps 4 and 5 for each additional load.
    Wattage Reference
    Tool or Appliance Estimated Running Watts* Estimated Starting Watts*
    Incandescent Lights (4 Quantity x 75 Watts) 300 0
    TV (Tube Type) 300 0
    Sump Pump (1/3 hp) 800 1300
    Refrigerator or Freezer 700 2200
    Well Pump (1/3 hp) 1000 2000
    Furnace (1/2 hp) 800 2350
    Radio 200 0
    Drill (3/8", 4 amps) 440 600
    Circular Saw (Heavy Duty, 7-1/4") 1400 2300
    Miter Saw (10") 1800 1800
    Table Saw (10") 2000 2000

    *Wattages listed are approximate. Verify actual wattage.

EXTENSION CORDS


Asphyxiation hazard. Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings. If an extension cord running directly into your home is used to power indoor items, there is a risk of carbon monoxide poisoning to people inside the home. ALWAYS use battery-powered carbon monoxide detector (s) that meet current UL 2034 safety standards when running the generator. Regularly check the detector (s) battery.


Asphyxiation hazard. When operating the generator with extension cords, make sure the generator is located in an open, outdoor area, far away from occupied spaces with exhaust pointed away.

Fire and electrocution hazard. NEVER use worn or damaged extension cords. Damaged or overloaded extension cords could overheat, arc, and burn resulting in death or serious injury.

Before connecting an AC appliance or power cord to the generator:

  • Use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.
  • Make sure the tool or appliance is in good working order. Faulty appliances or power cords can create a potential for electric shock.
  • Make sure the electrical rating of the tool or appliance does not exceed the rated power of the generator or the receptacle being used.

EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for outdoor use that are rated for the electrical load.

Total Minimum Gauge, Outdoor Rated
Amperage Up to 50 FT (15 M) Up to 100 FT (30 M)
Up to 10A
Up to 15A
Up to 20A
Up to 30A
Up to 35A

TRANSPORTING


Weight hazard. ALWAYS have assistance when lifting the generator.

  • Allow the generator to cool a minimum of 30 minutes before transporting.
  • If operating on propane, turn the propane tank valve to the fully closed position.
  • Disconnect the LPG/propane hose from the generator and propane tank.
  • Replace all protective covers on the generator control panel.
  • Only use the generator's fixed frame to lift the unit or attach any load restraints such as ropes or tie-down straps. DO NOT attempt to lift or secure the generator by holding onto any of its other components.
  • Keep the unit level during transport to minimize the possibility of fuel leakage or, if possible, drain the fuel or run the engine until the fuel tank is empty before transport.


Fire hazard. DO NOT up-end the generator or place it on its side. Fuel or oil can leak and damage to the generator may occur.

MAINTENANCE


Accidental start-up. Disconnect the spark plug boot from the spark plug when performing maintenance on the generator.

MAINTENANCE SCHEDULE

Regular maintenance will improve performance and extend the service life of the generator. Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions as noted below.

Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil1
Clean air filter2
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor Inspect/clean spark plug Fuel valve maintenance
Inspect/adjust valve clearance3
After 300 Hours or Every Year
Replace spark plug
Replace air filter

1 Change oil every month when operating under heavy load or in high temperatures.
2 Clean more often under dirty or dusty conditions.
Replace air filter if it cannot be adequately cleaned.
3 Recommend service to be performed by authorized Westinghouse service dealer.

MAINTENANCE REMINDERS

Maintenance reminder codes will be shown on the Data Display based on unit Lifetime Hours. The maintenance codes will be displayed until the unit is turned off. Refer to the Maintenance section for specific procedures.

Maintenance Code Required Maintenance
P25 Change engine oil
P50 Change engine oil, clean air filter
P100
  • Inspect/clean spark arrestor
  • Inspect/clean spark plug
  • Fuel valve maintenance
  • Inspect/adjust valve clearance

MAINTENANCE REPLACEMENT PARTS

Description Part Number
Air filter 5941
Oil drain plug crush washer 94007
Spark arrestor 6790
Spark plug 97108 (F7TC)

AIR FILTER MAINTENANCE

The air filter must be cleaned after every 50 hours of use or six months (frequency should be increased if the generator is operated in a dusty environment).

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. Release the clips and remove the air filter cover.

  3. Clean the air filter with compressed air. Replace if damaged.
  4. Make sure the air filter and rubber cap are correctly installed. Install the air filter cover and secure it in place with the cover clips.
    AIR FILTER MAINTENANCE

ENGINE OIL LEVEL CHECK


Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
NOTICE
ALWAYS use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.

When using the generator under dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions.
ENGINE OIL LEVEL CHECK - PART 1
Check the engine oil level before each use or every 8 hours of operation.

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. With a damp rag, clean around the oil dipstick.
  1. Remove the oil dipstick and wipe the dipstick clean.
    ENGINE OIL LEVEL CHECK - PART 2
  1. Insert the dipstick into the oil filler neck without screwing it in. Remove the dipstick and verify that the oil level is within safe operating range between the low (L) and high (H) marks on the dipstick.

  2. If low, add recommended engine oil incrementally and recheck until the level is between the L and H marks on the dipstick. DO NOT overfill. If over the H mark on the dipstick, drain the oil to reduce the oil level to the full mark.
  3. Replace the oil dipstick and hand-tighten.

ENGINE OIL CHANGE

When using the generator under dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Change the oil while the engine is still warm from operation.

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. With a damp rag, clean around the oil dipstick. Remove the dipstick and wipe clean.
  3. Place an oil pan (or suitable container) under the oil drain bolt.
  4. Using a 10mm wrench, remove the oil drain bolt and allow the oil the to drain.
    ENGINE OIL CHANGE
  5. Install the oil drain bolt and tighten securely.
    Note: A new oil drain plug crush washer is recommended at each oil change.
  6. Slowly pour oil into the oil filler neck until oil the level is between the L and H marks on the dipstick. Stop frequently to check the oil level. DO NOT overfill.
    Maximum oil capacity: 0.74 Quart (0.7 Liter)
  1. Install the oil dipstick and hand-tighten.

NOTICE
DO NOT pollute. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.

SPARK PLUG MAINTENANCE

Inspect and clean the spark plug after every 100 hours of use or six months. Replace the spark plug after 300 hours of use or every year.

  1. Place the generator on a level surface and allow the engine to cool.
  2. Remove the spark plug boot by firmly pulling the spark boot directly away from the engine.

  3. Clean the area around the spark plug.
  4. Remove the spark plug with the included spark plug socket wrench.
    NOTICE
    NEVER apply any side load or move the spark plug laterally when removing the spark plug.
  1. Inspect the spark plug. Replace if electrodes are pitted, burned, or the insulator is cracked. Only use a recommended replacement plug.
  2. Measure the spark plug electrode gap with a wire-type feeler gauge. If necessary, correct the gap by carefully bending the side electrode.
    Spark plug gap: 0.024 – 0.032 in. (0.60 – 0.80 mm)
    SPARK PLUG MAINTENANCE
  3. Carefully install the spark plug finger tight, then tighten as additional 3/8 to 1/2 turn with the spark plug wrench.
  1. Attach the spark plug boot.

SPARK ARRESTOR SERVICE

Allow the muffler to cool completely before servicing the spark arrestor. Check and clean the spark arrestor after every 100 hours of use or six months. Failure to clean the spark arrestor will result in degraded engine performance.

  1. Place the generator on a level surface.
  2. Slide in screwdriver into side slot and remove screw holding clamp (A) on spark arrestor. Pull out spark arrestor assembly.
    SPARK ARRESTOR SERVICE
  3. Carefully remove the carbon deposits from the spark arrestor screen with a wire brush. The spark arrestor must be free of breaks and tears. Replace the spark arrestor if damaged.
  4. Reinstall the spark arrestor.

STORAGE

Proper storage preparation is required for trouble-free operation and generator longevity.

NOTICE
Gasoline stored for as little as 30 days can deteriorate, causing gum, varnish, and corrosive buildup in fuel lines, fuel passages, and the engine. This corrosive buildup restricts the flow of fuel, which can prevent the engine from starting after a prolonged storage period. The use of fuel stabilizer significantly increases the storage life of gasoline. Full-time use of fuel stabilizer is recommended. Follow the manufacturer's instructions for use.

STORAGE TIME RECOMMENDED PROCEDURE
Less than 1 month No service required.
2 to 6 months Fill with fresh gasoline and add gasoline stabilizer.
Drain the carburetor float bowl.
6 months or longer Drain the fuel tank and carburetor float bowl.

SHORT TERM STORAGE

  • Allow the generator to cool a minimum of 30 minutes before storage.
  • If operating on propane, turn the propane tank valve to the fully closed position and disconnect the LPG/ propane hose from the generator and propane tank.
  • Replace all protective covers on the generator control panel.
  • Wipe the generator with a moist cloth. Clean any debris from the muffler cooling vents.
  • Store the generator in a well-ventilated, dry location away from sparks, open flames, pilot lights, heat, and other sources of ignition such as areas with a sparkproducing electric motor or where power tools are operated.
  • DO NOT store the generator, gasoline, or propane tanks near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
  • With the engine and exhaust system cool and all surfaces dry, cover the generator to keep out dust. DO NOT use a plastic sheet as a dust cover. Non-porous materials trap moisture and promote rust and corrosion.

LONG TERM STORAGE
Even properly stabilized fuel can leave residue and cause corrosion if left long term. If storing the generator for two to six months, drain the float bowl to prevent gum and varnish buildup in the carburetor.

DRAINING THE FLOAT BOWL

  1. Turn the fuel tank valve to the OFF position.
  2. Locate the drain screw on the bottom of the carburetor float bowl.
    DRAINING THE FLOAT BOWL
  3. Place an appropriate gasoline container under the drain screw to catch the drained fuel.
  4. Loosen the float bowl drain screw and allow the fuel to drain. Tighten the float bowl drain screw.

DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain the fuel tank to prevent fuel separation, deterioration, and deposits in the fuel system.

  1. Unscrew the fuel tank cap. Remove the fuel screen filter by slightly compressing it while removing it from the tank.
  2. Using a commercially available gasoline hand pump (not included), siphon the gasoline from the fuel tank into an approved gasoline container. DO NOT use an electric pump.
  3. Reinstall the fuel screen filter and the fuel tank cap.
  4. Start the generator and allow it to run until the generator engine stops.
  5. Push the Run/Stop switch to the Stop position.
  6. Remove the spark plug.
  7. Put a teaspoon of engine oil into the cylinder and pull the recoil handle until resistance is felt. At this position the piston is coming up on its compression stroke and both valves are closed. Storing the engine in this position will help prevent internal corrosion. Return the recoil handle gently.
  8. Reinstall the spark plug. Leave the spark plug boot disconnected to prevent accidental starting.

FUEL VALVE MAINTENANCE

The fuel valve is equipped with an inline fuel filter. The fuel valve filter does not require servicing if the unit is properly maintained with fresh, clean fuel. If fuelrelated troubleshooting is required, perform fuel valve maintenance.

  1. Allow the generator to cool completely.
  2. Place an appropriate gasoline container under the carburetor drain bolt to catch the drained fuel.
  3. Remove the drain bolt on the bottom of the carburetor and allow the fuel tank to drain completely. Install and tighten the drain bolt securely.
  4. Remove the fuel line from the fuel valve. Be prepared to capture the remaining fuel from the fuel line.
    FUEL VALVE MAINTENANCE
  5. Loosen the retaining bolt. Unscrew and remove the fuel valve from the fuel tank. Be prepared to capture any remaining fuel from the fuel tank.
  6. Open the fuel valve. Use compressed air to clean the fuel filter and the fuel passage from the fuel line side of the passage.
  7. Install and tighten the fuel valve until it has a few threads remaining and is facing outward.
  8. Hold it in place and tighten the retaining bolt. DO NOT overtighten.
  9. Replace the fuel line and secure with the clamp.

VALVE CLEARANCE

NOTICE
Checking and adjusting valve clearance must be done when the engine is cold.

  1. Remove the rocker arm cover and carefully remove the gasket. If the gasket is torn or damaged, it must be replaced.
  2. Remove the spark plug so the engine can be rotated more easily.
  3. Rotate the engine to top dead center (TDC) by pulling the recoil handle slowly. Looking through the spark plug hole, the piston should be at the top (both valves are closed).
  4. Both the rocker arms should be loose at TDC on the compression stroke. If they are not, rotate the engine 360°.
  5. Insert a feeler gauge between the rocker arm and the valve stem to measure valve clearance.
    VALVE CLEARANCE
    Intake Valve Exhaust Valve
    Valve Clearance 0.0031 – 0.0047 in
    (0.08 – 0.12 mm)
    0.0051 – 0.0067 in
    (0.13 – 0.17 mm)
    Torque 8-12 N•m 8-12 N•m
  6. If an adjustment is necessary, hold the rocker arm pivot and loosen the pivot adjusting nut.
  7. Turn the rocker arm pivot to obtain the specified clearance. Hold the rocker arm pivot and re-tighten the pivot adjusting nut to the specified torque.
    Torque: 106 inch-pound (12 N•m)
  8. Perform this procedure for the other valve.
  9. Install the gasket, rocker arm cover, and spark plug.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTION

Engine will not start

Out of fuel. Refuel.
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Drain the fuel tank. Refuel with fresh gasoline.
Dirty air filter. Clean the air filter.
Low engine oil level stopped generator. Check engine oil level. Add engine oil if low.
Spark plug wet with fuel (flooded engine). Wait five minutes. Turn Run/Stop switch to the OFF position. Pull recoil handle rapidly several times. If the generator does not start, remove spark plug and dry.
Spark plug faulty, fouled, or improperly gapped. Gap or replace the spark plug. Reinstall.
Fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Contact Westinghouse customer service tollfree at 1 (855) 944-3571.
Choke partially open or closed. Fully open or close the choke.

Engine starts, then shuts down

Out of fuel. Refuel.
Incorrect engine oil level. Check engine oil level.
Dirty air filter. Clean the air filter.
Contaminated fuel. Drain the fuel tank. Refuel with fresh gasoline.
Defective low oil level switch. Contact Westinghouse customer service tollfree at 1 (855) 944-3571.

Engine lacks power

Air filter restricted. Clean or replace air filter.
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Drain the fuel tank. Refuel with fresh gasoline.
Fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Contact Westinghouse customer service tollfree at 1 (855) 944-3571.

Engine runs rough or bogs when load applied

Dirty air filter. Clean the air filter.
Generator overloaded. Unplug some devices.
Faulty power tool or appliance. Replace or repair tool or appliance. Stop and restart the engine.
Fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Contact Westinghouse customer service tollfree at 1 (855) 944-3571.

No power at AC receptacles

AC circuit breaker/s tripped. Check AC loads and reset circuit breaker/s.
Faulty power tool or appliance. Replace or repair tool or appliance. Stop and restart the engine.
Faulty generator. Contact Westinghouse customer service tollfree at 1 (855) 944-3571.

Frost on the propane tank or regulator

If the temperature of the propane tank drops below the dew point, condensation on the tank may turn to frost or ice. This typically occurs in humid conditions. Providing all the propane fuel handling equipment is functioning normally, no correction is needed.
The Propane tank is not equipped with an Overfilling Prevention Device (OPD). If you suspect your propane fuel tank is not equipped with an OPD device, discontinue operation immediately and replace the propane fuel tank with a propane tank equipped with a an OPD.
Propane fuel tank overfilled. If you suspect your propane fuel tank has been overfilled, discontinue operation immediately and return the propane fuel tank to the place of purchase or refilling.

Propane fuel smell

Fuel regulator or fuel hose and fittings not securely sealed. Using a soap solution check each connection and tighten as needed.
Propane fuel regulator vent active. The propane fuel regulator is equipped with a vent that will allow a small amount of propane fuel vapor to escape from the regulator when the propane tank valve is opened. This can be normal providing the venting of the propane is brief. If you suspect that this is abnormal, immediately discontinue use and have the propane regulator inspected by a qualified technician.
Residual fuel from the carburetor dispersing after operation. Normal, no correction is needed.
Poor performance or engine stalling on Propane Propane fuel line kinked or crushed. Inspect propane fuel line and remove kinks or other obstructions.
Fuel selector valve not properly positioned. Rotate the fuel valve fully until the pointer is directly in line with the desired fuel.
Gasoline not purged from the carburetor before switching to propane. Close the propane fuel tank valve. Move the fuel selector switch to gas. Start the engine and allow the engine to run until the gasoline has been consumed in the carburetor. Begin propane start up procedure.

EXPLODED VIEW AND PARTS LIST

EXPLODED VIEW A

EXPLODED VIEW A

EXPLODED VIEW A

NO. PART# DESCRIPTION
1 CRANKCASE ASSEMBLY
1.1 400201 CRANKCASE
1.2 93509 CRANKCASE OIL SEAL
1.3 93520 CRANKCASE OIL SEAL
1.4 403901 GOVERNOR SHAFT
1.5 96804 GOVERNOR SHAFT OIL SEAL
1.6 383902 RETAINING CLIP
1.7 245106 OIL SENSOR ASSEMBLY
1.8 91329 BOLT M6*16
1.9 404301 GOVERNOR GEAR ASSEMBLY
1.10 93012 AXLE BEARING
2 ALTERNATOR ASSEMBLY
2.1 402002 CAMSHAFT ASSEMBLY
2.2 406101 VALVE LIFTER
2.3 401901 PUSH ROD
3 400301 CRANKSHAFT
4 CRANKCASE COVER ASSEMBLY
4.1 93509 CRANKCASE OIL SEAL
4.2 240904 CRANKCASE LOCATING PIN
4.3 96222 CRANKCASE GASKET
4.4 400101 CRANKCASE COVER
4.5 91347 BOLT M8*30 GB/T5787-1986
4.6 245601-295 DIPSTICK
4.7 93012 AXLE BEARING
5 SPEED CONTROL BRACKET ASSEMBLY
5.1 91329 BOLT M6*16
5.2 404001 SPEED REGULATING ARM
5.3 91822 BOLT M6*21
5.4 90016 NUT M6
5.5 402701 THROTTLE LEVER
5.6 404201 SPRING C
5.7 404101 SPRING B
5.8 407701 SPEED CONTROL BRACKET
6 LOWER GUARD ASSEMBLY
6.1 407601 UNDER GUARD
6.2 91325 BOLT M6*12
7 SHROUD ASSEMBLY
7.1 407501 WIND-LEAD-COVER
7.2 91325 BOLT M6*12
8 97108 SPARK PLUG
9 CYLINDER HEAD COVER ASSEMBLY
9.1 91329 BOLT M6*16
9.2 96225 HEADCOVER GASKET
9.3 401102 CYLINDER HEAD INTERNAL COVER
9.4 96226 CYLINDER HEAD INTERNAL COVER GASKET
9.5 401101 CYLINDER HEAD COVER
9.6 92036 SCREW
9.7 95603 BREATHER TUBE
9.8 94435 BREATHER TUBE CLIP
10 CYLINDER HEAD ASSEMBLY
10.1 401002 CYLINDER HEAD
10.2 401701 INTAKE VALVE
10.3 405901 EXHAUST VALVE
10.4 406001 VALVE SPRING
10.5 402101 ROCKER ARM
10.6 91818 BOLT
10.7 402201 VALVE RETAINER ASSEMBLY
10.8 241806 VALVE SEAL
10.9 241817 VALVE SPRING RETAINER
10.10 329930 VALVE LOCK CLAMP
10.11 241804 TOP CAP
10.12 91022 DOUBLE END BOLT M6*95
10.13 91007 DOUBLE END BOLT M8*38
10.14 260901 CYLINDER HEAD LOCATING PIN
10.15 96223 CYLINDER HEAD GASKET
10.16 91452 BOLT M10
10.17 96235 GASKET
10.18 402301 CARBURETOR CONNECTION BLOCK
11 PISTON & PISTON RING ASSEMBLY
11.1 401201 PISTON
11.2 401601 PISTON RING ASSEMBLY
11.3 401501 CONNECTING ROD ASSEMBLY
11.4 405501 PISTON PIN
11.5 241301 PISTON PIN RING
12 CARBURETOR ASSEMBLY
12.1 94403 FUEL LINE CLAMP
12.2 402804-295 CARBURETOR ASSEMBLY
12.3 95727L FUEL LINE
12.4 517917 LOW PRESSURE HOSE
12.5 599302 FUEL LINE CLAMP
13 AIR CLEANER ASSEMBLY
13.1 91329 BOLT M6
13.2 90016 NUT M6
13.3 402901 AIR CLEANER ASSEMBLY
14 IGNITOR ASSEMBLY
14.1 97552 IGNITER
14.2 91331 BOLT M6
15 FLYWHEEL ASSEMBLY
15.1 244508 STARTER PULLEY
15.2 240401 FLYWHEEL ASSEMBLY
15.3 404601 IMPELLER
15.4 90003 NUT
16 RECOIL STARTER ASSEMBLY
16.1 91325 BOLT M6
16.2 404706-221A STARTER ASSEMBLY
16.3 5943 RECOIL HANDLE
16.4 5942-221 RECOIL STARTER ASSEMBLY
16.5 240801 CABLE CLIP
17 91816 BOLT M10*1.25*15
18 94007 OIL DRAIN BOLT WASHER
19 96224 CARBURATOR GASKET
20 94324 STEEL WASHER
21 5941 AIR FILTER ELEMENT

EXPLODED VIEW B

EXPLODED VIEW B

EXPLODED VIEW B

NO. PART# DESCRIPTION
1 FRAME ASSEMBLY
1.1 774058-116 FRAME
1.2 531318 DAMPING BEARING
1.3 90016 NUT M6
1.4 90018 NUT M8
1.5 91325 BOLT M6X12
1.6 91327 BOLT M6X12
1.7 544301 GROUND WIRE
1.8 96120 WASHER
1.9 530324-116 FUEL TANK BRACKET
1.10 94002 TOOTH WASHER
2 PRESSURE REDUCING VALVE ASSEMBLY
2.1 91325 BOLT M6X12
2.2 91327 BOLT M6X12
2.3 96120 GASKET
2.4 517336 LOW PRESSURE LINE
2.5 599302 LOW PRESSURE LINE HOOP
2.6 50280035 TWO STAGE PRESSURE REDUCER
2.7 519387 PROTECTIVE COVER
2.8 240801 CABLE CLIP
3 FOOT BRACKET ASSEMBLY
3.1 90023 LOCK NUT M6
3.2 91343 BOLT M8X16
3.3 525314-116 FOOT BRACKET ASSEMBLY
3.4 531115 FOOT SUPPORT SHOCK MOUNT
3.5 91333 BOLT M6X28
4 ENGINE ASSEMBLY
4.1 1148274 210026 ENGINE
4.2 91322 BOLT M5X12
4.3 539602 CRANKCASE COVER
5 HANDLE ASSEMBLY
5.1 527613 PLUG
5.2 527611 BOLT
5.3 526639-116 HANDLE
5.4 528609 HANDLE SLEEVE
6 CARBON CANNISTER ASSEMBLY
6.1 95021 CARBON CANISTER AND AIR FILTER CONNECTING PIPE
6.2 91327 BOLT M6X12
6.3 94402 FUEL LINE CLAMP
6.4 94408 FUEL LINE CLAMP
6.5 543601L CANISTER ASSEMBLY
6.6 95020 CARBON CANISTER AND FUEL TANK CONNECTING PIPE
6.7 94423 FUEL LINE CLAMP
7 DUAL FUEL SELECTOR SWITCH
7.1 599037 UPPER COVER
7.2 599038 LOWER COVER
7.3 599039 DRIVE SHAFT
7.4 599040 DRIVE GEAR
7.5 529804 RESET SPRING
7.6 599054 FUEL VALVE
7.7 260805 LOCK CLIP
7.8 90034 NUT M4
7.9 92007 SCREW M4*8
7.10 599622 CABLE
8 WHEEL ASSEMBLY
8.1 94224 FLAT WASHER
8.2 523311 WHEEL
8.3 524320 AXLE
8.4 548302 COTTER PIN
9 FUEL TANK ASSEMBLY
9.1 700277L- 116 FUEL TANK
9.2 6794 FUEL GAUGE
9.3 91307 BOLT M6X25
9.4 96801 FUEL TANK GASKET
9.5 94403 FUEL LINE CLIP
9.6 518207 FUEL SWITCH
10 MUFFLER ASSEMBLY
10.1 90011 NUT M8
10.2 520308 MUFFLER BRACKET
10.3 91343 BOLT M8X16
10.4 96252 EXHAUST GASKET
10.5 94206 SPRING WASHER
10.6 705658 MUFFLER ASSEMBLY
11 ALTERNATOR ASSEMBLY
11.1 755066 ROTOR STATOR ASSEMBLY
11.2 599019 CARBON BRUSH
11.3 6560 TERMINAL ASSEMBLY
11.4 532306 REAR BEARING CARRIER
11.5 96813 GASKET
11.6 91721 BOLT M10
11.7 91619 BOLT M6X140
11.8 91322 BOLT M5X12
11.9 534301 VOLTAGE REGULATOR
11.10 533302-221 ALTERNATOR COVER
11.11 544604 SHORT CIRCUITING CONNECTION
11.12 91513 BOLT M5X175
11.13 90009 NUT M5
11.14 532303-052 TAIL BRACKET FIXING PLATE
11.15 94204 SPRING WASHER
11.16 91323 M5X16
12 CONTROL PANEL ASSEMBLY
12.1 91327 BOLT M6X12
12.2 714361 PANEL ASSEMBLY
12.3 6501 IGNITION SWITCH
12.4 6508 VOLTAGE SELECTION SWITCH
12.5 6041 DATA CENTER
12.6 6386 GROUND BOLT ASSEMBLY
12.7 6385 L14-30R RECEPTACLE
12.8 6848 WATERPROOF CAP
12.9 6441-22 22A THERMAL PROTECTOR
12.10 6015 RV SOCKET
12.11 6849 WATERPROOF CAP
12.12 6441-30 22A THERMAL PROTECTOR
12.13 6441-20 22A THERMAL PROTECTOR
12.14 6032 L5-20R RECEPTACLE
12.15 6846 WATERPROOF CAP
12.16 599035 ROTATING SWITCH
12.17 96120 WASHER
12.18 92083 SCREW M6*12
13 6790 SPARK ARRESTER
14 518801 FUEL TANK FILTER
15 519215 FUEL CAP
16 545331 TWO STAGE PRESSURE REDUCING
17 99010 SPARK PLUG WRENCH
18 500942 FUNNEL
19 99025 WRENCH 10 & 13 MM ENDS
20 94432 NYLON BRAIDED TUBE
21 99616 OIL BOTTLE

SCHEMATICS

SCHEMATICS

DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer service at 855-944-3571.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Westinghouse WGen5300DFv - Dual Fuel Portable Generator Manual

Advertisement

Need help?

Need help?

Do you have a question about the WGen5300DFv and is the answer not in the manual?

Questions and answers

Table of Contents