Mimosa A6 - 5 And 6 GHz Fixed Wireless WiFi 6E PTMP Access Point SetUp Manual

Mimosa A6 - 5 And 6 GHz Fixed Wireless WiFi 6E PTMP Access Point SetUp Manual

Advertisement

Mimosa A6 - 5 And 6 GHz Fixed Wireless WiFi 6E PTMP Access Point SetUp Manual

Introduction



UNLOCK REQUIRED
This device requires unlocking prior to use. For all unlocking instructions and options prior to onsite installation, please visit: mimosa.co/start

For instructions, videos and help visit: support.mimosa.co

Additional Required & Optional Items

  • 10 AWG (5.26 mm2) ground cable with pre-terminated ring terminal
  • Small flat head type screwdriver (for direct 48VDC power terminal)
  • 15, 13 and 10 mm socket or adjustable wrench for mounting assembly
  • Power Option A: 18 AWG 2-pin wire for direct power wiring 48VDC input
  • Power Option B: Shielded CAT6/6A & compatible PoE injector (refer to A6 datasheet specifications)
  • Optional: SFP+ fiber (non-copper) module and preferred optical cabling
  • Optional: 19mm (3/4") flexible conduit/ hose tubing and hose-clamps for additional cable protection

Mounting

Mounting

Tightly attach the supplied sliding & pivot brackets to mounting pole in desired up or downtilt orientation.

Grounding

Grounding
Attach 10 AWG ground wire with pre-terminated ring terminal to the grounding screw.

Dedicated 48VDC Power

Dedicated 48VDC Power

  • Thread an 18 AWG 2-pin cable through one the supplied IP67 gland/cap.
  • Strip the wire jackets approximately 6-7mm, and attach to the supplied power connector terminals (+/- indicated in diagram). Tighten the terminal screws. Note: reverse polarization will not damage the device, however proper +/- wiring is required to apply power.
  • Insert and snap the power plug and cable into the PWR port.
  • Attach and tighten gland, attach the rubber insert to the cable, pushing it into the gland, then tighten the cap.

Gigabit Ethernet or PoE

Gigabit Ethernet or PoE

Insert a shielded CAT6/6A Ethernet cable through the IP67 gland/cap. Connect the cable to ETH port. Attach and tighten gland, attach the rubber insert to the cable, pushing it into the gland, then tighten the cap.
PoE powering is optional and can be used as primary or as redundant/backup power to the 48VDC. Ethernet connection is NOT required if SFP+ optical fiber is being used.

Optional Flexible Conduit

Optional Flexible Conduit

The provided IP67 gland caps are designed to accommodate optional 19mm (3/4") outdoor hose conduit/tubing, and hose-type clamps to secure the tubing. Both can be procured at most hardware stores.

Optional SFP+ Optical Fiber

Two SFP+ ports are provided to accommodate standard SFP+ 10 Gbps optical modules, and bult-in switching between the ports for interconnectivity to other devices.
Visit support for additional SFP+ module and configuration information.

Seal All Unused Ports

For any unused ports, tightly screw in the supplied port sealing caps to maintain environmental integrity of the system.

Unlock and Configure

Visit start.mimosa.co to unlock the device.

Warnings, Warranty, Compliance & Regulatory Statements

Mimosa by Airspan ("Mimosa") products are provided by Airspan Networks Inc. ("Airspan").

Export Control

These commodities, technology, or software were exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Important Safety and Handling Information

Failure to follow any of the safety instructions in this guide, instructions on any Airspan provided packaging, and heed WARNINGS (indicated by warning), could result in fire, electric shock, other injury or death, and incur damage to this product or other property and void the product's Limited Warranty.

There are no End User serviceable parts inside the equipment.

Read all operating and safety instructions contained herein and accompanying the product as provided by Airspan:

Electrical Safety Information

shock hazard

  • Do not operate this product in any location that can be submerged by water.
  • Do not install or maintain this product during the presence of an electrical storm to avoid risk of electric shock from lightning. Failure to ground the device according to the included instructions using shielded CAT6/6A Ethernet cabling could lead to serious injury or death.
  • Installation of the product must comply with local and national electrical codes.
  • Power specifications for connected devices are indicated on the device's own label or documentation. Connecting to any power source that does not meet the voltage, frequency and current requirements listed may damage the power supply or product, and pose a fire hazard.

Mandatory Grounding Instructions


Failure to properly ground the device using the following instructions will violate the limited warranty conditions in this document.

Required Step 1- Direct Grounding on the Device:
A minimum grounding wire of 10 AWG (5.26 mm2) with a secured grounding terminal, and shorter in length than 1 meter is required. It is NOT supplied with the product.

  1. Ensure that NO power is being supplied to the product.
  2. Locate the Ground point screw next to the Ground icon on the device
  3. Remove the provided Ground Screw
  4. Thread the ground wire terminal and ground wire meeting the above specifications over the screw removed in the previous step.
  5. Replace and tighten the screw with the threaded ground terminal and cable at the product Ground point.
  6. Secure the other end of the grounding cable to the properly grounded structure (pole, tower, mast, etc.) meeting local and national electrical regulations and codes.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Mimosa A6 - 5 And 6 GHz Fixed Wireless WiFi 6E PTMP Access Point SetUp Manual