Welding Works; Removing Battery Terminals; Safety First When Using High-Pressure Grease To Adjust Track Tension; Do Not Disassemble Recoil Springs - Komatsu PC750LC-7 Operation Manual

Hide thumbs Also See for PC750LC-7:
Table of Contents

Advertisement

SAFETY

WELDING WORKS

Welding operations must always be carried out by a qualified welder and in a place equipped with proper equipment.
There is a hazard of gas, fire, or electrocution when carrying out welding, so never allow any unqualified personnel
to carry out welding.

REMOVING BATTERY TERMINALS

When repairing the electrical system or when carrying out electrical welding, remove the negative (-) terminal of the
battery to prevent the flow of current.

SAFETY FIRST WHEN USING HIGH-PRESSURE GREASE TO ADJUST TRACK TENSION

Grease is pumped into the track tension adjustment system
under high pressure.
If the specified procedure for maintenance is not followed when
making adjustment, grease drain plug (1) may fly out and cause
serious injury or property damage.
When loosening grease drain plug (1) to loosen the track
tension, never loosen it more than one turn. Loosen the grease
drain plug slowly.
Never put your face, hands, feet, or any other part of your body
close to grease drain plug (1).

DO NOT DISASSEMBLE RECOIL SPRINGS

Never attempt to disassemble the recoils spring assembly. It contains a spring under high pressure which serves
as a shock absorber for the idler. If it is disassembled by mistake, the spring will fly out and cause serious injury.
When it becomes necessary to disassemble it, ask your Komatsu distributor to do the work.

SAFETY RULES FOR HIGH-PRESSURE OIL

The hydraulic system is always under internal pressure. When inspecting or replacing piping or hoses, always
check that the pressure in the hydraulic circuit has been released. If the circuit is still under pressure, it will lead to
serious personal injury, so always do as follows.
For details of the method of releasing the pressure, see "METHOD FOR RELEASING INTERNAL PRESSURE
IN HYDRAULIC CIRCUIT (PAGE 4-40)". If the circuit is still under pressure, do not carry out any inspection or
replacement operation.
If there is any leakage from the piping or hoses, the surrounding area will be wet, so check for cracks in the piping
and hoses and for swelling in the hoses.
When carry out inspection, wear safety glasses and leather gloves.
SAFETY MAINTENANCE INFORMATION
2 - 37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc750-7Pc750se-7Pc800-7Pc800se-7

Table of Contents