Safety Precautions Please read these safety precautions before using this machine to ensure correct operation. The cautions shown here tell you how to use this unit safely and prevent harm to you and other people. Furthermore, in order to differentiate between the magnitude and severity of the precautions, the effects that may occur if the product is handled incorrectly are divided into "Warnings"...
Page 21
CAUTION Do not cover the air inlet or Do not expose to naked outlet. flame, such as cigarettes. Do not clean with petrol or Do not use in the vicinity of thinner or apply insecticide. flammable or corrosive gases or metal dust. Do not operate in the vicinity Do not use in wet places of smoke-producing...
Page 22
CAUTION Do not expose to oily Do not use in an unstable vapours. position where unit may tilt or fall over. The machine must not be If the power cable is allowed to ingest humidifier damaged, it must be replaced steam.
Page 23
Parts and Terms ■Front ■Back Main Unit Remote control Operation panel Sensor sensibility switch Safety switch Air outlet Gas sensor Remote Cleanness level lamp control holder UV light Front Cover Filter Photocatalyst filter Dust sensor Cord holder Power cord Belt Plug Base 3-in-1 filter...
Preparation Before Using Before using be sure to remove the 3-in-1 filter from its bag ※ Unplug the unit before installing the filter 1. Removing the 3-in-1 filter *Place the unit in a stable location. 1. To remove front coverDepress the finger pieces at bottom of cover to release it, then pull to remove.
Page 25
Installing remote control battery Remove the transparent sheet protecting battery power. The battery is pre-installed in the remote control. Transparent sheet Replacing battery 1. Remove battery holder from back of remote. 2. Insert new battery correct side up. 3. Replace cover. Battery + pole must align with mark on holder About the battery...
Installation Can be put on the floor or the desk. Do not use the remote control in the following places Rooms exposed to Rooms with fluorescent light, especially inverter typeThis direct sunlight.This may cause remote may cause remote failure. Keep away failure.
Page 27
Panel and operation Cleanness light Smells and dirt are shown in 3 levels Power/mode key Green Green Clean To turn on and off, select operating mode and change airflow. Green Dirty uality Remote control receiver Negative ion light Gas sensor Illuminates in ion generation mode.
Page 28
To Operate Following stable installation, insert the mains plug. Operation by the main unit uality Press the power/mode key for automatic operation. Sensors take about 30 seconds to start working. Press the key again to change operation as follows: Anti Allergy(AA) Turbo Stop mode: sets airflow according to air quality.
Page 29
Operation with remote control ON key .Press to start automatic mode. .When first switching on, you will find the cleanness level light flashes for 30 seconds before display appears. .If the main unit is set to manual, press this key to change to automatic. Anti ALLERGY (AA) key ....
Maintenance Cleaning the unit periodically maintains efficient operation. Proper cleaning function is disrupted by accumulation of dirt, so clean frequently. WARNING Unplug before cleaning. Front cover (once a month) 1. Unplug from the mains 2. Clean front cover Clean air inlet with vacuum cleaner. Remove if dirty (see page 5 , 6) and wash in cold water.
Page 31
Dust sensor 2. Carefully use a swab to wipe the shiny 1. Remove sensor cover on right of unit. surface of the lens. 1 Push to release latch 2 Pull in arrow direction 3 Pull forwards Lens 3. Replace sensor cover on unit Sensor may malfunction without cover.
Page 32
3-in-1 filter 3. Clean the pre-filter Remove pre-filter from unit and clean with vacuum cleaner, or wash in cold water. 4. Clean the 3-in-1 filter Clean with vacuum cleaner without removing from unit. CAUTION Do not apply pressure with vacuum cleaner , and do not damage the filter when washing.
Filter Replacement Filter replacement time When the filter is dirty, the light illuminates. Time until illumination depends on air quality. The state of filter is saved even when unit is uality unplugged or moved. Conditions leading to shorter replacement period: Soot or the like is ingested.
Troubleshooting WARNING Do not repair or disassemble without qualified assistance. When this happens check .Is there a power failure (perhaps caused by fuse or circuit The unit does not work breaker)? .Is it plugged in? .Are filter and front cover securely fitted? .Has filter been removed from bag? Unit does not remove smell or smoke...
Page 35
When it happens check When using in a dirty place other than ordinary domestic Cleaning light or situations the light might illuminate early. replacement reminder light Are Turbo and High used frequently? Even if room is clean, illuminates too soon if operated on High or Turbo, light illuminates early Foreign objects have Switch off and seek help from your service agent.
Model: APF003H .AP688 Charcoal Filter please indicate which item you require to Model: APF002C Whirlpool spare parts department. Tel: 24063861/24063862 Correct disposal of this product This symbol indicates this product should not be disposed of with other domestic waste anywhere in the EU. To prevent possible damage to the environment or human health from uncontrolled waste disposal, help by recycling responsibly.