Download Print this page

Whirlpool WHELJ1 Performance Data Sheet

Central water filtration system

Advertisement

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water supply tested to determine your actual water treatment needs. This filter system is designed to be used for the reduction of the performance claim
listed below. Do not use where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. While testing was performed under standard
laboratory conditions, actual performance of the system may vary based on local water conditions. Some or all of the contaminants reduced by this system may not be in your water supply.
See Installation and Operation Manual for further instructions, system installation, operating procedures, and warranty. This system works on 24 volt-60 Hz electrical power only.
The maintenance instructions must be followed for the product to perform as indicated below.
Contaminant
Chlorine
1
mg/L means Milligrams Per Liter, which is equivalent to parts per million (ppm).
2
NSF minimum percent reduction requirement. Acceptance level for this substance is based on percent reduction rather than maximum effluent concentration.
GENERAL INFORMATION
This filter improves the taste and odor in drinking water. This system has been tested according
to NSF/ANSI 42 for the reduction of the substance listed above. The concentration of the
indicated substance in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42. The
testing was performed using spiked tap water at a flow rate of 6.0 gpm (22.7 L/min.), pH of
7.23, pressure of 60 psig, and temperature of 68 ± 5°F.
Manufactured and warranted by Ecodyne Water Systems
1890 Woodlane Drive
Woodbury, MN 55125
1-866-986-3223
System tested and certified by the
Water Quality Association against
CSA, B483.1.
IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water supply tested to determine your actual water treatment needs. This filter system is designed to be used for the reduction of the performance claim listed
below. Do not use where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. While testing was performed under standard
laboratory conditions, actual performance of the system may vary based on local water conditions. Some or all of the contaminants reduced by this system may not be in your water supply. See
Installation and Operation Manual for further instructions, system installation, operating procedures, and warranty. This system works on 24 volt-60 Hz electrical power only. The
maintenance instructions must be followed for the product to perform as indicated below.
Require Influent
Contaminant
Level (mg/L)
Chlorine
1
mg/L means Milligrams Per Liter, which is equivalent to parts per million (ppm).
2
NSF minimum percent reduction requirement. Acceptance level for this substance is based on percent reduction rather than maximum effluent concentration.
GENERAL INFORMATION
This filter improves the taste and odor in drinking water. This system has been tested according
to NSF/ANSI 42 for the reduction of the substance listed above. The concentration of the
indicated substance in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42. The
testing was performed using spiked tap water at a flow rate of 6.0 gpm (22.7 L/min.), pH of
7.23, pressure of 60 psig, and temperature of 68 ± 5°F.
Manufactured and warranted by Ecodyne Water Systems
1890 Woodlane Drive
Woodbury, MN 55125
1-866-986-3223
System tested and certified by
the Water Quality Association
against CSA, B483.1.
PERFORMANCE DATA SHEET
Model WHELJ1 Central Water Filtration System
Require Influent
NSF Max. Permissible Eff.
1
Level (mg/L)
Level (mg/L)
2.0 ± 10%
2
50%
System tested and certified by NSF
International NSF/ANSI Standard 42 for
chlorine taste and odor reduction.
PERFORMANCE DATA SHEET
Model WHELJ1 Central Water Filtration System

PERFORMANCE CLAIMS

NSF Max. Permissible Eff.
1
Level (mg/L)
2.0 ± 10%
2
50%
System tested and certified by NSF
International NSF/ANSI Standard 42 for
chlorine taste and odor reduction.
PERFORMANCE CLAIMS
Average Influent
1
1
Level(mg/L)
2.0
Pressure Range......................................................................................... 30-125 psig (2.1-8.8 kg/cm
Pressure Drop at 6.0 gpm....................................................................................... 10 psi (0.70 kg/cm
Temperature Range............................................................................................ 40-120°F (4.4-48.9°C)
Rated Service Flow .....................................................................................................6 gpm (22.7 lpm)
Rated Capacity @ 2.0 ppm chlorine ............................................................................. 570,000 gallons
Rated Capacity @ 1.5 ppm chlorine ........................................................................... 760,000 gallons*
Rated Capacity @ 1.0 ppm chlorine ........................................................................ 1,140,000 gallons*
Rated Capacity @ 0.75 ppm chlorine ...................................................................... 1,520,000 gallons*
Rated Capacity @ 0.5 ppm chlorine ........................................................................ 2,280,000 gallons*
Typical residential chlorine concentration is 0.5-1.0 ppm
* From independent laboratory test data
Refer to Installation and Operation Manual for warranty and further details on installation and
maintenance.
Average Influent
1
1
Level(mg/L)
2.0
Pressure Range......................................................................................... 30-125 psig (2.1-8.8 kg/cm
Pressure Drop at 6.0 gpm....................................................................................... 10 psi (0.70 kg/cm
Temperature Range............................................................................................ 40-120°F (4.4-48.9°C)
Rated Service Flow .....................................................................................................6 gpm (22.7 lpm)
Rated Capacity @ 2.0 ppm chlorine ............................................................................. 570,000 gallons
Rated Capacity @ 1.5 ppm chlorine ........................................................................... 760,000 gallons*
Rated Capacity @ 1.0 ppm chlorine ........................................................................ 1,140,000 gallons*
Rated Capacity @ 0.75 ppm chlorine ...................................................................... 1,520,000 gallons*
Rated Capacity @ 0.5 ppm chlorine ........................................................................ 2,280,000 gallons*
Typical residential chlorine concentration is 0.5-1.0 ppm
* From independent laboratory test data
Refer to Installation and Operation Manual for warranty and further details on installation and
maintenance.
Average Effluent Level
Average
1
(mg/L)
Percent Removal
0.47
82.5
INSTALLATION REQUIREMENTS
MAINTENANCE
Average Effluent Level
Average
1
(mg/L)
Percent Removal
0.47
82.5
TALLATION REQUIREMENTS
MAINTENANCE
2
)
2
)
05/31/11 (Rev. L)
7303182
2
)
2
)
5/31/11 (Rev. L)
7303182

Advertisement

loading