TABLE
UOUTPUTS (cont)
ODF_VFD-A Actual Speed %
ODF_VFD-B Actual Speed %
COOLING
Compressor A1 Relay
Compressor A2 Relay
Compressor A3 Relay
Compressor B1 Relay
Compressor B2 Relay
Compressor B3 Relay
Compressor A1 Capacity
Minimum Load Valve Relay
Humidimizer 3-Way Valve
Condenser EXV Position
Bypass EXV Position
HEATING
Heat Relay 1
Modulating Heat Capacity
Heat Relay 2
Relay 3 W1 Gas Valve 2
Relay 4 W2 Gas Valve 2
Relay 5 W1 Gas Valve 3
Relay 6 W2 Gas Valve 3
Heat Interlock Relay
ACTUATORS
Economizer Act.Curr.Pos.
Economzr 2 Act.Curr.Pos.
Economizer Act.Cmd.Pos.
Economzr 2 Act.Curr.Pos.
Econ Command Position
Humidifer Act.Curr.Pos.
Humidifier Command Pos.
Ht.Coil Act.Current Pos.
Ht.Coil Command Position
BP 1 Actuator Curr.Pos.
BP 1 Command Position
BP 2 Actuator Curr.Pos.
BP 2 Command Position
GENERAL OUTPUTS
Humidifier Relay
Remote Alarm / Aux Relay
VFD_DATA
VFD1 Status Word 1
VFD1 Actual Speed %
VFD1 Actual Motor rpm
VFD1 Actual Motor Freq
VFD1 Actual Motor Amps
VFD1 Actual Motor Torque
VFD1 Actual Motor Power
VFD1 DC Bus Voltage
VFD1 Output Voltage
VFD1 Transistor Temp (C)
VFD1 Cumulative Run Time
VFD1 Cumulative kWh
VFD1 Last Fault Code
VFD1 DI1 State
VFD1 DI2 State
VFD1 DI3 State
VFD1 DI4 State
VFD1 DI5 State
VFD1 DI6 State
VFD1 AI1 (% of range)
VFD1 AI2 (% of range)
VFD2 Status Word 1
VFD2 Actual Speed
VFD2 Actual Motor rpm
VFD2 Actual Motor Freq
VFD2 Actual Motor Amps
VFD2 Actual Motor Torque
VFD2 Actual Motor Power
VFD2 DC Bus Voltage
VFD2 Output Voltage
VFD2 Transistor Temp (C)
VFD2 Cumulative Run Time
VFD2 Cumulative kWh
VFD2 Last Fault Code
APPENDIX B — CCN TABLES (CONT)
Table L — STATUS DISPLAY TABLES (cont)
DISPLAY NAME
0 to 100
0 to 100
On/Off
On/Off
On/Off
On/Off
On/Off
On/Off
On/Off
On/Off
On/Off
0 to 100
On/Off
On/Off
On/Off
On/Off
On/Off
On/Off
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
On/Off
On/Off
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
RANGE
UNITS
%
OVA_SPD
%
OVB_SPD
CMPA1
CMPA2
CMPA3
CMPB1
CMPB2
CMPB3
%
CMPA1CAP
MLV
HUM3WVAL
%
COND_EXV
%
BYP_EXV
HS1
%
HTMG_CAP
HS2
HS3
HS4
HS5
HS6
HIR
%
ECONOPOS
%
ECON2POS
%
ECONOCMD
%
ECN2RPOS
%
ECN2CPOS
%
HUMDRPOS
%
HUMDCPOS
%
HTCLRPOS
%
HTCLCPOS
%
BP1_RPOS
%
BP1_CPOS
%
BP2_RPOS
%
BP2_CPOS
HUMIDRLY
ALRM
VFD1STAT
%
VFD1_SPD
VFD1rpm
VFD1FREQ
amps
VFD1AMPS
%
VFD1TORQ
VFD1PWR
volts
VFD1VDC
volts
VFD1VOUT
VFD1TEMP
hours
VFD1RUNT
VFD1KWH
VFD1LFC
VFD1_DI1
VFD1_DI2
VFD1_DI3
VFD1_DI4
VFD1_DI5
VFD1_DI6
%
VFD1_AI1
%
VFD1_AI2
VFD2STAT
%
VFD2_SPD
VFD2rpm
VFD2FREQ
amps
VFD2AMPS
%
VFD2TORQ
VFD2PWR
volts
VFD2VDC
volts
VFD2VOUT
VFD2TEMP
hours
VFD2RUNT
VFD2KWH
VFD2LFC
202
POINT NAME
WRITE STATUS
forcible
forcible
forcible