Maximum permissible loads [N] on the pump flange
Force
Bredel 40
F1
1000
F2
200
F3
500
Motor
The motor connection must meet the local applicable regulations. A thermal safety device should
reduce the risk of a motor overload. For connecting PTC thermistors (if present) a special thermistor
relay must be used. In case of doubt, contact your Bredel representative for advice.
Refer to the documentation supplied with the electric motor for information on how to connect the
motor to your power supply.
Frequency controller
WARNING
A frequency controller that is fitted without manual control can start the
pump automatically when power is applied.
If the hose pump is fitted with a frequency controller, consider the following points:
•
Take precautions so the motor does not restart automatically after an unscheduled stop. In the
event of a power or mechanical failure, the frequency controller stops the motor. When the
cause of the failure is removed, the motor can restart automatically. The automatic restart can
be dangerous in certain pump installations.
•
All control cables outside the enclosure must be shielded and have a cross sectional area of at
2
least 0.22mm
your Bredel representative for advice.
m-bredel-40-100-en-05
F2
F1
F3
Bredel 50
1400
300
700
. The shielding must be connected to earth at one end. In case of doubt, contact
Bredel 65
Bredel 80
1400
2000
300
700
1000
Bredel 100
2000
400
400
1000
31