ABOUT THIS MANUAL Purpose This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference. Scope This manual provides safety and installation guidelines as well as information on tools and wiring. SAFETY INSTRUCTIONS WARNING: This chapter contains important safety and operating instructions.
INTRODUCTION This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
INSTALLATION Unpacking and Inspection Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1 User manual x 1 Communication cable x 1 ...
Recommended battery cable size: Model Wire Size Torque value(max) Cable (mm 3KVA/5KVA 1 x 2AWG 2 Nm Please follow below steps to implement battery connection: 1. Remove insulation sleeve 18 mm for positive and negative conductors. 2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
Page 8
5. Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver 6.
AC input. The recommended spec of AC breaker is 32A for 3KVA and 50A for 5KVA. CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
To reduce risk of injury, please use the proper recommended cable size as below. Model Wire Size Cable (mm Torque value(max) 3KVA/5KVA 1 x 12AWG 1.2 Nm WARNING: Because this inverter is non-isolated, only three types of PV modules are acceptable: single crystalline, poly crystalline with class A-rated and CIGS modules.
4. Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Screw two wires tightly in clockwise direction. Recommended tool: 4mm blade screwdriver Final Assembly After connecting all wirings, please put bottom cover back by screwing two screws as shown below.
OPERATION Power ON/OFF Side view of unit Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit. Operation and Display Panel The operation and display panel, shown in below chart, is on the front panel of the inverter.
LCD Display Icons Icon Function description Input Source Information Indicates the AC input. Indicates the PV input Indicate input voltage, input frequency, PV voltage, charger current (if PV in charging for 3K models), charger power, battery voltage. Configuration Program and Fault Information Indicates the setting programs.
Page 14
In battery mode, it will present battery capacity. Load Percentage Battery Voltage LCD Display < 1.85V/cell 1.85V/cell ~ 1.933V/cell Load >50% 1.933V/cell ~ 2.017V/cell > 2.017V/cell < 1.892V/cell 1.892V/cell ~ 1.975V/cell Load < 50% 1.975V/cell ~ 2.058V/cell > 2.058V/cell Load Information Indicates overload.
LCD Setting After pressing and holding ENTER button for 3 seconds, the unit will enter setting mode. Press “UP” or “DOWN” button to select setting programs. And then, press “ENTER” button to confirm the selection or ESC button to exit. Setting Programs: Program Description...
Page 16
11, the 10A. inverter will apply charging current from program 02 for utility charger. Available options in 3KVA model: 23.0V (default) Setting range is from 22V to 25.5V. Increment of each click is 0.5V. Setting voltage point back to utility source when selecting “SBU priority”...
Page 17
If this inverter/charger is working in Line, Standby or Fault mode, charger source can be programmed as below: Utility first Utility will charge battery as first priority. Solar energy will charge battery only when utility power is not available. Solar first Solar energy will charge battery as first priority.
Page 18
(C.V voltage) If self-defined is selected in program 5, this program can be set up. Setting range is from 25.0V to 31.5V for 3KVA model and 48.0V to 61.0V for 5KVA model. Increment of each click is 0.1V. 3KVA default setting: 27.0V 5KVA default setting: 54.0V...
Setting range is from 25.0V to 31.5V for 3KVA model and 48.0V to 61.0V for 5KVA model. Increment of each click is 0.1V. 60min (default) Setting range is from 5min to 900min. Increment of each click is 5min. Battery equalized time 120min (default) Setting range is from 5min to 900 min.
Page 20
PV current = 2.5A PV current PV power = 500W PV power AC and PV charging current=50A PV charging current=50A Charging current AC charging current=50A...
Page 21
AC and PV charging power=500W PV charging power=500W Charging power AC charging power=500W Battery voltage=25.5V, output voltage=230V Battery voltage and output voltage Output frequency=50Hz Output frequency Load percent=70% Load percentage...
Page 22
When connected load is lower than 1kVA, load in VA will present xxxVA like below chart. Load in VA When load is larger than 1kVA (≧1KVA), load in VA will present x.xkVA like below chart. When load is lower than 1kW, load in W will present xxxW like below chart.
Operating Mode Description Operation mode Description LCD display Charging by utility and PV energy. Charging by utility. Standby mode Note: No output is supplied by the *Standby mode: The inverter unit but it still can charge is not turned on yet but at this batteries.
Page 24
Operation mode Description LCD display Charging by utility and PV energy. The unit will provide output power from the mains. It will also charge the battery at line mode. Charging by utility. If “solar first” is selected as output source priority and solar energy is not sufficient to provide the load, solar energy and the utility will provide the loads and charge the battery at the...
Power from PV energy only. The unit will provide output Battery Mode power from battery and PV power. Battery Equalization Description Equalization function is added into charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates.
Page 26
However, in Equalize stage, when battery equalized time is expired and battery voltage doesn’t rise to battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalization voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.
Fault Reference Code Fault Code Fault Event Icon on Fan is locked when inverter is off. Over temperature or NTC is not connected well. Battery voltage is too high Battery voltage is too low Output short circuited or over temperature is detected by internal converter components.
CLEARANCE AND MAINTENANCE FOR ANTI-DUST KIT Overview Every inverter is already installed with anti-dusk kit from factory. Inverter will automatically detect this kit and activate internal thermal sensor to adjust internal temperature. This kit also keeps dusk from your inverter and increases product reliability in harsh environment.
SPECIFICATIONS Table 1 Line Mode Specifications INVERTER MODEL 3KVA 5KVA Input Voltage Waveform Sinusoidal (utility or generator) Nominal Input Voltage 230Vac 170Vac± 7V (UPS); Low Loss Voltage 90Vac± 7V (Appliances) 180Vac± 7V (UPS); Low Loss Return Voltage 100Vac± 7V (Appliances) High Loss Voltage 280Vac±...
Page 30
Table 2 Inverter Mode Specifications INVERTER MODEL 3KVA 5KVA Rated Output Power 3KVA/3KW 5KVA/5KW Pure Sine Wave Output Voltage Waveform 230Vac± 5% Output Voltage Regulation 50Hz Output Frequency Peak Efficiency Overload Protection 5s@≥130% load; 10s@105%~130% load 2* rated power for 5 seconds...
Page 31
Table 3 Charge Mode Specifications Utility Charging Mode INVERTER MODEL 3KVA 5KVA Charging Algorithm 3-Step AC Charging Current (Max) 100Amp (@V =230Vac) Bulk Charging Flooded Battery 29.2 58.4 Voltage AGM / Gel Battery 28.2 56.4 Floating Charging Voltage 27Vdc 54Vdc...
TROUBLE SHOOTING Problem LCD/LED/Buzzer Explanation / Possible cause What to do Unit shuts down LCD/LEDs and buzzer automatically will be active for 3 The battery voltage is too low 1. Re-charge battery. during startup seconds and then (<1.91V/Cell) 2. Replace battery. process.