Download Print this page

Troubleshooting - Sears BugWacker 557-5199 Owner's Manual

Electronic insect killer

Advertisement

SEARS ELECTRONIC
INSECT KILLER
- MODEL NO. 833.14334
REF. NO.
PART NO.
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
554 722
596 1565 P02
567 420
596 784
555 5314 SR
245 6260 P27
596 785
544 5288
544 3750
245 6245 P28
532 30O6
576 4890
505 3370
HANGING
RING
THREADED
NIPPLE, 1" LONG
NEOPRENE WASHER
REDUCING
BUSHING
HOOD
THREAD CUTTING SCREW, F, 8-32 x 3/8
LOCKNUT
GRID SPACER
SPACER INSULATOR
SHEET METAL SCREW_ NO. 8 x 1/2
BALLAST
TRANSFORMER
BULB SOCKET ASSY
552
555
512
552
531
512
571
245
544
245
512
530
553
553
505
5O5
245
557
3369 P03
3534
392 P26
5202
2034
5140
5170
6236 Pll
3749
6245 P12
404 P02
2815 S
2846 P01
2847 P01
3377
4031
6260 P25
5199
REFLECTOR
BULB RETAINER
BULB BOOT WIRE, 26'; LONG
TOP PLATE
STARTER
POWER CORD
STARTER SOCKET
SHEET METAL SCREW, NO. 6 x 3/8
MOUNTING
INSULATOR
SHEET METAL SCREW, NO. 6 x 1/2
HV GRID WIRE
BULB, BLACK LIGHT
INNER GRID
OUTER GRID
BASKET ASSY
PHOTOCELL ASSY
THREAD CUTTING SCREW, F, 8-32 x 1/4
OWNER'S MANUAL
1
1
1
1
I
4
1
5
2
9
2
1
2
2
1
2
1
2
1
2
3
3
3
2
2
1
1
1
1
2
1
5
26
15
PROBLEM
A. Bulbs do not light
and no high voltage
on grid.
B. Bulbs
light
but
no
grid
high
voltage.
C. Grid voltage
present
but bulbs
do not
light.
O.
Intermittent
or
continuous
sparking
between
grids.
POSSIBLE CAUSE
I. No electrical power.
TROUBLESHOOTING
AND
REPAIR
ANALYSIS
CORRECTION
1. Check fuse or circuit breaker.
2. Check extension
cord, (If used,)
1. Shorted
grids.
1, Lamp(s)
not
seated properly.
2. Starter
defective.
3. Burned-out
bulb(s).
1. Gap between
grids is too small.
2. Grid clogged with foreign material.
3. Grid not seated in insulaitor.
1. Examine
grids to see if inner and outer
grids are free from
foreign
material,
dirt
or a build-up
of dead insects.
2. Check to make sure inner grid _nd outer grid
are not touching.
Use insulated
screwdriver.
1. Check all sockets
for proper
seating and
alignment.
,,
2. Replace if needed.
,'
3. Replace
if needed.
1. Unplug
unit
and adjust grids by bending
back into
alignment
using screwdriver
blade.
2. Clean grid using an air blower.
3. Look
for proper
grid seating at all insulators,
Any problems
you encounter
that are not corrected
by the action
recommended
in this chart
should
be
referred
to your
nearest Sears Service Center.