  • Page 3 At iSpring, we strive to develop products to the highest standards and aim to make excellent drinking water accessible for all households. With affordable pricing, reliable quality, prompt delivery, and top-notch customer service, we hope to assist in bringing you great water for years to come.
  • Page 4: Table Of Contents

    Installation Precautions ....................8 Installation Instructions ....................9 Operation Tips......................12 Programming the Central Softener System ............... 12 Emergency Response ....................16 Maintenance ......................16 Troubleshooting ......................17 Warranty iSpring Standard Limited Warranty (End-Users Only) ..........Warranty Registration Form ..................
  • Page 5: User Information & Guidelines

    ● The unit should be placed only on flat surfaces. Do not mount it on a wall. ● This product is designed for residential use. Contact iSpring customer service to inquire about using it in non-residential settings.
  • Page 6: Dimensions

    Dimensions TOP VIEW SIDE VIEW FRONT VIEW Page 4 www.123filter.com | +1 (678) 261 - 7611 | support@123filter.com...
  • Page 7: Product Operation & Specifications

    Product Operation & Specifications Though testing was performed under standard laboratory conditions, the system's performance may vary based on local water conditions and quality. SPECIFICATIONS Working Pressure Limits (min./max.) 21~64 psi 40~100 ° F Water Temperature Limits (min./max.) (4~39 ° C) Required Riser Pipe Diameter 1.050 inch (26.7 mm) Input: AC 120 V, 60 Hz...
  • Page 8: Material Details

    Material Details 1. Inspect the packaging for the following components: One machine and these accessories are included: ① power adapter (white box, 1 pcs.) ② sewage and overflow pipe (a translucent pipe, 1 pcs.) ③ stainless steel clamps (in the PE bag, 2 pcs.) ④...
  • Page 9: General Product Information

    General Product Information iSpring's whole-house central softeners provide large water output, optimal water softening, and stable performance. They can also be fully automatic and intelligent in operation, regeneration, and dynamic salt dissolution. In addition, these softeners not only meet the needs of household bathing, laundry, cleaning, water heaters, etc., but they also provide softened water for businesses,...
  • Page 10: Notice

    Notice Warning ◼ This system can only be used with 120V/60Hz unidirectional AC power. ◼ Do not place objects on top of the power cord, and set the unit in an area where the power cord will not be stepped on or tripped over. ◼...
  • Page 11: Installation Instructions

    Do not remove the clips when the system is in operation; relieve the pressure before removing the clips. (3) Equipment Installation It is highly recommended that you watch the video How to Install iSpring WCS45KG Whole House Water Central Softener | DIY Installation on YouTube. www.123filter.com | +1 (678) 261 - 7611 | support@123filter.com...
  • Page 12 Step 1. Confirm proper installation conditions, unpack the equipment and verify that all accessories are present. Prepare the installation tools and confirm that the installation site's water inlet and outlet pipes, power supplies, drain tube, and floor drain meet the appropriate requirements. Step 2.
  • Page 13 tank until the water is completely clean. The flushing time should not be less than 10 minutes, and the tank's air should be completely exhausted. All keys will lock after 3 minutes during standby. Press and hold the "MENU" or "SETTINGS"...
  • Page 14: Operation Tips

    Operation Tips • The product can be generally used after installation and commissioning have been completed. With an uninterrupted power supply, the user does not need to perform other operations on the machine. • The automatic regeneration start time default is to start late at night. The water is not treated and should not be used during this time.
  • Page 15 (3) Programming Levels There are four levels of the valve program: a. Settings Press and hold "Menu" or "SETTINGS" for 3 seconds to enter. Use the "UP" and "DOWN" buttons to modify the value. Press the "Menu" or "SETTINGS" button once to confirm and switch to the following parameter setting, the entire menu shown below.
  • Page 16 b. Factory Options Press and hold "Menu" and "Set/Regen" or "SETTINGS" and "MANUAL REGEN." at the same time for 3 seconds to enter. Press "Set/Regen" or "MANUAL REGEN." to confirm and switch to the following parameter setting, the entire menu shown below. Use the "UP" and "DOWN" buttons to modify the value. Press the "Menu"...
  • Page 17 c. Advanced Options Press and hold "UP" and "DOWN" at the same time for 3 seconds to enter. Press "Set/Regen" or "MANUAL REGEN." to confirm and switch to the following parameter setting, the entire menu shown below. Use the "UP" and "DOWN" buttons to modify the value. Press the "Menu"...
  • Page 18: Emergency Response

    Media needs to be refilled only when the system reaches capacity or accidentally gets contaminated. The media replacement process needs to be conducted with a professional or under professional guidance. For related questions, contact the iSpring Customer service team. •...
  • Page 19: Troubleshooting

    Foreign matter in the flow control Remove foreign objects. The effluent water has Low quality from the water source Contact iSpring. High hardness Incorrect regeneration cycle setting Reset the regeneration cycle according to the manual. www.123filter.com | +1 (678) 261 - 7611 | support@123filter.com...
  • Page 20 The machine is leaking Turn off the machine and contact iSpring. Need help with troubleshooting? If you have any questions or find there are missing parts or damage, please call 1-678-261-7611 or visit www.ispringfilter.com When calling, please be prepared to provide the model of your product.
  • Page 22 __________________ __________________ __________________ __________________ ______________________________________________ ____________ ______________ _________________ ___________________________________________ ______ _________________ ___________________________________...