DECLARATION OF QUALITY DECLARATION OF WARRANTY DECLARATION OF PERFORMANCE DoP MEDITERRANEA LINE MODEL MED JOY ISLAND VERSION, LEANING VERSION, WALL SINGLE MODULE, COUPLED MUT 104 Rev. 1 24/02/2020 Gibus S.p.A. Via Luigi Einaudi, 35 35030 Saccolongo (PD) - ITALY www.gibus.it - gibus@gibus.it...
Page 3
Pergola. Read in particular the chapter on safety. Dear Customer, thank you for choosing a Pergola by "Gibus", we are pleased to deliver this manual in order to help you to use the product in the best possible way. Please read carefully the recommendations described in the following pages and keep the manual at hand for the Gibus specialist who will be responsible for management and maintenance of the Pergola.
Page 4
Rev. 1 These instructions were translated from Italian (original language). Gibus S.p.A. reserves all rights to this manual, including the right, at any time, to make any necessary changes aimed at improving its products and the manual itself without prior notice.
7 INSTRUCTIONS FOR PROPER INSTALLATION 8 OPERATION AND USE OF THE PERGOLA 9 MAINTENANCE 9.1 Cleaning the brise soleil blades 9.2 Maintenance of the Pergola 9.3 Extraordinary maintenance 10 DISASSEMBLY AND DISPOSAL 10.1 Disposing of the Pergola USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 6
13.2 MED JOY COUPLED ON THE FRONT - ISLAND/LEANED 13.3 MED JOY COUPLED ON THE SIDE - ISLAND/LEANED 13.4 MED JOY 4 MODULES (CROSSED VERSION) - ISLAND/LEANED 14 DOCUMENTATION 14.1 Declaration for correct installation 14.2 Maintenance registry 14.3 Production notes 15 ANNEXES USE AND MAINTENANCE MANUAL www.gibus.com Page...
(Declaration of Performance DoP) are included in APPENDIX 0 and APPENDIX 1 on the last pages of this manual. The original Declaration of Performance DoP issued by the manufacturer is kept by Gibus S.p.A. USE AND MAINTENANCE MANUAL www.gibus.com...
Code MUT 104 Rev. 1 RESPONSIBILITY Gibus SpA is not liable and has no obligations for any accidents to persons or property, which may occur due to: - Failure to follow the instructions in this manual regarding the installation, use and maintenance of the Pergola;...
IMPORTANT: In order to use the Pergola for purposes other than those described above, a specific permission given by the manufacturer is required. Failure to follow the conditions for proper use, voids any warranty given by the manufacturer. USE AND MAINTENANCE MANUAL www.gibus.com Page...
60 seconds that the speed is lower than the set threshold. IMPORTANT: the wind sensor can’t be enabled/disabled from the remote control or control unit but only from the sensor itself. See the specific instructions of the sensor supplied with the accessory box. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Any operation on the electrical system must be carried out by trained personnel only. For any doubt or unintended use, consult the manufacturer before installation. USE AND MAINTENANCE MANUAL www.gibus.com Page...
CHAPTER 3: TECHNICAL DESCRIPTION The Bioclimatic Pergolas of the MED JOY line were designed and built according to the principles of constant innovation, impeccable workmanship and attention to detail by Gibus Total Quality. A system of values designed to ensure complete customer satisfaction.
The Pergola is equipped with several patented systems to facilitate and speed up the installation work and improve the performance of the product: Gibus Patent Side Seal: a side holding system for the blades resting on a seal along ®...
Page 15
In the case of antifreeze system, the differential must have an intervention current of 0.01A (dedicated line). In case of Schuko socket, the differential must be of the AC type and the intervention current of 0.03A. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Bioclimatic Pergola or placed in the accessory box. These instructions must be read, annexed to this manual and keep in good condition for any subsequent consultation. NOISE LEVEL The measured noise (sound pressure level) was less than 55 dB (A). USE AND MAINTENANCE MANUAL www.gibus.com Page...
Width up to 690 cm MED JOY WALL (Basic Module) With 4 wall attachments: Width up to 450 cm Projection up to 610 cm With 6 wall attachments: Width up to 450 cm Projection up to 690 cm USE AND MAINTENANCE MANUAL www.gibus.com Page...
Side view Front View WIDTH “L ” (cm) 1 Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades. G = Legs. L = Brise soleil blades. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 19
Violent storm Storm Strong gale Gale High wind Strong breeze Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “L” “L” “S” “S” USE AND MAINTENANCE MANUAL www.gibus.com Page...
Side view Front View WIDTH “L ” (cm) 1 Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades. G = Legs. L = Brise soleil blades. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 21
Violent storm Storm Strong gale Gale High wind Strong breeze Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “L” “L” “S” “S” USE AND MAINTENANCE MANUAL www.gibus.com Page...
3 LEGS max. S x L 4.50 x 6.90 Side view Front View PROJECTION “S” (cm) 1 Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades. G = Legs. L = Brise soleil blades. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 23
Violent storm Storm Strong gale Gale High wind Strong breeze Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “S” “S” “L” “L” USE AND MAINTENANCE MANUAL www.gibus.com Page...
Side view Front View WIDTH “L ” (cm) 1 Module n° n° Legend: kg = Total pergola weight including the supporting structure and brise soleil blades. AP = Wall fixing. L = Brise soleil blades. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 25
Gale High wind Strong breeze Wind Resistance [kg/m Wind Resistance [kg/m Without Integrated ZIP Screens Integrated ZIP Screens closed or semi-closed on 2 or 4 sides “L” “L” AP L AP L “S” “S” USE AND MAINTENANCE MANUAL www.gibus.com Page...
Up to 570 cm. From 610 cm to 690 cm. Projection Projection BASE COUPLED module module MED JOY FRONTAL LEANING VERSION WITH COUPLING MODULE TYPE 1 COUPLING Up to 610 cm. From 610 cm to 690 cm. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 27
MED JOY LATERAL LEANING VERSION WITH COUPLING MODULE TYPE 1 COUPLING Up to 610 cm. From 610 cm to 690 cm. MED JOY LATERAL LEANING VERSION WITH COUPLING MODULE TYPE 2 COUPLING Up to 610 cm. From 610 cm to 690 cm. USE AND MAINTENANCE MANUAL www.gibus.com Page...
IMPORTANT: unpack using scissors with rounded tips in order not to damage aluminium painting, do not use cutters. The packaging material should be disposed of or recycled in accordance with the regulations in force in the Country of destination of the product. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Be especially careful when working at height. The installation isn’t usually performed directly by staff from Gibus S.p.A. but by installers appointed by the authorized dealer, buyer or customer. The client is responsible under the law to entrust the installation to an expert staff, complying to the installation rules listed in this manual.
Provide a cable with the features indicated in the table in paragraph 3.2. WARNING: if the Pergola is installed at a height from the walkable floor lowest than 2,30 m in its lowest travel point, it is necessary to use the “man present” control. USE AND MAINTENANCE MANUAL www.gibus.com Page...
The 6 channel/42 position version is given as an example. The transmitter is already matched to the motor control unit for the Bioclimatic Pergola. The motor control unit is stored in the transmitter channel/group 1. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Follow the “Installation Instructions” attached to this manual or enclosed in the accessory box or part of the packaging. IMPORTANT: after installation the declaration for proper installation must be compiled by the installer (Sec. 14 par. 1). USE AND MAINTENANCE MANUAL www.gibus.com Page...
IMPORTANT!: the wind and rain sensors, if any, have already been set up at the factory. Position them properly and set the thresholds according to the instructions given in the sensor boxes. For the other sensors, follow the specific installation instructions. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 34
The 6 channel/42 position version is given as an example CHANNEL ON –100% BRIGHTNESS 75% BRIGHTNESS 50% BRIGHTNESS CHANNEL CHANGE 25% BRIGHTNESS KEYS DIM + DIM - The intensity level of the led light is 25% when the motor is operating. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 35
IMPORTANT! If something has blocked the opening or closing of the blades, continue the opening or closing with the “man present” command. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 36
IMPORTANT!: in the case of failures, turn to you dealer and if required only ask for Gibus original spare parts. ATTENTION! In the case of fault or when searching for faults, respect the safety measures. In particular when searching for or repairing any faults to the electric components, there is the risk or fatal electric shock.
Compulsory maintenance required by the end of the 2 year and the following maintenance operations for extending the warranty year after year must be carried out by a Gibus technician and must minimally include an inspection of the correct blade movement, positioning of the endstops in opening and closing, making sure that the wind sensor is working if it is present and the conditions of the seals.
OK/NO CHECK THE GOOD STATE AND TIGHTNESS OF THE NUTS AND BOLTS □ ____ for a Gibus specialised technician. CHECK THE FLOOR AND WALL ATTACHMENTS ARE IN PERFECT CONDITION □ ____ CHECK THE CONDITION AROUND THE ATTACHMENTS (ESPECIALLY THAT THERE ARE NO CRACKS AND THAT THE SCREWS ARE TIGHT), IF THERE ARE PROBLEMS INFORM THE CUSTOMER □...
CHAPTER 10: DISMANTLING AND DISPOSAL CAUTION: dismantling of the Pergola must be carried out by qualified and trained staff. Ask for a specialized Gibus technician at the Service Department. CAUTION: dismantling of the Pergola must be carried out applying all the safety provisions as per installation: see chapter “SAFE INSTALLATION”...
(procedure in chapter 2). The pergola is not power supplied. Power supply the pergola. The remote control is not matched or the Match the remote control or replace the batteries are drained or it is broken. batteries. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Page 41
Check the connections to the terminals. unit. Faulty anemometer. Replace the anemometer. Check the specific instruction manuals Malfunction not included among for the control units attached to this the above. manual, or contact the technical service centre. USE AND MAINTENANCE MANUAL www.gibus.com Page...
5th year. In any case, the maintenance operation must be carried out by a Gibus specialized technician. The call and the cost of labour will be borne by the customer. The warranty for the 3rd, 4th and 5th year, only provides the replacement of components deemed faulty by Gibus S.p.A.
5 years. The installation, as well as the required maintenance, must be carried out only by a specialized Gibus technician; both must be proven in this warranty statement (filling in the specific parts of this manual). The electrical and electronic parts (engine - automatisms - switches), concerning the product, shall be provided by Gibus S.p.A.
Use Gibus original spare parts to keep the warranty valid. Accordingly, a compulsory maintenance operation within the end of the 3rd year from the installation date is to be required to the Gibus specialized technician and that will extend the warranty to the 4th year; a compulsory maintenance in the 4th year from the installation date will extend the warranty to the 5th year.
Page 49
Code MUT 104 Rev. 1 ADDITIONAL Installation Notes: ADDITIONAL Mandatory Maintenance Notes: USE AND MAINTENANCE MANUAL www.gibus.com Page...
Code MUT 104 Rev. 1 14.2 MAINTENANCE AND NOTE REGISTER Operation description Full name and signature Date (including components replacement) specialized technician NOTES: 14.3 PRODUCTION NOTES See the product sheet attached to the back cover. USE AND MAINTENANCE MANUAL www.gibus.com Page...
Designed use: Drop awning for outdoor use Name and address of the manufacturer: Gibus S.p.A. - Via Einaudi, 35 - 35030 Saccolongo www.gibus.it - E-mail: gibus@gibus.it Assessment and check system of constant performance: System 4 Performance declared in accordance with the UNI EN 13561 harmonized standard:...
Page 52
HOLOGRAM Gibus S.p.A. Via Luigi Einaudi, 35 35030 Saccolongo (PD) - ITALIA www.gibus.it - gibus@gibus.it PRODUCT SHEET...
Need help?
Do you have a question about the MEDITERRANEA Series and is the answer not in the manual?
Questions and answers