4. QUICK START PROCEDURE
NOTE:
Do not insert SIM card before the first programming of communicator as it
may block the card if PIN code is required for the card.
This chapter is purposed for users that possess experience regarding GPRS
data transmission systems and who work with OSM.Server server. Other
users shall skip this chapter and go to chapter 5 of this Manual.
As many users possess protected facilities spread at vast locations, local programming
of communicator is not always available (with computer keyboard and programming
cable).
Two phases comprise programming in this option:
a) sending to communicator of main parameters (with SMS) that enable
connection to communication server (OSM.Server system).
b) full configuration of device with remote programming (EBS Config and
OSM.Server).
Quick start procedure:
a) insert into device SIM card with PIN code 1111 or without PIN code.
b) connect power supply for module,
c) send to SIM card number with SMS parameters related to connection of device
to communication server (OSM.Server)
d) waiting for moment, when device indicates connection to server
Note: Connection to server is possible if the device was registered into it.
Registration procedure has been described in OSM.Server Operation Manual.
e) complete, remote programming with EBS Config.
SMS text message shall provide the following information:
<communicator's service code>█SERVER=<server address>█PORT=<server
APN=<access point name>█UN=<user ID
PW=<user password>
Where:
█: space (every parameter shall be separated with space – blank character)
<communicator's service
<server
address>: address of communication server purposed for collection of
communicator signals e.g. 89.123.115.8. In case address is provided as domain e.g.
block.autostrada.com, SMS message shall include DNS1 parameter (address of main
DNS server)
<server
port>: Number of port in server that receives messages from a device
<access point
name>: defines access point name to GSM network.
If private network is used, SMS message shall provide the following parameters:
UN=<user ID number>
Exemplary SMS is as follows (if we use public network and provide server address as
IP):
PX200NB – Manual
code>: factory settings – 1111.
and
PW=<user
password>.
number>█
port>█
Page 13 / 57
Need help?