PSEN 1.1p-20
Technical details
General
Certifications
Sensor's mode of operation
Coding level in accordance with EN ISO 14119
Design in accordance with EN ISO 14119
Classification in accordance with EN 60947-5-3
Electrical data
Supply voltage
Voltage
Kind
Voltage tolerance
Max. switching frequency
Lowest operating current (Im)
Switching voltage
Internal resistance
Max. switching current, safety contacts
Max. breaking capacity, safety contacts
Times
Reaction time (actuator removed)
Environmental data
Ambient temperature
Temperature range
Climatic suitability
In accordance with the standard
Humidity
Max. operating height above sea level
EMC
Vibration
In accordance with the standard
Frequency
Amplitude
Shock stress
Acceleration
Duration
Airgap creepage
Pollution degree
Rated insulation voltage
Rated impulse withstand voltage
Protection type
Housing
Connector
Operating distances
Assured operating distance Sao
Operating Manual PSEN 1.1p-20
20990-EN-11
CE, EAC, TÜV, UKCA, cULus Listed
Magnetic
Low
4
PDDB
24 V
DC
-20 %/+20 %
1 Hz
1 mA
24 V
10 Ohm
0,5 A
10 W
2 ms
-10 - 55 °C
IEC 60068-2-30
93 % r. h. at 40 °C
2000 m
EN 60947-5-3
EN 60947-5-2
10 - 55 Hz
1 mm
30g
11 ms
3
25 V
0,33 kV
IP65, IP67
IP67
8 mm
| 15