Description Of Functions And Graphical Contexts Displayed By Lmc1X Control Panel; Graphic Context - Display Error E88 - Kober C38GC45V1 User Manual

Condensing wall-mounted gas boiler
Table of Contents

Advertisement

KÖBER SRL
CONDENSING WALL HEATING POWER PLANT C38GC45V1
VADURI BRANCH
Table 6.2: Description of graphic symbols in the LCD display area
Fig. 6.2 Control panel LMC202 display
Key
Annotation
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
D1
D2
D3
D4
D5
6.2

Description of functions and graphical contexts displayed by LMC1X control panel

6.2.1

Graphic context - Display error E88

When the boiler is switched on, the welcome message "OFF and
error E88 (
).
REV 01.08.2022
Indicates whether the set operating mode is WINTER - active symbol
Indicates the status of the "Vacation" function - active / inactive
Indicates whether the DHW production mode is by boiler - active symbol
Indicates the status of the "Antifreeze" function - active / inactive
Indicates the status of the boiler (OFF = active symbol, ON = inactive symbol)
Indicates that there was an unsaved change in the parameters in the EEPROM memory
(flashes - in the SERVICE submenu); indicates the need to perform VTP (periodic technical
check) (symbol flashes)
Indicates the status of the "Comfort" Function - active / inactive
Indicates serial communication status (RS232 with computer) - active / inactive
Indicates whether the set operating mode is SUMMER - (active symbol)
Displays the presence of the flame
Indicates the operation of the boiler in DHW mode, flashes (DHW production)
Indicates the operation of the boiler in AT mode, flashes (district heating)
Indicates the modulation stage
"HOME" symbol - active in the presence of the outdoor sensor connected to the control
panel
Displays temperature (° C), parameter values
Displays temperature (° C), parameter index, error counter
Displays the pressure in ex format. 1.5 bar, other texts ("On", "OFF", "HELLO" etc.)
Displays outdoor temperature (° C) - active in the presence of the outdoor sensor
Displays indoor temperature (° C) - active in the presence of indoor temperature sensor - in
correlation with the S14 symbol
Description:
0.0
bar " immediately followed by the entry of the boiler in
page 20 of 37