Download Print this page
Sealey AK1998.V3 Manual
Sealey AK1998.V3 Manual

Sealey AK1998.V3 Manual

80-1000v non-contact voltage detector

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instruction
gloves
manual
1. SAFETY
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using tools.
NOTE: FOR USE BY COMPETENT PERSONS Anyone using this instrument should be knowledgeable and trained about the risks involved
with measuring voltage, especially in an industrial setting, and the importance of taking safety precautions and of testing the instrument before
and after using it to ensure that it is in good working condition.
Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.
9
DO NOT use the unit if it is wet or damaged.
8
DO NOT operate with the case open.
8
Only use the tester as specified, or the protection supplied by the voltage detector can be compromised.
9
DO NOT rely on the voltage detector to detect the presence or absence of voltage on a conductor for safety purposes. A single pole non-
8
contact voltage detector such as this product is not suitable to determine if a circuit is hazardous. A volt meter or 2-pole voltage detector
is necessary to confirm the absence of hazardous voltage prior to commencing work.
DO NOT use if the light/buzzer fails to operate.
8
DO NOT expose the unit to extremes in temperature or high humidity. Refer to 'Specifications' as failure to observe these precautions
8
may result in severe injury and can damage the tester.
Test on a known voltage first to make sure that the voltage tester operates correctly. This should be done both before and after each
9
repair.
NOTE: When using the voltage detector if tip does not glow, voltage could still be present. The detector indicates active voltage in the presence
of electric fields of sufficient strength generated from the source mains voltage. If the field strength is low, the detector may not provide indication
of live voltages. Lack of an indication occurs if the detector is unable to sense the presence of voltage, which may be influenced by
several factors such as shielded wire and cables, thickness and type of insulation, distance from the voltage source, condition of the detector
and batteries.
Hold the tester behind the tactile barrier.
9
Always have detected faults to be rectified by a qualified electrician.
9
CAUTION with voltages above 30V AC as a shock hazard may exist.
WARNING! The AK1998.V3 will not detect voltages in cables connected to a centre tapped earth supply e.g. 110V transformer
or generator.
2. INTRODUCTION
Non-contact voltage detector with LED/audible indication. Designed for quickly identifying wire and cable breaks as well as detecting voltage in fuses,
cables, switches, outlets, lighting fixtures and many more. Features two selectable sensitive settings low gear (L) and high gear (H) detecting voltage
ranges from 80V – 1000V. Requires 2 x AAA batteries (not included).
3.
SPECIFICATION
Model No: ...................................................... AK1998.V3
Altitude: ....................................................... up to 2000m
Dimensions: .........................................26 x 22 x 160mm
Display: .............................................................Red LED
Frequency: .........................................................50-60Hz
Overvoltage Category: .......................................... CATIII
Operating Temperature: ......... 0°C to +40°C at RH <80%
Voltage Range: ................................................80-1000V
© Jack Sealey Limited
80-1000V NON-CONTACT VOLTAGE DETECTOR
AK1998.V3
MODEL NO:
Wear protective
Indoor use only
clothing
Original Language Version
AK1998.V3 Issue:5
24/05/23

Advertisement

loading

Summary of Contents for Sealey AK1998.V3

  • Page 1 AK1998.V3 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk...