Download Print this page
Amana LPM-10 Manual
Amana LPM-10 Manual

Amana LPM-10 Manual

Conversion kit 34" modulating furnace natural gas to l.p. gas conversion kit for furnaces equipped with white-rodgers 36j27 series gas valves

Advertisement

Quick Links

NATURAL GAS TO L.P. GAS CONVERSION KIT FOR
FURNACES EQUIPPED WITH WHITE-RODGERS 36J27 SERIES GAS VALVES
ACCESS PLUG - (PRESSURE FINE ADJUSTMENT)
SCREW IS LOCATED BENEATH PLUG)
L.P . LABEL (SUPPLIED WITH KIT)
1/8 - NPT
OUTLET
PRESSURE
TAP
.093 SOCKET HEAD
SCREW OUTLET
PRESSURE TAP
(SOME MODELS)
Figure 1 - 36J27 Modulating Gas Valve
APPLICATION
This modulating Natural Gas to modulated L.P. Gas Conversion kit
allows the 36J27 Series gas valves to be used on L.P. applications.
THIS CONVERSION KIT IS FOR USE WITH WHITE-RODGERS 36J27
SERIES GAS VALVES ONLY. Tools required for the conversion are
listed below.
IOG-7004
November 2018
LPM-10 CONVERSION KIT
34" MODULATING FURNACE
DO NOT DISCARD - RETAIN THESE INSTRUCTIONS FOR FUTURE USE
JUMPER (SUPPLIED WITH KIT)
ON/OFF SWITCH
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500 • Houston, TX 77056
© 2018 Goodman Manufacturing Company, L.P.
i
s a registered trademark of Maytag Corporation or its related companies and is used under license
to Goodman Company, L.P., Houston, TX, USA. All rights reserved.
Required Tools for Conversion Kit
Q'ty
1
Needle-Nose Pliers
1
7/16" Box Wrench
1
1/4" Nut Driver
1
1/8" Flat Blade Screwdriver
Manometer to read inlet and outlet pressure of the
1
gas valve (minimum range: 0"- 20" W.C.)
Gas leak detection solution like a soap and water
solution. Always wipe the solution from the joints
when testing is completed.
Only personnel that have been trained to install, adjust, service
or repair (hereinafter, "service") the equipment specified in
this manual should service the equipment. The manufacturer
will not be responsible for any injury or property damage
arising from improper service or service procedures. If you
service this unit, you assume responsibility for any injury or
property damage which may result. In addition, in jurisdictions
that require one or more licenses to service the equipment
specified in this manual, only licensed personnel should service
the equipment. Improper installation, adjustment, servicing
or repair of the equipment specified in this manual, or
attempting to install, adjust, service or repair the equipment
specified in this manual without proper training may result in
product damage, property damage, personal injury or death.
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
1
Description
-
0140M00513-A

Advertisement

loading
Need help?

Need help?

Do you have a question about the LPM-10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Amana LPM-10

  • Page 1 LPM-10 CONVERSION KIT 34" MODULATING FURNACE NATURAL GAS TO L.P. GAS CONVERSION KIT FOR FURNACES EQUIPPED WITH WHITE-RODGERS 36J27 SERIES GAS VALVES DO NOT DISCARD - RETAIN THESE INSTRUCTIONS FOR FUTURE USE Required Tools for Conversion Kit ACCESS PLUG - (PRESSURE FINE ADJUSTMENT)
  • Page 2 TO CONVERT FROM NATURAL TO L.P. GAS L.P. GAS PRESSURE CHECK 1. Shut OFF gas supply at manual shutoff and turn OFF power to L.P. Gas Supply Pressure must be verified with all L.P. appliances the furnace. in operating mode. See Table 1 for the required L.P. gas pressure. Remove access door.
  • Page 3 THIS PAGE LEFT INTENTIONALLY BLANK...
  • Page 4 We use quality materials and components. Finally, every unit is run tested before it leaves the factory. That’s why we know. . .There’s No Better Quality. Visit our website at www.goodmanmfg.com or www.amana-hac.com for information on: • Parts •...