ACTpro-1500 Door Controller – Installation and Operating Instructions
3.3.0.1 Terminal block wiring
Reader
Recommended
Terminal
Wiring colour
Block
SENSE
White
CLOCK/D1 Green
DATA/D0
Blue
+12V/24V
Red
0V/GND
Black
RED
Brown
GREEN
Yellow

3.4 Wiring OSDP readers

When connecting OSDP readers to the ACTpro-1500 family of controllers, ensure that the EOL jumper is
on the last two pins (EOL position) on the last reader only.
Jumper position if controller is in the middle of the
OSDP-bus.
You cannot network ACTpro-1500 controllers via RS485 when OSDP readers are attached. When
connecting controllers via RS485, move the jumper to the first two pins (standard operation).
Some examples of connecting OSDP readers:
Example 1
© Vanderbilt 2020
Controller
Signal Information
Input PIN
SENSE
For Entry readers connect the reader SENSE cable or terminal to
the SENSE input pin. For Exit readers, do not use this input.
CLOCK/D1
This is the clock or strobe signal input on the ACTpro 1520/1500.
DATA/D0
This is the Data input.
+12V/24V
Positive +12V DC Supply voltage for the reader.
0V
0V Supply Voltage for the reader.
RED
Red LED control output from the ACTpro 1520/1500. Connect the
reader brown cable to the terminal marked RED on the controller.
GREEN
Green LED control output from the ACTpro 1520/1500. Connect the
reader green cable or terminal marked GREEN on the ACTpro
controller.
Jumper position if controller is EOL(End Of Line) for the
OSDP-bus.
10
Wiring
A-100667
18.06.2020