Title
Block read data 1
Block read data 2
Block read data 3
Block read data 4
Block read data 5
* Disabled ........... Indicates that the inverter will not be tripped even if a communication error occurs.
Trip ...................The inverter trips when a communication time-over occurs.
Alarm................When a communication time-over occurs, an alarm can be output from the output terminal.
Function
In this case a trip information flashes on and off on the operation panel.
Output terminal function: 78 (RS485 communication error) or 79 (RS485 communication
error reverse)
F-65
Adjustment range
0: No selection
1: Status information
2: Output frequency
3: Output current
4: Output voltage
5: Alarm information
6: PID feedback value
7: Input terminal board monitor
8: Output terminal board monitor
9: VI terminal board monitor
E6581595
Default setting
0
0
0
0
0
6