Page 3
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying. The WM150 has a number of special features: •...
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 OPERATION The following procedures should be followed to test the WM150 for correct operation: 1. After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Connect the power cable to a grounded 13 Amp electrical socket.
Page 6
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 Light Functions: The unit has four LED indicators, located on the side of the unit. The following lists the functions of these lights: 1 - ON / OFF Green solid – Indicates power ON 2 –...
Page 7
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 INSTALATION The WM150 Dehumidifier can be left free standing unit, alternatively can be wall mounted for instructions on mounting the unit please read the following: A full installation kit is included in the package to allow a problem free install. This kit comprises of the following:- 1 X WM150 Dehumidifier 1 X Mounting Bracket...
“Reverse Cycle” defrost mode for approximately 4 minutes before returning to normal operation. If the unit will not defrost, the printed circuit timer board may be defective or the by-pass valve may be inoperable. EIP S F ANY OF THE PRECEDING PROBLEMS OCCUR CONTACT THE...
Page 9
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 REPAIRS Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. If refrigerant gas is lost from the machine, it will be necessary to use a Refrigeration technician to correct the fault.
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 TROUBLESHOOTING EMEDY YMPTOM AUSE 1. Check the power from power Unit inoperative 1. No power to unit supply panel 1. Tighten fan 2. Replace the fan motor 1. Loose fan on shaft 3.
Page 11
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 WM150 SPARE PARTS LIST Description Part Number Product Part Number 11285GL-US PCB Timer 1619522 Controls Display Timer 1619524 Humidity Sensor PCB 1619526 PCB Connecting Cable 2013748 Condenser Coil 2028400 Evaporator Coil 2028401 Filter 2028517...
Page 13
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Page 15
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 WM150 OWNERS MANUAL Page 15 of 16...
Page 16
Drawing No. :- TPC551 Issue :- 1 Date :- 19/05/21 UK Head Office American Sales Office Ebac Industrial Products Ltd Ebac Industrial Products Inc St Helens Trading Estate 700 Thimble Shoals Blvd. Bishop Auckland Suite 109, Newport News County Durham Virginia, 23606-2575 DL14 9AD Tel: +44 (0) 1388 664400...
Need help?
Do you have a question about the Ebac WM150 and is the answer not in the manual?
Questions and answers