5.
Loosen the two captive screws that attach the power connector to the switch, and remove the power connector.
Remove both connectors if you are connecting to two power sources.
6.
Insert the exposed part of the positive wire into the connection that is labeled DC+ and the exposed part of the return wire into the connection labeled DC-.
Be sure that you cannot see any wire lead. Only wire with insulation can extend from the connector.
7.
Use a ratcheting-torque screwdriver to torque the captive screws of the power connector to 0.23 N•m (2.0 in•lb).
Do not exceed the recommended torque.
8.
Connect the other end of the positive wire to the positive terminal on the DC power source.
9.
Connect the other end of the return wire to the return terminal on the DC power source.
When you are testing the switch, one power connection is sufficient. If you are installing the switch and are using a second power source, repeat this procedure with the
second power connector.
The following figure shows the completed DC input wiring on a power connector for a primary power source and an optional secondary power source.

Install the Power Connectors on the Switch

To install the switch power connectors to the front panel of the switch, follow these steps.
1.
Insert one power connector into the Pwr A receptacle on the switch front panel, and the other into the Pwr B receptacle.
Rockwell Automation Publication 1783-IN022A-EN-P - July 2023
Stratix 5200 Ethernet Managed Switches Installation Instructions
8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stratix 5200 1783-CMS6B and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF