STEP 3 Connect the electrical wiring
First, read through the "Electrical requirements" section, and follow these steps.
3-wire system
A
B
L2
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E.
3
/
" (1.9 cm) UL-listed strain relief
4
DC68-03170Z-11_IB_DV7450M_EN_R.indd 23
DC68-03170Z-11_IB_DV7450M_EN_R.indd 23
1. Loosen or remove the center terminal
2. Connect the neutral wire (white or
C
3. Connect the other wires to outer
D (N)
4. Tighten the strain relief screws.
L1
5. Insert the terminal block cover into the
E
• To convert from the 4-wire system
• Ring-type terminals are recommended.
• Connect the power cord and check L1/
block.
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
terminal block screws. Tighten the
screws.
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
If using strap terminals, make sure they
are tightened.
L2/N voltage. If the voltage is low, it
may not heat properly.
English 23