Instructions for Replacement of the Fan Cover for BV5600, BV6000, and BV6600 Blower/Vacuum/Mulchers, Type 1
|
Original fan cover has fallen off and users have sustained a serious laceration to their hand and fingers. Replace fan cover before using blower. Continued use of current fan cover could result in serious hand laceration, change to new fan cover provided and immediately dispose of current fan cover to prevent any injury. |
Step 1: Unplug blower from power source.
Step 2: Remove fan cover by pressing the release button on the power head.
Step 3: Promptly dispose of the original fan cover (figure A Left) following local solid waste disposal or recycling regulations.
Step 4: Fit new fan cover (figure A Right) onto the power head as shown in figure B and push until an audible click is heard.
NOTE: The new fan cover has a raised wall that covers the latch button on the blower.
Step 5: Apply replacement "Type 2" label over "Type 1" on nameplate on side of power head.
Step 6: Make sure new fan cover is securely seated and latched into position before powering blower.
If you need to remove new fan cover, insert a screwdriver or hex key in the slot on the end of the fan cover (located on the back of the power head) and rotate the fan cover to remove it as shown in figure C.
If you have any questions, call BLACK+DECKER at 1-866-937-9805 between 8 a.m. and 5 p.m., Eastern Time, Monday through Friday.