    INSTRUCTIONS FOR OPERATION AND ASSEMBLY Electronic safety-sensor RSS 36-D Table of Contents 1 About this document 1.1 Function 1.2 Target group of the operating instructions: authorised qualified personnel 1.3 Explanation of the symbols used 1.4 Appropriate use 1.5 General safety instructions 2 Product description 2.1 Ordering code...
  • Page 2: Function

    Warning:Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 Appropriate use Products in Schmersal's range are not intended to be used by private end consumers. The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine.
  • Page 3: Product Description

    The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
  • Page 4: Purpose

    2.3 Purpose This non-contact, electronic safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards. In this application, the safety sensor monitors the position of hinged, sliding or removable safety guards by means of the coded electronic actuator. The safety function consists of safely switching off the safety outputs when the safety guard is opened and maintaining the safe switched off condition of the safety outputs for as long as the safety guard is open.
  • Page 5: Technical Data

    For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 3 Technical Data General data Standards...
  • Page 6 Number of semi-conductor outputs with signaling function Number of fail-safe digital outputs Safety classification Standards EN ISO 13849-1 EN IEC 61508 Performance Level, up to Category PFH value 2.70 x 10⁻¹⁰ /h PFD value 2.10 x 10⁻⁵ Safety Integrity Level (SIL), suitable for applications in Mission time 20 Year(s) Mechanical data...
  • Page 7 Termination Cable (Y-UL 2517), 8-pole Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current Note (series-wiring) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD Length of cable Cable section, maximum 8 x 0.35 mm²...
  • Page 8 Degree of pollution Electrical data Operating voltage 24 VDC -15 % / +10 % Operating current, minimum 0.5 mA No-load supply current I , maximum 35 mA Rated operating voltage 24 VDC Operating current 600 mA Required rated short-circuit current 100 A Switching frequency, maximum 1 Hz...
  • Page 9 Classification ZVEI CB24I, Source Classification ZVEI CB24I, Sink Electrical data - Diagnostic outputs Designation, Diagnostic outputs Design of control elements short-circuit proof, p-type Voltage drop U , maximum Voltage, Utilisation category DC-12 24 VDC Current, Utilisation category DC-12 0.05 A Voltage, Utilisation category DC-13 24 VDC Current, Utilisation category DC-13...
  • Page 10: Mounting

    This device complies with the nerve stimulation limits (ISED CNR-102) when operated at a minimum distance of 100 In the event of changes or modifications that have not been expressly approved by K.A. Schmersal GmbH & Co. KG, the user's authorisation to use the device may become ineffective.
  • Page 11: Dimensions

    The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads). 4.2 Dimensions All measurements in mm. Safety sensor Actuator Alternative suitable actuators with different design: refer to products.schmersal.com.
  • Page 12: Accessories

    4.3 Accessories Set of disposable screws (order separately) - 4x M4x25 incl. washers, order number 101217746 - 4x M4x30 incl. washers, Bestellnummer 101217747 Sealing kit (order separately) - Order number 101215048 - 8 plugs and 4 under seals - To seal the mounting holes and as a spacer (approx. 3 mm) to facilitate cleaning below the mounting surface - Also suitable as tamper protection for the screw attachment 4.4 Switch distance Switching distances in mm to IEC 60947-5-3...
  • Page 13: Adjustment

    Switching distances in mm to IEC 60947-5-3 Actuator RST Actuator RST V2 Sensor RSS  Sensor RSS V2 With the combination of "old sensor - new actuator (V2)" there may be limitations in availability owing to the reduced s mm). This change has no affect on the performance level. The side allows for a maximum height misalignment (X) of sensor and actuator of ±...
  • Page 14: Electrical Connection

    Requirements for the connected safety-monitoring module: dual-channel safety input, suitable for p-type sensors with NO function Information for the selection of suitable safety-monitoring modules can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
  • Page 15: Serial Diagnostic -Sd

    For convenient wiring and series-wiring of SD components, the SD junction boxes PFB-SD-4M12-SD (variant for the field) and PDM-SD-4CC-SD (variant for control cabinet on carrier rail) are available along with additional comprehensive accessories. Detailed information is available on the Internet, products.schmersal.com. 5.3 Wiring examples for series-wiring Series-wiring can be set up.
  • Page 16: Wiring Configuration And Connector Accessories

    Y1 and Y2 = Safety outputs → Safety monitoring module SD-IN → Gateway → Field bus 5.4 Wiring configuration and connector accessories Function safety switchgear Pin configuration of the Colour codes of the Schmersal Poss. connector connectors colour codes of...
  • Page 17: Actuator Coding

    Connecting cables with coupling (female) IP67 / IP69, M12, 8-pole - 8 x 0.25 mm² to DIN 47100 Cable length Ordering code 2,5 m 103011415 5,0 m 103007358 10,0 m 103007359 15,0 m 103011414 Connecting cables with coupling (female) IP69K, M12, 8-pole - 8 x 0,21 mm² Cable length Ordering code 5,0 m...
  • Page 18: Working Principle And Diagnostic Function

    7 Working principle and diagnostic function 7.1 Mode of operation of the safety outputs The safety outputs can be integrated into the safety circuit of the control system. The opening of a safety guard, i.e. the actuator is removed out of the active zone of the sensor, will immediately disable the safety outputs of the sensor.
  • Page 19 Error Errors which no longer guarantee the function of the safety switchgear (internal errors) cause the safety outputs to be disabled within the duration of risk. After fault rectification, the error message is reset by opening and re-closing the corresponding safety guard. Error warning A fault that does not immediately endanger the safety function of the safety switchgear (e.g.
  • Page 20: Safety-Sensors With Serial Diagnostic Function

    Table 1: Examples of the diagnostic function of the safety-sensor with conventional diagnostic output Sensor function LED's Diagnostic- Safety Comments output outputs green yellow   Y1, Y2   Supply voltage Voltage on, no evaluation of the voltage quality actuated 24 V 24 V The yellow LED always signals...
  • Page 21 Gateway is integrated as a slave in an existing field bus system. In this way, the diagnostic signals can be evaluated by means of a PLC. The necessary software for the integration of the SD-Gateway is available for download at products.schmersal.com. The response data and the diagnostic data are automatically and permanently written in the assigned input byte of the PLC for each safety sensor in the series-wired chain.
  • Page 22 Table 2: Function of the visual diagnostic LEDs, the serial status signals and the safety outputs by means of an example System LED's Safety Status signals serial diagnostic byte Bit n° conditio outputs green yellow Y1, Y2 Non- actauted , inputs X1 and enabled Actuated...
  • Page 23: Set-Up And Maintenance

    Table 3: Tabular overview of status signals, warnings or error messages(The described condition is reached, when Bit = 1) Communication directions: Request byte: from the PLC to the local safety sensor   Response byte: from the local safety sensor to the PLC  ...
  • Page 24: Disassembly And Disposal

    9 Disassembly and disposal 9.1 Disassembly The safety switchgear must be disassembled in a de-energised condition only. 9.2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and £ legislations.