Questions, problems, missing parts? Before returning to the store,
call Commercial Electric Customer Service
8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m., EST, Saturday
1-877-527-0313
HOMEDEPOT.COM
THANK YOU
We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this circuit tester. We strive to continually create
quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for
Summary of Contents for Commercial Electric DUALCHECK CE-VD7504GFI
Page 1
THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this circuit tester. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for...
Table of Contents Table of Contents............... 2 Operation ................ 4 Safety Information ............2 Installing or Replacing the Battery ........7 Warranty ................. 2 Care and Cleaning ............. 7 Pre-Operation ..............3 Product Description ..............3 Product Specifications.............. 3 Safety Information Please read this manual carefully and pay attention to related safe working standards before using this tester.
Pre-Operation PRODUCT DESCRIPTION Part Description Quantity GFCI test button Circuit indicator LED panel Speaker Non-contact voltage (NCV) detection button NCV LED indicator NCV test probe PRODUCT SPECIFICATIONS Component Specification Operating range 115 - 125 VAC, 50-60 Hz (circuit tester) and 50 - 600 VAC, 50-60 Hz (NCV detection) Certification and Compliance Conforms to UL 1436 (circuit tester) UL 61010-1 &...
Operation Testing an outlet circuit NOTICE: All appliances or equipment on the circuit being tested should be unplugged to help avoid erroneous readings. NOTICE: This is not a comprehensive diagnostic instrument but a simple instrument to detect nearly all probable common improper wiring conditions.
Page 5
Operation (continued) Testing GFCI protected outlets CAUTION: GFCIs are sometimes installed in 2- wire systems (no ground wire available). This may or may not meet the local code. This tester will not trip GFCI outlets installed without a ground wire. On 2-wire systems, use the Test and Reset buttons on the GFCI outlet to demonstrate proper operation.
Page 6
Operation (continued) Testing non-contact voltage (NCV) NOTICE: Static Electricity – The tester is subject to electrical static interference. If the LED or tone activate momentarily it is detecting static electricity. When detecting voltage the LED and tone will cycle continuously. NOTICE: NCV detection antennae interference –...
Installing or Replacing the Battery This tester comes complete with one LR44 battery in the package. When replacing, always replace with another LR44 battery. To install or replace the battery: Orient the tester backside up and use a small Phillips screwdriver to remove the battery compartment cover (marked with the battery symbol). Remove the LR44 battery.
Page 8
Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service 8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m., EST, Saturday 1-877-527-0313 HOMEDEPOT.COM Retain this manual for future use.
Need help?
Do you have a question about the DUALCHECK CE-VD7504GFI and is the answer not in the manual?
Questions and answers