Troubleshooting
The POWER indicator on the top panel does not light green.
\ Check if the power plug of the AC adaptor is disconnected from the wall outlet.
\ Check that DC IN is connected firmly with the cord from the AC adaptor.
Communication cannot be established with AN-LS1 or a projector.
When connecting AN-LS1 using serial-connection
\ Check that the RS-232C terminal of AN-LS1 and a computer or the serial port of the projector are
connected correctly.
\ Check that the RS-232C cable is a cross-over cable.
\ Check that a commercially available controller or computer is connected to the RS-232C
(CONTROLLER) terminal.
\ Check that the projector is connected to the RS-232C (PROJECTOR) terminal.
\ Check that the RS-232C port setting for AN-LS1 corresponds to the setting for the computer or the
projector.
When connecting AN-LS1 to a computer using network (LAN)-connection
\ Check that the cable's connector is firmly inserted in the 10BASE-T terminal of AN-LS1.
\ Check that the cable is firmly inserted into a LAN port for a computer or a network device such as
a hub.
\ Check that the LAN cable is a Category 5 cable.
\ Check that the LAN cable is a cross-over cable when connecting AN-LS1 to a computer directly.
\ Check that the LAN cable is a straight-through cable when connecting AN-LS1 with a network
device such as a hub.
\ Check that the power supply is turned on for the network device such as a hub between AN-LS1
and a computer.
\ Check that the RS-232C (PROJECTOR) terminal and the serial port for the projector are connected
correctly.
\ Check that the RS-232C cable is a cross-over cable.
\ Check that the RS-232C port setting for AN-LS1 corresponds to the setting for the projector.
Check that Sharp COM Redirection Software is installed correctly.
1. Click "Start"
2. Double-click "System".
3. Select "Hardware" tab and click "Device Manager".
4. Double-click "Ports (COM & LPT)".
If the Sharp COM Redirection Software icon is shown, Sharp COM Redirection Software has been
installed.
If there is a yellow exclamation mark (!) or question mark (?) on the Sharp COM Redirection Software
icon, there is a possibility that the installation has failed, COM numbers are duplicated or there is a
conflict with another driver resource.
In such a case, it is necessary to delete Sharp COM Redirection Software once and then reinstall it.